Search results for " tomography"

showing 10 items of 1487 documents

Central correlation of muscle sympathetic nerve activation during baroreflex unloading - a microneurography-positron emission tomography study

2013

The baroreceptor reflex controls spontaneous fluctuations in blood pressure. One major control variable of the baroreflex is the sympathetic vasoconstrictor activity to muscles [MSNA; burst frequency (BF) and burst incidence (BI)], which can be quantitatively assessed by microneurography. We aimed to investigate the central regions involved in baroreflex regulation of MSNA. Healthy men (mean age 25 years) participated in three experimental sessions. (i) Microneurography recordings of MSNA from the left peroneal nerve during rest and baroreflex unloading, induced by lower body negative pressure (LBNP; -40 mmHg). If MSNA could be reliably recorded throughout this procedure (n = 15), the subje…

AdultMaleBaroreceptorbusiness.industryGeneral NeuroscienceBrainPeroneal NerveRostral ventrolateral medullaMicroneurographyBaroreflexBaroreflexGlucoseBlood pressureOrgan SpecificityPositron-Emission TomographyAnesthesiaMedulla oblongataHumansMedicineBrainstemMuscle SkeletalbusinessMedullaEuropean Journal of Neuroscience
researchProduct

Ocular biometric repeatability using a new high-resolution swept-source optical coherence tomographer.

2020

To assess the repeatability of ocular biometric parameters using a high-resolution imaging device.74 healthy right eyes were included in this study. Five-repeated measurements were taken with ANTERION high-resolution swept-source optical coherence tomographer (SS-OCT) to measure: corneal thickness (central and at 2, 4 and 6-mm diameters), aqueous depth (AD), lens thickness (LT), anterior chamber volume (ACV), axial length (AL), and pupil (diameter and position). The intrasubject standard deviation (SWe have not found statistically significant differences between repeated measurements (p  0.05). The mean difference for corneal thickness was between -0.08 and 0.28 μm. For AD and LT was 0.004 …

AdultMaleBiometrygenetic structuresBiometricsComputer scienceAnterior ChamberBiomedical EngineeringHigh resolution030204 cardiovascular system & hematologyEye03 medical and health sciencesYoung Adult0302 clinical medicineOpticsOptical coherence tomographyLens CrystallinemedicineHumansAgedmedicine.diagnostic_testbusiness.industryReproducibility of ResultsPupilGeneral MedicineCoherence (statistics)RepeatabilityMiddle Agedeye diseasesSurgeryFemalesense organsbusiness030217 neurology & neurosurgeryTomography Optical CoherenceExpert review of medical devices
researchProduct

Differential contributions of ankle plantarflexors during submaximal isometric muscle action: A PET and EMG study

2014

Abstract The objective of this study was to investigate the relative contributions of superficial and deep ankle plantarflexors during repetitive submaximal isometric contractions using surface electromyography (SEMG) and positron emission tomography (PET). Myoelectric signals were obtained from twelve healthy volunteers (27.3±4.2yrs). A tracer ([ 18 F]-FDG) was injected during the exercise and PET scanning was done immediately afterwards. The examined muscles included soleus (Sol), medial gastrocnemius (MG), lateral gastrocnemius (LG), and flexor hallucis longus (FHL). It was found that isometric maximal voluntary contraction (MVC) force, muscle glucose uptake (GU) rate, and SEMG of variou…

AdultMaleBiophysicsNeuroscience (miscellaneous)Isometric exerciseElectromyographyYoung AdultMuscle actionIsometric ContractionHealthy volunteersmedicineHumansExercise physiologyMuscle Skeletalta315ExerciseLegArthrometry Articularmedicine.diagnostic_testElectromyographybusiness.industryBiomechanicsAnatomymusculoskeletal systemMagnetic Resonance ImagingHealthy VolunteersGlucosemedicine.anatomical_structureFlexor hallucis longusPositron-Emission TomographyFemaleNeurology (clinical)AnkleAnklebusinessNuclear medicineJournal of Electromyography and Kinesiology
researchProduct

Use of autologous tooth-derived graft material in the post-extraction dental socket. Pilot study

2019

Background The objectives of the present pilot study are to compare via CBCT the alveolar contraction suffered both vertically and horizontally between the control group and the group using autologous dental material (ADM), as well as to study the densitometric differences between both post-extraction sockets. Material and Methods A split-mouth study was performed in n = 9 patients who required two extraction of single-rooted teeth deemed suitable for deferred rehabilitation with osseointegrated implants. Two groups were formed — a control group, in which the post-extraction socket was not filled, and an ADM group, in which the alveolar defect was filled with freshly processed autogenous de…

AdultMaleBone densityDentistryPilot Projects02 engineering and technologyOsseointegration03 medical and health sciences0302 clinical medicineHumansMedicineTooth SocketAutograftsGeneral DentistryDental alveolusSocket preservationbusiness.industryResearch030206 dentistryCone-Beam Computed TomographyMiddle Aged:CIENCIAS MÉDICAS [UNESCO]021001 nanoscience & nanotechnologyOtorhinolaryngologyCoronal planeUNESCO::CIENCIAS MÉDICASDentinTooth ExtractionFemaleSurgeryOral Surgery0210 nano-technologybusinessMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Somatostatin-receptor scintigraphy in Graves' disease: reproducibility and variance of orbital activity.

2000

Somatostatin-receptor (SSTR) scintigraphy using the single photon emission computed tomography (SPECT) technique allows the assessment of orbital inflammation in patients with Graves' disease. Previous studies showed differences in orbital octreotide uptake already 4 hr after injection. In this study, analysis of inter-/intra-observer variance and reproducibility in the evaluation of orbital SPECT images was performed. First, SPECT data of one representative female patient with clinically active Graves' ophthalmopathy (GO), obtained 4 hr after intravenous injection of 110 MBq 111In-pentetreotide and processed by filtered backprojection, were analyzed. Transverse SPECT images were reconstruc…

AdultMaleCancer ResearchGraves' diseaseSingle-photon emission computed tomographyScintigraphyCorrelationSpearman–Brown prediction formulamedicineHumansRadiology Nuclear Medicine and imagingAgedPharmacologyObserver VariationTomography Emission-Computed Single-PhotonReproducibilitymedicine.diagnostic_testbusiness.industryIndium RadioisotopesReproducibility of ResultsGeneral MedicineVariance (accounting)Middle Agedmedicine.diseaseGraves DiseaseOncologyFemaleTomographybusinessNuclear medicineSomatostatinOrbitCancer biotherapyradiopharmaceuticals
researchProduct

Pneumonia in Febrile Neutropenic Patients and in Bone Marrow and Blood Stem-Cell Transplant Recipients: Use of High-Resolution Computed Tomography

1999

PURPOSE: To obtain statistical data on the use of high-resolution computed tomography (HRCT) for early detection of pneumonia in febrile neutropenic patients with unknown focus of infection. MATERIALS AND METHODS: One hundred eighty-eight HRCT studies were performed prospectively in 112 neutropenic patients with fever of unknown origin persisting for more than 48 hours despite empiric antibiotic treatment. Fifty-four of these studies were performed in transplant recipients. All patients had normal chest roentgenograms. If pneumonia was detected by HRCT, guided bronchoalveolar lavage was recommended. Evidence of pneumonia on chest roentgenograms during follow-up and micro-organisms detected…

AdultMaleCancer ResearchHigh-resolution computed tomographymedicine.medical_specialtyNeutropeniamedicine.medical_treatmentHematopoietic stem cell transplantationNeutropeniaFever of Unknown OriginPredictive Value of TestsmedicineHumansProspective StudiesFever of unknown originLungAgedBone Marrow TransplantationAged 80 and overmedicine.diagnostic_testbusiness.industryRespiratory diseaseHematopoietic Stem Cell TransplantationPneumoniaMiddle Agedrespiratory systemmedicine.diseaserespiratory tract diseasesSurgeryLeukemia Myeloid AcutePneumoniaBronchoalveolar lavageOncologyFemaleRadiologyTomography X-Ray ComputedComplicationbusinessBronchoalveolar Lavage FluidAlgorithmsJournal of Clinical Oncology
researchProduct

[18F]5-fluoro-2-deoxyuridine-PET for imaging of malignant tumors and for measuring tissue proliferation

2003

The nucleoside 5-fluoro-2-deoxyuridine is a pyrimidine analogue accumulating in proliferative cells. We prospectively evaluated biodistribution of the PET tracer [(18)F]5-fluoro-2-deoxyuridine (FdUrd), its value for imaging malignant tumors, and its correlation to both [(18)F]2-fluoro-2-deoxyglucose (FDG)-PET findings and histological proliferation indices. In 11 previously untreated patients (5 lung carcinoma; 3 soft tissue sarcoma; 2 gastrointestinal carcinoma; 1 non-Hodgkin lymphoma [NHL]), mean doses of 290 MBq FdUrd and 390 MBq FDG were administered intravenously on subsequent days. Static PET scans were initiated 50-70 min after administration and the mean standardized uptake values (…

AdultMaleCancer ResearchPathologymedicine.medical_specialtyLung NeoplasmsProliferation indexUrinary BladderKidneyBone and BonesPyrimidine analogueFluorodeoxyglucose F18NeoplasmsmedicineCarcinomaHumansTissue DistributionRadiology Nuclear Medicine and imagingProspective StudiesAgedGastrointestinal NeoplasmsNeoplasm StagingPharmacologymedicine.diagnostic_testbusiness.industryLymphoma Non-HodgkinSoft tissue sarcomaKidney metabolismSarcomaGeneral MedicineMiddle Agedmedicine.diseaseLymphomaKi-67 AntigenLiverOncologyPositron emission tomographyFemaleSarcomaRadiopharmaceuticalsbusinessNuclear medicineCell DivisionTomography Emission-Computed
researchProduct

High opiate receptor binding potential in the human lateral pain system

2005

To determine how opiate receptor distribution is co-localized with the distribution of nociceptive areas in the human brain, eleven male healthy volunteers underwent one PET scan with the subtype-nonselective opioidergic radioligand [(18)F]fluoroethyl-diprenorphine under resting conditions. The binding potential (BP), a parameter for the regional cerebral opioid receptor availability, was computed using the occipital cortex as reference region. The following regions of interest (ROIs) were defined on individual MR images: thalamus, sensory motor strip (SI/MI area), frontal operculum, parietal operculum, anterior insular cortex, posterior insular cortex, anterior cingulate cortex (ACC; peri-…

AdultMaleCingulate cortexCognitive NeuroscienceThalamusCaudate nucleusDiprenorphinePainInsular cortexbehavioral disciplines and activitiesCortex (anatomy)medicineHumansOperculum (brain)Anterior cingulate cortexbusiness.industryPutamenBrainNociceptorsAnatomyMiddle AgedMagnetic Resonance Imagingmedicine.anatomical_structurenervous systemNeurologyPositron-Emission TomographyReceptors Opioidbusinesspsychological phenomena and processesNeuroImage
researchProduct

Accuracy between virtual surgical planning and actual outcomes in orthognathic surgery by iterative closest point algorithm and color maps: A retrosp…

2018

Background To evaluate the accuracy between actual outcomes and virtual surgical planning (VSP) in orthognathic surgery regarding the use of three-dimensional (3D) surface models for registration using iterative closest point (ICP) algorithm and generated color maps. Material and Methods Construction of planning and postoperative 3D models in STL files format (M0 and M1, respectively) from CBCT of 25 subjects who had been submitted to bimaxillary orthognathic surgery was performed. M0 and M1 were sent to Geomagic software in semi-automatic alignment surface mesh order of M0 and M1 for registration using ICP algorithm to calculate mean deviation (MD, MD+, MD-, SD) and root mean square (RMS –…

AdultMaleComputer sciencemedicine.medical_treatmentOrthognathic surgery3d modelMandibleNoseSurgical planningPatient Care PlanningRoot mean square03 medical and health sciencesImaging Three-Dimensional0302 clinical medicineSoftwareMaxillamedicineHumansGeneral DentistryRetrospective StudiesReproducibilityOrthognathic Surgical Proceduresbusiness.industryResearchOrthognathic SurgeryReproducibility of ResultsIterative closest pointRetrospective cohort study030206 dentistryCone-Beam Computed Tomography:CIENCIAS MÉDICAS [UNESCO]Treatment OutcomeSurgery Computer-AssistedOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASComputer-Aided DesignFemaleSurgeryOral SurgerybusinessAlgorithmAlgorithmsMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Evaluation of texture analysis for the differential diagnosis of focal nodular hyperplasia from hepatocellular adenoma on contrast-enhanced CT images

2018

PurposeTo explore the value of CT texture analysis (CTTA) for differentiation of focal nodular hyperplasia (FNH) from hepatocellular adenoma (HCA) on contrast-enhanced CT (CECT).MethodsThis is a retrospective, IRB-approved study conducted in a single institution. A search of the medical records between 2008 and 2017 revealed 48 patients with 70 HCA and 50 patients with 62 FNH. All lesions were histologically proven and with available pre-operative CECT imaging. Hepatic arterial phase (HAP) and portal venous phase (PVP) were used for CTTA. Textural features were extracted using a commercially available research software (TexRAD). The differences between textural parameters of FNH and HCA wer…

AdultMaleComputer tomographyAdolescentEnhanced ctUrologyContrast MediaLogistic regressionAdenoma Liver Cell030218 nuclear medicine & medical imagingDiagnosis DifferentialYoung Adult03 medical and health sciences0302 clinical medicineFocal nodular hyperplasiamedicineHumansRadiology Nuclear Medicine and imagingBinary logistic regression analysisTexture analysiRetrospective StudiesRadiological and Ultrasound Technologybusiness.industryLiver NeoplasmsGastroenterologyFocal nodular hyperplasiaMiddle AgedHepatocellular adenomaImage Enhancementmedicine.diseaseHepatocellular adenomaLiver030220 oncology & carcinogenesisMann–Whitney U testKurtosisFemaleDifferential diagnosisTomography X-Ray ComputedSettore MED/36 - Diagnostica Per Immagini E RadioterapiabusinessNuclear medicineAbdominal Radiology
researchProduct