Search results for " ventilation"
showing 10 items of 372 documents
Acute respiratory distress syndrome in traumatic brain injury: how do we manage it?
2017
Abstract: Traumatic brain injury (TBI) is an important cause of morbidity and mortality worldwide. TBI patients frequently suffer from lung complications and acute respiratory distress syndrome (ARDS), which is associated with poor clinical outcomes. Moreover, the association between TBI and ARDS in trauma patients is well recognized. Mechanical ventilation of patients with a concomitance of acute brain injury and lung injury can present significant challenges. Frequently, guidelines recommending management strategies for patients with traumatic brain injuries come into conflict with what is now considered best ventilator practice. In this review, we will explore the strategies of the best …
Comparative bench study evaluation of different infant interfaces for non-invasive ventilation
2018
Abstract Background To compare, in terms of patient-ventilator interaction and performance, a new nasal mask (Respireo, AirLiquide, FR) with the Endotracheal tube (ET) and a commonly used nasal mask (FPM, Fisher and Paykel, NZ) for delivering Pressure Support Ventilation (PSV) in an infant model of Acute Respiratory Failure (ARF). Methods An active test lung (ASL 5000) connected to an infant mannequin through 3 different interfaces (Respireo, ET and FPM), was ventilated with a standard ICU ventilator set in PSV. The test lung was set to simulate a 5.5 kg infant with ARF, breathing at 50 and 60 breaths/min). Non-invasive ventilation (NIV) mode was not used and the leaks were nearly zero. Res…
Noninvasive oscillatory ventilation (NHFOV) in infants: Another brick in the wall of paediatric noninvasive ventilation?
2016
Reliability of automatic detection of AHI during positive airway pressure treatment in obstructive sleep apnea patients: A “real-life study”
2021
Introduction: Automatic event detection (AED) of residual apnea-hypopnea index (AHI) by ventilators is a current practice in sleep and mechanical ventilation Units but this methodology has not been validated in an unselected population of OSA patients. Aim of the present study was to assess in a “real-life” condition the reliability of AED during PAP therapy by the in-built software compared to full polysomnography during follow-up. Methods: We enrolled 300 OSA patients (105 F; AHI 45.3 ± 27.8) already on Positive airway pressure (PAP) therapy: 53% of the patients were on CPAP while other modalities were used in the rest of the sample. Results: Overall, the built-in software identified resi…
Influence of different interfaces on synchrony during pressure support ventilation in a pediatric setting: a bench study
2015
BACKGROUND: In adults and children, patient-ventilator synchrony is strongly dependent on both the ventilator settings and interface used in applying positive pressure to the airway. The aim of this bench study was to determine whether different interfaces and ventilator settings may influence patient-ventilator interaction in pediatric models of normal and mixed obstructive and restrictive respiratory conditions. METHODS: A test lung, connected to a pediatric mannequin using different interfaces (endotracheal tube [ETT], face mask, and helmet), was ventilated in pressure support ventilation mode testing 2 ventilator settings (pressurization time [Timepress]50%/cycling-off flow threshold [T…
Long-term volume-targeted pressure-controlled ventilation: sense or nonsense?
2017
The technology underlying the development of novel ventilatory modes for long-term noninvasive ventilation of patients with chronic hypercapnia is continuously evolving. Volume-targeted pressure-controlled ventilation is a hybrid ventilation mode designed to combine the advantages of conventional ventilation modes, while avoiding their drawbacks. However, manufacturers have created different names and have patented algorithms and set-up variables, which can result in confusion for physicians and respiratory therapists. In addition, clear evidence for the superiority of this novel mode has not yet been established. These factors have most likely hindered more widespread use of this mode in c…
Secretion Management Must Be Considered When Reporting Success or Failure of Noninvasive Ventilation
2003
Patient-Ventilator Asynchronies: Clinical Implications and Practical Solutions
2020
Mechanical ventilation is a supportive treatment commonly applied in critically ill patients. Whenever the patient is spontaneously breathing, the pressure applied to the respiratory system depends on the sum of the pressure generated by the respiratory muscles and the pressure generated by the ventilator. Patient-ventilator interaction is of utmost importance in spontaneously breathing patients, and thus the ventilator should be able to adapt to patient's changes in ventilatory demand and respiratory mechanics. Nevertheless, a lack of coordination between patient and ventilator due to a mismatch between neural and ventilator timing throughout the respiratory cycle may make weaning difficul…
Prevalence and risk factors for delirium in critically ill patients with COVID-19 (COVID-D): a multicentre cohort study
2021
Background: To date, 750 000 patients with COVID-19 worldwide have required mechanical ventilation and thus are at high risk of acute brain dysfunction (coma and delirium). We aimed to investigate the prevalence of delirium and coma, and risk factors for delirium in critically ill patients with COVID-19, to aid the development of strategies to mitigate delirium and associated sequelae. Methods: This multicentre cohort study included 69 adult intensive care units (ICUs), across 14 countries. We included all patients (aged ≥18 years) admitted to participating ICUs with severe acute respiratory syndrome coronavirus 2 infection before April 28, 2020. Patients who were moribund or had life-suppo…