Search results for " topography"
showing 10 items of 102 documents
Transconjunctival sutureless 25-Gauge versus 20-Gauge standard vitrectomy: correlation between corneal topography and ultrasound biomicroscopy measur…
2009
Purpose: To determine the correlation between corneal shape changes and ultrasound biomicroscopy (UBM) findings at the sclerotomy sites in conventional 20-gauge (G) pars plana vitrectomy (PPV) and 25-G transconjunctival sutureless vitrectomy (TSV) and to compare the effectiveness of the two surgical methods. Design: Prospective, comparative, observational case series. Methods: Sixty consecutive eyes (60 patients) undergoing primary 3-port PPV. Thirty eyes (30 patients, group 20-G) were treated with 20-G standard PPV and 30 eyes (30 patients, group 25-G) with 25-G TSV. We compared healing of the sclerotomy sites in the two groups. We determined the correlation between corneal shape changes (…
Optical characterization of Mg-doped GaN films grown by metalorganic chemical vapor phase deposition
2000
Scanning electron microscopy, micro-Raman, and photoluminescence (PL) measurements are reported for Mg-doped GaN films grown on (0001) sapphire substrates by low-pressure metalorganic chemical vapor phase deposition. The surface morphology, structural, and optical properties of GaN samples with Mg concentrations ranging from 1019 to 1021 cm−3 have been studied. In the scanning micrographs large triangular pyramids are observed, probably due to stacking fault formation and three-dimensional growth. The density and size of these structures increase with the amount of magnesium incorporated in the samples. In the photoluminescence spectra, intense lines were found at 3.36 and 3.31 eV on the tr…
Repeatability of whole-cornea measurements using a new swept-source optical coherence tomographer
2020
Purpose: The aim of this study was to evaluate the repeatability of several corneal parameters provided by a high-resolution swept-source optical coherence tomographer (SS-OCT). Methods: One eye from each of 74 patients was measured five times consequently using the ANTERION SS-OCT. The following corneal parameters were analyzed: average, steep and flat keratometry (K), astigmatism for anterior, posterior and total at 3-mm, average K and astigmatism at 6-mm, anterior and posterior eccentricity, higher-order aberrations (HOA) and spherical aberration ([Formula: see text]), and anterior and posterior best-fit sphere at 8-mm. The intrasubject standard deviation (Sw), coefficient of variation (…
Soil water erosion on Mediterranean vineyards: A review
2016
Soil water erosion on cultivated lands represents a severe threat to soil resources in the world, and especially in Mediterranean areas, due to their topographic, edaphic and climatic conditions. Among the cultivated lands, vineyards deserve a particular attention because, aside representing one of the most important crops in terms of income and employment, they also have proven to be the form of agricultural use that causes one of the highest soil losses. Although the topic of soil water erosion on vineyards has been studied, it still raises uncertainties, due to the high variability of procedures for data acquisition, which consists into different scales of analysis and measurement method…
Short-Term Changes in Light Distortion in Orthokeratology Subjects
2015
Purpose. Quantifying adaptation to light distortion of subjects undergoing orthokeratology (OK) for myopia during the first month of treatment. Methods. Twenty-nine healthy volunteers (age: 22.34 ± 8.08 years) with mean spherical equivalent refractive error −2.10 ± 0.93D were evaluated at baseline and days 1, 7, 15, and 30 of OK treatment. Light distortion was determined using an experimental prototype. Corneal aberrations were derived from corneal topography for different pupil sizes. Contrast sensitivity function (CSF) was analyzed for frequencies of 1.50, 2.12, 3.00, 4.24, 6.00, 8.49, 12.00, 16.97, and 24.00 cpd under photopic conditions. Results. Average monocular values of all light di…
Scanning tunneling microscopy and spectroscopy of Mo clusters grown on TiO2(110).
2007
Molybdenum was deposited in two steps (3 eq. ML and 1 eq. ML) on the light blue rutile TiO2 10) (1 x 1) surface at room temperature, each Mo deposition cycle being followed by an annealing up to 950-1000 K. This procedure was found to lead to formation of separated clusters having a size in very wide range (1-20 nm). Scanning tunneling microscopy showed a dependence of the cluster morphology as a function of the size. The scanning tunneling spectra of Mo clusters was studied as a function of cluster dimensions and discussed in comparison with photoelectron spectroscopy results previously obtained for homogeneous Mo films. The dI/d V curves do not display the valence band structure of deposi…
A Hydrogel Derived From Decellularized Dermal Extracellular Matrix. Biomaterials
2012
The ECM of mammalian tissues has been used as a scaffold to facilitate the repair and reconstruction of numerous tissues. Such scaffolds are prepared in many forms including sheets, powders, and hydrogels. ECM hydrogels provide advantages such as injectability, the ability to fill an irregularly shaped space, and the inherent bioactivity of native matrix. However, material properties of ECM hydrogels and the effect of these properties upon cell behavior are neither well understood nor controlled. The objective of this study was to prepare and determine the structure, mechanics, and the cell response in vitro and in vivo of ECM hydrogels prepared from decellularized porcine dermis and urinar…
GLI EFFETTI DEL DISTURBO ANTROPICO SULLA TOPOGRAFIA DEL REEF A VERMETI
2011
Intertidal vermetid reefs could be affected by many human disturbances. Using a microtopography device, the authors analysed the changes induced by the accessibility on the surface topography of the reefs. Human activities seems to be able to induce a decrease in rugosity and a surface smoothing on the outer margin of the reef. These effects are proportional to the accessibility of the site.
Modeling the past and future dynamic of the vegetation patterns at catchment scale using an ecohydrological Cellular Automata model
2014
Correlation between Topographic Parameters Obtained by Back Surface Topography Based on Structured Light and Radiographic Variables in the Assessment…
2017
<sec><title>Study Design</title><p>Optical cross-sectional study.</p></sec><sec><title>Purpose</title><p>To study the correlation between asymmetry of the back (measured by means of surface topography) and deformity of the spine (quantified by the Cobb angle).</p></sec><sec><title>Overview of Literature</title><p>The Cobb angle is considered the gold standard in diagnosis and follow-up of scoliosis but does not correctly characterize the three-dimensional deformity of scoliosis. Furthermore, the exposure to ionizing radiation may cause harmful effects particularly during the growth stage, includi…