Search results for " tomography"
showing 10 items of 1487 documents
Case Report: Unmasking Hypercalcemia in Patients With Neuroendocrine Neoplasms. Experience From Six Italian Referral Centers
2021
BackgroundHypercalcemia is a common paraneoplastic syndrome which can occur in up to 10% of patients with advanced neoplasms. Paraneoplastic parathyroid hormone-related protein (PTHrP) represents the most frequent cause of this syndrome. In neuroendocrine neoplasms (NENs) paraneoplastic hypercalcemia is rare.Case SeriesThe present series includes all patients with NENs and paraneoplastic hypercalcemia from four Italian centres: (I) A 40-year-old man was hospitalized for repeated episodes of falls, hyposthenia and drowsiness. Severe hypercalcemia was found. Metastatic pancreatic G2 NEN and PTHrP-related hypercalcemia were diagnosed. The patient started therapy with somatostatin analogs (SSA)…
Monitoring bone growth using quantitative ultrasound in comparison with DXA and pQCT.
2008
Quantitative ultrasound (QUS) is a safe, inexpensive, and nonradiation method for bone density assessment. QUS correlates with, and predicts fragility fractures comparable to, dual-energy X-ray absorptiometry (DXA)-derived bone mineral density (BMD) in postmenopausal women. However, its validity in monitoring bone growth in children is not well understood. Two hundred and fifty-eight 10-13 yr pubertal girls and 9 37-43 yr adults without diseases or history of medications known to affect bone metabolism were included in the 2-yr prospective study. Calcaneal broadband ultrasound attenuation (cBUA) was assessed using QUS-2 (Quidel, Santa Clara, CA), speed of sound of tibial shaft (tSOS) using …
Both Resistance and Agility Training Increase Cortical Bone Density in 75- to 85-Year-Old Women With Low Bone Mass
2004
A randomized, controlled, single-blinded 25-wk prospective study was conducted to compare the effects of group-based resistance and agility training on bone, as measured by both dual-energy X-ray absorptiometry (DXA) and peripheral quantitative computed tomography (pQCT), in older women with low bone mass. Ninety-eight community-dwelling women aged 75-85 yr were randomized to one of three experimental groups: resistance training (n = 32), agility training (n = 34), or stretching (sham exercise) (n = 32). Total hip, femoral neck, and trochanteric bone mineral density (BMD) were measured by DXA. Peripheral QCT measurements were performed at the tibia and radius. The pQCT outcome measures at t…
Computed tomography assessment of temporomandibular joint position and dimensions in patients with class II division 1 and division 2 malocclusions
2016
Background This study aimed to investigate and compare the positions and dimensions of the temporomandibular joint and its components, respectively, in patients with Class II division 1 and division 2 malocclusions. Material and methods Computed tomography images of 14 patients with Class II division 1 and 14 patients with Class II division 2 malocclusion were included with a mean age of 11.4 ± 1.2 years. The following temporomandibular joint measurements were made with OsiriX medical imaging software program. From the sagittal images, the anterior, superior, and posterior joint spaces and the mandibular fossa depths were measured. From the axial images, the greatest anteroposterior and med…
Arthroscopic approach for treating a pigmented villonodular sinovitis of TMJ. A case report
2017
The present report describes the case of a 29-year-old man referred to our service for TMJ pain and progressive reduction of the mouth opening. Differential diagnostics included rheumatologic diseases, monoarthritis and intraarticular lumps. In this line, a face CT scan and a MRI of TMJ were carried out in order to ensure a proper diagnosis. These tests showed a solid lesion into the joint cavity. In view of that, we decided to perform a diagnostic and therapeutic arthroscopy of TMJ. Histopathological studies confirmed the diagnosis of pigmented villonodular synovitis. The main aim of this report is to describe this rare syndrome with the goal of proposing suitable treatments. Moreover, we …
Vergleich radiologischer Verfahren zur präoperativen Beurteilung der Verankerungsfestigkeit von Wirbelsäulenimplantaten
1997
PURPOSE To compare three techniques with regards to their ability to estimate pull out strength of spinal fusion hardware. MATERIAL AND METHODS VDS-screw fixation strength in 50 human cadaveric vertebral bodies was approximated by means of pull out force measurement. Bone quality was assessed by Dual X-ray Absorptiometry (DXA). Quantitative Computed Tomography (QCT) and T2*-relaxation time. For each of these techniques, correlation with axial pull out force strength was investigated. RESULTS Highest correlation was found for cancellous bone density measured by QCT (r = 0.72; p < 0.001). Immediately followed by DXA (r = 0.70; p < 0.001), which involves all bone components. Inverted T2*-relax…
Influence of Drilling Technique on the Radiographic, Thermographic, and Geomorphometric Effects of Dental Implant Drills and Osteotomy Site Preparati…
2020
The aim of this comparative study is to analyze the influence of drilling technique on the radiographic, thermographic, and geomorphometric effects of dental implant drills and osteotomy site preparations. One hundred and twenty osteotomy site preparations were performed on sixty epoxy resin samples using three unused dental implant drill systems and four drilling techniques performed with a random distribution into the following study groups: Group A: drilling technique performed at 800 rpm with irrigation (n = 30)
Uso de la tomografía computarizada en el diagnóstico de la anquilosis de la articulación temporomandibular: Presentación de dos casos clínicos
2006
La anquilosis de la articulación temporomandibular es definida como la abolición o limitación de los movimientos de dicha articulación. Radiográficamente la anquilosis demuestra aspectos bien característicos que facilitan el diagnóstico, sin embargo, su análisis en las técnicas radiográficas convencionales, en la mayoría de las veces, no se presenta de forma clara. Con la evolución de las técnicas radiográficas, la tomografía computarizada pasó a ser un examen de gran importancia en el diagnóstico de las anquilosis temporomandibulares. En vista de ello, el presente trabajo se propone mostrar y describir imágenes tomográficas de la anquilosis de esta articulación, presentando dos casos clíni…
Bestimmung der Knochenqualität vor Wirbelsäuleninstrumentation - Stellenwert verschiedener in vivo-Methoden
2008
OBJECTIVE: The present investigation should elucidate which assessment technique for bone quality is most appropriate to estimate preoperatively fixation strength of instrumental spine fusions. METHODS: VDS-screw fixation strength in 50 human cadaveric vertebral bodies was approximated by means of pullout force assessment. Bone quality was assessed by Dual Energy X-ray Absorptiometry (DEXA), Quantitative Computed Tomography (QCT), MRT and histomorphometry. For each of these techniques, correlation with axial pull out force strength was investigated. RESULTS: Highest correlation was found for cancellous bone density (QCT) (r = 0.72; p < 0.001) and DEXA (r = 0.70; p < 0.001). MRT, cortical bo…
Coronary Stent Strut Fractures: Classification, Prevalence and Clinical Associations
2021
Introduction. The frequency, characteristics and clinical implications of Strut fractures (SFs) remain incompletely understood. Methods and results. A total of 185 (160 patients) newer-generation drug-eluting stents (DES) were imaged. SFs were found in 21 DES (11.4%) and were classified in four patterns: one single stacked strut (41%)