Search results for " tests"
showing 10 items of 3284 documents
Impact of Proportionality of Secondary Mitral Regurgitation on Outcome After Transcatheter Mitral Valve Repair
2020
The purpose of this paper was to evaluate the impact of proportionality of secondary mitral regurgitation (SMR) in a large real-world registry of transcatheter edge-to-edge mitral valve repair (TMVr) BACKGROUND: Differences in the outcomes of recent randomized trials of TMVr for SMR may be explained by the proportionality of SMR severity to left ventricular (LV) volume.The ratio of pre-procedural effective regurgitant orifice area (EROA) to LV end-diastolic volume (LVEDV) was retrospectively assessed in patients undergoing TMVr for severe SMR between 2008 and 2019 from the EuroSMR registry. A recently proposed SMR proportionality scheme was adapted to stratify patients according to EROA/LVE…
Measurement of coagulation factors during rivaroxaban and apixaban treatment: Results from two crossover trials
2018
Abstract Background Prediction models for venous thromboembolism recurrence will likely be improved by adding levels of coagulation factors. Risk assessment is ideally performed during anticoagulant treatment, however, the influence of direct oral anticoagulants on coagulation factors is uncertain. Objective To assess the influence of rivaroxaban and apixaban on several coagulation factor levels. Methods In two crossover trials we assessed the influence of rivaroxaban and apixaban intake on factor (F)VIII, FXI and FXII‐activity and fibrinogen, von Willebrand factor (VWF:Ag), and d‐dimer levels. At three sessions with a washout period in between, blood was taken from 12 healthy male individu…
Diagnosis of Endometrial Carcinoma: Predictive Value of Transvaginal Color Doppler
1995
The objective of this study was to determine whether transvaginal ultrasound plus color Doppler flow improve the ability to diagnose endometrial carcinoma and allow better discrimination between benign and malignant endometrial lesions. One hundred thirty women with abnormal uterine bleeding were evaluated with transvaginal color Doppler before fractional dilatation and curettage (D&C). The endometrial line thickness and endometrial characteristics were evaluated by endosonography. The resistive and pulsatile indices of the uterine arteries and of the endometrium were evaluated with transvaginal color Doppler. Following D&C and tissue diagnosis, women were divided into two groups, 62 with a…
Intravenous thrombolysis for acute ischaemic stroke in patients on direct oral anticoagulants.
2018
BACKGROUND AND PURPOSE Whereas intravenous thrombolysis (IVT) is allowed for acute ischaemic stroke in patients on vitamin K antagonists with international normalized ratio ≤1.7, there are no similar recommendations for patients on direct oral anticoagulants (DOACs), notably due to the lack of coagulation tests to assess the therapeutic effects. Although the literature is scarce, consisting of small case series and retrospective studies, considering the frequency of this situation the French Vascular Neurology Society and the French Study Group on Haemostasis and Thrombosis have worked on a joint position paper to provide a practical position regarding the emergency management of ischaemic …
Newborn hearing-screening project using transient evoked otoacoustic emissions: western sicily experience
2006
Summary Objective To study the incidence of congenital sensorineural hearing loss in all newborns introducing a screen test with a protocol no expensive, with a good “screen sensitivity” that could let an earlier identification of hearing impairment beginning early intervention by 2 months of age and increasing the probability of having language development within the normal range of development. Methods The study was conducted in Sciacca hospital from the beginning of 2003 to our days and was carried out with transient evoked otoacoustic emission using the criteria for PASS or RETEST and considering eventual prenatal and perinatal risk factors. All the newborns were divided into four group…
The QRS narrowing index for easy and early identification of responder to cardiac resynchronization therapy.
2013
The rationale for cardiac resynchronization therapy (CRT) in patients with heart failure (HF) is based on the possibility of inducing substantial left ventricular reverse remodeling. It is well known that some of these patients don't benefit from this therapy (the so-called non-responders) [1,2]. No better predictors of a positive answer to CRT than pre-CRT QRS duration (QRSd) were found [3,4]. The aim of our study was to identify a parameter for an easy and early identification of responders to CRT. In this regard, according to Rickard et al., we identified and observed QRS index (QI), as an expression of electrical remodeling after CRT, and its relation with anatomic reverse remodeling, e…
Importance of Residual Renal Function in Continuous Ambulatory Peritoneal Dialysis: Its Influence on Different Parameters of Renal Replacement Treatm…
1999
<i>Objective:</i> To study the influence of residual renal function (RRF) on different parameters of the renal substitutive treatment offered by peritoneal dialysis. <i>Methods:</i> We analyzed the impact of RRF on dialysis dose, nutrition parameters, anemia and phosphocalcic metabolism in 37 patients with end-stage renal disease (ESRD) treated by continuous ambulatory peritoneal dialysis (CAPD). Analytical controls were done every 6 months after an initial assessment at the end of the first month of treatment. Multiple lineal regression models were used as the statistical method to analyze the influence of RRF on different theoretically dependent factors. RRF was ca…
F9 missense mutations impairing factor IX activation are associated with pleiotropic plasma phenotypes.
2022
Background Circulating dysfunctional factor IX (FIX) might modulate distribution of infused FIX in hemophilia B (HB) patients. Recurrent substitutions at FIX activation sites (R191-R226, >300 patients) are associated with variable FIX activity and antigen (FIXag) levels. Objectives To investigate the (1) expression of a complete panel of missense mutations at FIX activation sites and (2) contribution of F9 genotypes on the FIX pharmacokinetics (PK). Methods We checked FIX activity and antigen and activity assays in plasma and after recombinant expression of FIX variants and performed an analysis of infused FIX PK parameters in patients (n = 30), mostly enrolled in the F9 Genotype and PK HB …
Variation of platelet function in clinical phenotypes of acute venous thromboembolism – Results from the GMP‐VTE project
2022
Background The role of platelets in the pathogenesis of venous thromboembolism (VTE) is receiving increasing attention; however, limited information is available on platelet function in the acute phase of the disease. Objective To characterize platelet function according to VTE phenotypes. Patients/Methods In total, 154 subjects (isolated pulmonary embolism [iPE], n = 28; isolated deep vein thrombosis [iDVT], n = 35; DVT+PE, n = 91) were included. In this study platelet function analyzer (PFA)-200, light transmission aggregometry (LTA), thrombin generation (TG) in presence (PRP) and absence (PFP) of platelets and platelet flow cytometry were investigated. LASSO regression was used to select…
Diagnostic Accuracy of a New Antigen Test for SARS-CoV-2 Detection
2021
Background and aims: Quick and reliable diagnostic tools play an important role in controlling the spread of the SARS-Cov-2 pandemic. The aim of this study was to evaluate the diagnostic accuracy of a new cyto-salivary antigen test aimed at detecting the presence of antigens for SARS-CoV-2, as compared by the gold standard RT-PCR and a lateral flow test. Methods: A total of 433 healthy volunteers were enrolled in the study and the sensitivity and specificity of the new cyto-salivary antigen test were calculated, as compared to the RT-PCR nasopharyngeal swab and to the lateral flow test. Results: A total of 433 samples were collected and tested at the Mediterranean Fair in Palermo from Febru…