Search results for " ultrasonic"
showing 10 items of 344 documents
Perihepatic lymph nodes and antiviral response in chronic HCV-associated hepatitis.
2003
To identify predictive factors of response to interferon alpha (IFN-alpha) plus ribavirin therapy in patients with chronic hepatitis C (CHC), the presence of lymphadenopathy (LyA) of the hepatoduodenal ligament and other variables were investigated. A total of 110 patients with histologically proven CHC were enrolled in this study. Ultrasound (US) was performed at the start and end of therapy and 6 months after stopping therapy. At baseline, LyA was present in 35 (43.7%) of 80 patients with alanine aminotransferase (ALT) values and grading was significantly higher than in the LyA-negative group. LyA was more frequent in nonresponders (nonR) than in relapsers (relR) or sustained responders (…
Analysis of Internal Jugular Vein Insufficiency—A Comparison of Two Ultrasound Methods
2006
Abstract Jugular venous valve insufficiency is a contributing factor to different pathologic conditions. For assessment of insufficiency, two ultrasound techniques have been developed, that are based on very different methodology (direct Doppler assessment versus air contrast ultrasound venography [ACUV]). This study was conducted to compare these two methods to improve comparability of existing studies and diagnostic accuracy in future studies. The function of 40 valves was determined in 20 individuals during a Valsalva maneuver. For direct Doppler assessment, valvular competence was assessed on basis of Doppler recordings, following recently established criteria. Valvular insufficiency in…
A comparison of the temporal weighting of annoyance and loudness
2009
The influence of single temporal portions of a sound on global annoyance and loudness judgments was measured using perceptual weight analysis. The stimuli were 900-ms noise samples randomly changing in level every 100 ms. For loudness judgments, Pedersen and Ellermeier [J. Acoust. Soc. Am. 123, 963-972 (2008)] found that listeners attach greater weight to the beginning and ending than to the middle of a stimulus. Qualitatively similar weights were expected for annoyance. Annoyance and loudness judgments were obtained from 12 listeners in a two-interval forced-choice task. The results demonstrated a primacy effect for the temporal weighting of both annoyance and loudness. However, a signific…
Room acoustical parameters: A factor analysis approach
2009
Abstract In this study, we determined the most representative acoustical parameters for halls intended for verbal or music audition. Our study was carried out in nine halls of different shapes and designed for different uses. We measured the impulse response at a great number of points (many more than the minimum required by the ISO 3382 norm). From a physical viewpoint, all halls are enclosed three-dimensional areas. Our work hypothesis is that objective (measurable) acoustical parameters, or a combination of such parameters, must provide the acoustical information specific to each hall and must make it possible to grade each hall. Factor analysis was used to obtain these grading parameter…
The determination of trace element concentrations in fly ash samples using ultrasound-assisted digestion followed with inductively coupled plasma opt…
2009
Abstract A method of ultrasound-assisted digestion followed by inductively coupled plasma optical emission spectrometry (ICP-OES) used for the determination of trace element (chromium, copper, lead, nickel, vanadium and zinc) concentrations in fly ash samples was developed. All the measurements were performed in robust plasma conditions. Ultrasound-assisted digestion procedures using digestion solutions of aqua regia and hydrofluoric acid (HF) resulted in recovery rates of over 80% for all the analyte elements. Ultrasound-assisted two-step digestion with digestion solutions of 6 mL of HNO3 (Step 1) and 3 mL of HNO3 + 3 mL of HF (Step 2) resulted in recovery rates of over 92% for all the ana…
Mass Accretion Processes in Young Stellar Objects: Role of Intense Flaring Activity
2014
According to the magnetospheric accretion scenario, young low-mass stars are surrounded by circumstellar disks which they interact with through accretion of mass. The accretion builds up the star to its final mass and is also believed to power the mass outflows, which may in turn have a significant role in removing the excess angular momentum from the star-disk system. Although the process of mass accretion is a critical aspect of star formation, some of its mechanisms are still to be fully understood. On the other hand, strong flaring activity is a common feature of young stellar objects (YSOs). In the Sun, such events give rise to perturbations of the interplanetary medium. Similar but mo…
Seismic and non‐invasive geophysical surveys for the renovation project of Branciforte Palace in Palermo
2020
The renovation project of the historic Branciforte Palace (16th–17th century) in Palermo (Italy) was owned by the Banco di Sicilia Foundation, with the aim for it to become a multi-purpose centre for the promotion of exhibitions and cultural events. In the context of the restoration work, a multi-methodological and non-invasive geophysical study has been carried out. The seismic characterization of the foundation soils was obtained by means of joint interpretations of a vertical seismic profile (VSP), multichannel analysis of surface waves (MASW) and horizontal to vertical spectral ratio (HVSR) microtremor analysis. The mutually constrained inversion of seismic surveys carried out with diff…
Control of Acoustical Quality of Indoor Spaces: Thorough Analysis of the Influence of Façade Typologies
2001
Building shape is of prime importance with regard to the acoustic aspects of achieving adequate indoor environmental quality. This paper presents experimental results obtained in a measurement programme carried out at CSTB, using reduced-scale models. The objectives were to identify the architectural forms of façades' best for noise mitigation, and to address the influence of façade architecture on indoor acoustic quality. Many façade typologies have been assessed in different situations involving combinations of structural and architectural elements, such as balustrades, balconies, loggias, etc. A systematic simulation of real configurations (buildings in front of one another, stacked or …
Adaptive Mid-Term Representations for Robust Audio Event Classification
2018
Low-level audio features are commonly used in many audio analysis tasks, such as audio scene classification or acoustic event detection. Due to the variable length of audio signals, it is a common approach to create fixed-length feature vectors consisting of a set of statistics that summarize the temporal variability of such short-term features. To avoid the loss of temporal information, the audio event can be divided into a set of mid-term segments or texture windows. However, such an approach requires to estimate accurately the onset and offset times of the audio events in order to obtain a robust mid-term statistical description of their temporal evolution. This paper proposes the use of…
Temporal weights in the perception of sound intensity: Effects of sound duration and number of temporal segments
2018
Loudness is a fundamental aspect of auditory perception that is closely related to the physical level of the sound. However, it has been demonstrated that, in contrast to a sound level meter, human listeners do not weight all temporal segments of a sound equally. Instead, the beginning of a sound is more important for loudness estimation than later temporal portions. The present study investigates the mechanism underlying this primacy effect by varying the number of equal-duration temporal segments (5 and 20) and the total duration of the sound (1.0 to 10.0 s) in a factorial design. Pronounced primacy effects were observed for all 20-segment sounds. The temporal weights for the five-segment…