Search results for " vein."
showing 10 items of 690 documents
PTFE mesh in renal allograft compartment syndrome.
2006
We report a case of anuria in a 42-year-old female kidney transplant patient that occurred secondary to extrinsic compression from a large kidney being placed extraperitoneally in a small iliac fossa. Prompt reexploration in the immediate postoperative period resulted in salvage of the graft with restoration of kidney function. The abdominal wall was reconstructed using prosthetic mesh, which decreased the compartment pressure within the iliac fossa sufficiently to allow the renal vein patency and the kidney perfusion. We think that this tension-free surgical technique should be applied in those cases in which the retroperitoneal space is less than the size of the kidney to avoid renal allo…
Sources of human plasma cyclic AMP. Examinations before and after beta 2 adrenergic stimulation.
1981
Plasma cyclic AMP was measured in different vessels in seventeen volunteers before and after stimulation with terbutaline. Differences between arterial blood and blood from the hepatic vein, right ventricle, inferior vena cava and a cubital vein could not be demonstrated. Only in the renal vein was the concentration of cyclic AMP decreased. Our results indicate that cyclic AMP is not generated from any specific isolated organ and that changes in cyclic AMP after subcutaneous injection of terbutaline reflect a general influence of this drug.
Bolus-enhanced renal spiral CT: technique, diagnostic value and drawbacks
1994
Abstract In addition to pre- and postcontrast renal CT scans, early bolus-enhanced spiral scans during demarcation of the corticomedullary junction were acquired in 85 patients. The diagnostic value and drawbacks of the three imaging series in the evaluation of renal disease were assessed. Renal calcifications and calculus disease detected at precontrast scans (18%) were obscured after contrast administration and excretion in most cases. In the detection of renal lesions bolus-enhanced spiral CT and delayed postcontrast scans had an identical diagnostic yield (94%). Bolus-enhanced spiral CT was superior in the assessment of lesion vascularity and vascular anatomy as well as opacification of…
Endovenous treatment of the great saphenous vein using a 1,320 nm Nd:YAG laser causes fewer side effects than using a 940 nm diode laser.
2005
Limited data are available about treatment-related side effects with respect to laser wavelength in endovenous laser treatment (ELT) of the great saphenous vein (GSV).To compare the results and side effects of a 940 nm diode and a 1,320 nm neodymium:yttium-aluminum-garnet (Nd:YAG) laser.Three patient cohorts (A, B, and C) received ELT of the GSV using a 940 nm diode laser at 15 W (group A) or 30 W (group B) or using a 1,320 nm laser at 8 W (group C). In all cases, energy was administered continuously with constant pullback of the laser fiber under perivenous tumescent local anesthesia.The GSVs of group A (n = 113), group B (n = 136), and group C (n = 33) received ELT. An average linear endo…
Diagnostic accuracy of current sonographic criteria for the detection of outflow abnormalities in the internal jugular veins
2012
Objectives: This study was aimed at evaluation of the diagnostic value of Doppler sonography for the assessment of abnormalities in the internal jugular veins (IJVs). Method: One hundred and sixteen IJVs were assessed in 58 patients with associated multiple sclerosis. Findings of Doppler sonography were compared with results of the reference test: catheter venography. Results: At least one positive extracranial sonographic criterion suggesting venous abnormality was found in 92.2% of the assessed veins. Yet, sensitivity, specificity, positive and negative predictive values of sonography were low: 93.4%, 12.0%, 79.4% and 33.3% for at least one positive criterion, and for at least two positiv…
Semi-automated retinal vessel analysis in nonmydriatic fundus photography.
2013
Purpose Funduscopic assessment of the retinal vessels may be used to assess the health status of microcirculation and as a component in the evaluation of cardiovascular risk factors. Typically, the evaluation is restricted to morphological appreciation without strict quantification. Our purpose was to develop and validate a software tool for semi-automated quantitative analysis of retinal vasculature in nonmydriatic fundus photography. Methods matlab software was used to develop a semi-automated image recognition and analysis tool for the determination of the arterial–venous (A/V) ratio in the central vessel equivalent on 45° digital fundus photographs. Validity and reproducibility of the r…
Acute extrahepatic infectious or inflammatory diseases are a cause of transient mosaic pattern on CT and MR imaging related to sinusoidal dilatation …
2015
To report the association of a mosaic enhancement pattern on contrast-enhanced CT or MR imaging and hepatic sinusoidal dilatation (SD) with acute inflammatory conditions affecting extrahepatic organs. From 2007 to 2012, patients with acute inflammatory diseases who underwent contrast-enhanced CT and/or MRI of the liver with a mosaic enhancement pattern were selected. Clinico-biological and other imaging features were collected at diagnosis and during follow-up. Sixteen patients were included (15 women, median age 27 years; range 18–68). Five women (33 %) were receiving oral contraceptives. Acute inflammatory diseases included pyelonephritis (n = 10), pancreatitis (n = 2), pneumonia (n = 1),…
Superficial thrombophlebitis in varicose vein disease: the particular role of methylenetetrahydrofolate reductase.
2010
Background The purpose of this study was to compare the genetic background of superficial (SVT) and deep vein thrombosis (DVT). Methods Factor V (FV)-Leiden (G16891A)-, factor II(G20210A)-mutations, protein C- and S, as well as methylenetetrahydrofolate reductase (MTHFR) polymorphisms at C677T and A1298C, and serum homocysteine levels (hcy) were determined in 29 patients with SVT and 26 with DVT. Findings FV- and –II-mutations were less frequent in patients with SVT (2/3) compared with DVT (9/5), respectively ( P < 0.002 in case of FV). However, the frequency of the MTHFR C677T polymorphism was significantly higher in patients with SVT compared with DVT (CT 12 versus 10, and TT 7 versus …
Heterogeneous delayed enhancement of hepatic parenchyma after intravenous infusion of sonographic contrast agent: a new hypothesis
2007
Purpose. The aim of this paper was to report a heterogeneous latephase hepatic enhancement pattern observed after administration of a sonographic contrast agent and to present an aetiological hypothesis for the phenomenon. Materials and methods. A total of 1,729 (1,012 women and 717 men; age range 28–82; mean age 51) patients underwent contrastenhanced sonography of the liver. The examination was performed with a low mechanical index (MI <0.09) after injection of sulphur-hexafluoride-filled microbubbles, using different fonographic equipment and different contrast-specific algorithms. Results. Heterogeneous delayed liver enhancement was observed in six patients in the late phase (180 s), wi…
Case report: acute portal vein thrombosis associated with acute cytomegalovirus infection in an immunocompetent adult
2017
Cytomegalovirus (CMV) infection is usually asymptomatic and self-limiting in healthy individuals, but significant complications can develop in immunosuppressed patients. Venous or arterial thromboembolic phenomena are uncommon yet very serious complications of CMV infection. Most published reports describe immunosuppressed patients, but thrombotic events in CMV-infected immunocompetent individuals may also occur. We describe the case of an immunocompetent young man with acute CMV hepatitis that was complicated with portal vein thrombosis (PVT). We also review the literature regarding the association between PVT and CMV in immunocompetent patients. Thromboembolism is an underestimated but si…