Search results for " touch"
showing 10 items of 77 documents
Resistive communications based on neuristors
2017
Memristors are passive elements that allow us to store information using a single element per bit. However, this is not the only utility of the memristor. Considering the physical chemical structure of the element used, the memristor can function at the same time as memory and as a communication unit. This paper presents a new approach to the use of the memristor and develops the concept of resistive communication.
Microfabricated high temperature sensing platform dedicated to scanning thermal microscopy (SThM)
2018
Abstract The monitoring of heat flux is becoming more and more critical for many materials and structures approaching nanometric dimensions. Scanning Thermal Microscopy (SThM) is one of the tools available for thermal measurement at the nanoscale and requires calibration. Here we report on a micro-hotplate device made of a platinum heater suspended on thin silicon nitride (SiN) membranes integrating specific features for SThM calibration. These heated reference samples can include a localized resistive temperature sensors (RTD) or standalone platinum membranes (typically 10 × 10 μm2) on which the temperature can be measured precisely. This functional area is dedicated to (1) estimate the th…
Measurement of the activation energies of oxygen ion diffusion in yttria stabilized zirconia by flicker noise spectroscopy
2019
The low-frequency noise in a nanometer-sized virtual memristor consisting of a contact of a conductive atomic force microscope (CAFM) probe to an yttria stabilized zirconia (YSZ) thin film deposited on a conductive substrate is investigated. YSZ is a promising material for the memristor application since it is featured by high oxygen ion mobility, and the oxygen vacancy concentration in YSZ can be controlled by varying the molar fraction of the stabilizing yttrium oxide. Due to the low diameter of the CAFM probe contact to the YSZ film (similar to 10nm), we are able to measure the electric current flowing through an individual filament both in the low resistive state (LRS) and in the high r…
High transparency Bi 2 Se 3 topological insulator nanoribbon Josephson junctions with low resistive noise properties
2019
Bi$_2$Se$_3$ nanoribbons, grown by catalyst-free Physical Vapour Deposition, have been used to fabricate high quality Josephson junctions with Al superconducting electrodes. The conductance spectra (dI/dV) of the junctions show clear dip-peak structures characteristic of multiple Andreev reflections. The temperature dependence of the dip-peak features reveals a highly transparent Al/Bi$_2$Se$_3$ topological insulator nanoribbon interface and Josephson junction barrier. This is supported by the high values of the Bi$_2$Se$_3$ induced gap and of I$_c$R$_n$ (I$_c$ critical current, R$_n$ normal resistance of the junction) product both of the order of 160 $\mu$eV, a value close to the Al gap. T…
Endothelial study of iris-claw phakic lens: four year follow-up.
1998
Abstract Purpose: To study quantitative and morphometric endothelial changes in phakic eyes implanted with the Worst iris-claw lens to correct high myopia. Setting: Department of Ophthalmology, University Hospital “La Fe”, Valencia, Spain. Material and Methods: This retrospective study involved 111 phakic eyes (73 patients) implanted with the Worst iris-claw lens. Noncontact specular microscopy and computer-assisted analysis was performed preoperatively and 6 months and 1, 2, 3, and 4 years postoperatively. Results: The mean cell loss was 3.85% at 6 months, 6.59% at 1 year, 9.22% at 2 years, 11.68% at 3 years, and 13.42% at 4 years. At 2 years, the hexagonality and coefficient variation in …
Anatomical correlates of visual and tactile extinction in humans: a clinical CT scan study.
1994
The anatomical correlates of tactile and visual extinction with double simultaneous stimulation were investigated in a series of 159 patients with right brain damage caused by stroke. Forty six patients showed extinction (22 tactile, 14 visual, 10 tactile and visual). Over 50% of the patients with extinction had deep lesions, which were found in about 25% of the patients with visuospatial neglect not associated with extinction. In the patients with extinction and cortico-subcortical damage the paraventricular occipital white matter and the dorsolateral frontal cortex were most often involved. By contrast, when neglect was also present, the lesions clustered in the inferior parietal lobule. …
Minimally implicit Runge-Kutta methods for Resistive Relativistic MHD
2016
The Relativistic Resistive Magnetohydrodynamic (RRMHD) equations are a hyperbolic system of partial differential equations used to describe the dynamics of relativistic magnetized fluids with a finite conductivity. Close to the ideal magnetohydrodynamic regime, the source term proportional to the conductivity becomes potentially stiff and cannot be handled with standard explicit time integration methods. We propose a new class of methods to deal with the stiffness fo the system, which we name Minimally Implicit Runge-Kutta methods. These methods avoid the development of numerical instabilities without increasing the computational costs in comparison with explicit methods, need no iterative …
Touch or touchless?:Evaluating usability of interactive displays for persons with autistic spectrum disorders
2019
Interactive public displays have been exploited and studied for engaging interaction in several previous studies. In this context, applications have been focused on supporting learning or entertainment activities, specifically designed for people with special needs. This includes, for example, those with Autism Spectrum Disorders (ASD). In this paper, we present a comparison study aimed at understanding the difference in terms of usability, effectiveness, and enjoyment perceived by users with ASD between two interaction modalities usually supported by interactive displays: touch-based and touchless gestural interaction. We present the outcomes of a within-subject setup involving 8 ASD users…
A touchless gestural system for extended information access within a campus
2017
In the last two decades, we have witnessed a growing spread of touchless interfaces, facilitated by higher performances of computational systems, as well as the increased availability of cheaper sensors and devices. Putting the focus on gestural input, several researchers and designers used Kinect-like devices to implement touchless gestural interfaces. The latter extends the possible deployments and usage of public interactive displays. For example, wall-sized displays may become interactive even if they are unreachable by touch. Moreover, billboard-sized displays may be placed in safe cases to avoid vandalism, while still maintaining their interactivity. Finally, people with temporary or …
Touchless Interfaces For Public Displays
2016
Public displays have lately become ubiquitous thanks to the decreasing cost of such technology and public policies supporting the development of smart cities. Depending on form factor, those displays might use touchless gestural interfaces that therefore are becoming more often the subject of public and private research. In this paper, we focus on touchless interactions with situated public displays, and introduce a pilot study on comparing two interfaces: an interface based on the Microsoft Human Interface Guidelines (HIG), a de facto standard in the field, and a novel interface, designed by us. Differently from the HIG-based one, our interface displays an avatar, which does not require an…