Search results for " ventilation"

showing 10 items of 372 documents

Adaptive Lung Ventilation (ALV) Evaluierung eines neuen closed loop-gesteuerten Beatmungsalgorithmus bei Eingriffen in �berstreckter Seitenlage

1996

The lateral decubitus position is the standard position for nephrectomies. There is a lack of data about the effects of this extreme position upon respiratory mechanics and gas exchange. In 20 patients undergoing surgery in the nephrectomy position, we compared a new closed-loop-controlled ventilation algorithm, adaptive lung ventilation (ALV), which adapts the breathing pattern automatically, to the respiratory mechanics with conventionally controlled mandatory ventilation (CMV). The aims of our study were (1) to describe positioning effects on respiratory mechanics and gas exchange, (2) to compare ventilatory parameters selected by the ALV controller with traditional settings of CMV, and …

Artificial ventilationSupine positionRespiratory ratebusiness.industrymedicine.medical_treatmentGeneral MedicineRespiratory physiologymedicine.diseaseAnesthesiology and Pain MedicinemedicineBreathingRestrictive lung diseaseRespiratory systembusinessAlgorithmTidal volumeDer Anaesthesist
researchProduct

Baclofenintoxikation bei chronischer Hämodialyse und Nierentransplantation

2008

Fourteen days after renal transplantation, at first gave with good transplant function, a 36-year-old woman developed neurogenic dysfunction of bladder emptying. This was treated with baclofen, 5 mg three times daily by mouth. Between the 7th and 10th treatment day she progressively developed an organic psychotic syndrome and increasing respiratory paralysis after the onset of renal failure, associated with rejection of the transplanted kidney which required dialysis. Plasma concentration of baclofen was 565 ng/ml (therapeutic range 80-400 ng/ml). After discontinuing the drug and renewed haemodialysis the baclofen level rapidly fell and the symptoms receded. In a second case, a 57-year-old …

Artificial ventilationbusiness.industrymedicine.medical_treatmentMeningoencephalitisGeneral Medicinemedicine.diseaseRespiratory paralysisTransplantationchemistry.chemical_compoundBaclofenRespiratory failurechemistryAnesthesiamedicinebusinessDialysisKidney transplantationDMW - Deutsche Medizinische Wochenschrift
researchProduct

Effektivit�t pr�klinischer Notfallversorgung Fiktion oder Fakt?

1996

The current increase in the cost of health care must be considered as a severe threat to the prehospital emergency services system. Two examples have been selected--the patient with polytrauma and the patient in cardiac arrest--to demonstrate the dilemma between a need for objective data and the requirements of emergency patients. Study results obtained in trauma patients indicating that total prehospital time, including scene time, is correlated to patient outcome have led to the conclusion that at the scene treatment by emergency physicians may be dispensable. It has, however also been demonstrated that the time required for medical treatment at the scene is equivalent to 20% of the total…

Artificial ventilationmedicine.medical_specialtyEmergency managementbusiness.industryDefibrillationmedicine.medical_treatmentMEDLINEGeneral Medicinemedicine.diseasePolytraumaAnesthesiology and Pain MedicineVentricular fibrillationHealth caremedicineCardiopulmonary resuscitationIntensive care medicinebusinessDer Anaesthesist
researchProduct

Are urban water bodies really cooling?

2020

Abstract Small urban water bodies, like ponds or canals, are often assumed to cool their surroundings during hot periods, when water bodies remain cooler than air during daytime. However, during the night they may be warmer. Sufficient fetch is required for thermal effects to reach a height of 1–2 m, relevant for humans. In the ‘Really cooling water bodies in cities’ (REALCOOL) project thermal effects of typical Dutch urban water bodies were explored, using ENVI-met 4.1.3. This model version enables users to specify intensity of turbulent mixing and light absorption of the water, offering improved water temperature simulations. Local thermal effects near individual water bodies were assesse…

Atmospheric ScienceDaytimeWIMEK010504 meteorology & atmospheric sciencesLandschapsarchitectuur en Ruimtelijke PlanningGeography Planning and DevelopmentFetchEquivalent temperatureNatural ventilation010501 environmental sciencesEnvironmental Science (miscellaneous)Atmospheric sciences01 natural sciencesUrban StudiesClimate ResilienceKlimaatbestendigheidThermalLandscape Architecture and Spatial PlanningWater coolingLife ScienceEnvironmental scienceUrban heat islandIntensity (heat transfer)0105 earth and related environmental sciencesUrban Climate
researchProduct

Optimisation of Heat Loss through Ventilation for Residential Buildings

2018

This study presents the results of research on heat loss from various types of residential buildings through ventilation systems. Experimental research was done to analyse the effectiveness of ventilation systems of different types and determine the parameters of air discharged via the ventilation ducts. A model of heat loss from the discharge of exhaust air outside through air ducts has since been developed. Experiments were conducted on three experimental systems of building ventilation: gravitational, mechanical, and supply-exhaust ventilation systems with heat recovery. The proposed model dependencies were used to chart the daily fluctuations of the optimum multiplicity of air exchange …

Atmospheric Scienceresidential buildingoptimisation020209 energymedicine.medical_treatmentAirflow02 engineering and technologylcsh:QC851-999Environmental Science (miscellaneous)law.inventioncarbon dioxide concentrationheat lossChartlawHeat recovery ventilation0202 electrical engineering electronic engineering information engineeringmedicineAir quality indexheat loss; optimisation; residential building; air quality; carbon dioxide concentration; ventilation systemMechanical ventilationHeat lossesNatural ventilationair qualityventilation systemVentilation (architecture)Environmental sciencelcsh:Meteorology. ClimatologyMarine engineeringAtmosphere
researchProduct

Obesity and Outcomes in COVID-19: When an Epidemic and Pandemic Collide.

2020

Obesity has reached epidemic proportions in the United States and in much of the westernized world, contributing to considerable morbidity. Several of these obesity-related morbidities are associated with greater risk for death with coronavirus disease 2019 (COVID-19). Severe acute respiratory syndrome coronavirus 2 penetrates human cells through direct binding with angiotensin-converting enzyme 2 receptors on the cell surface. Angiotensin-converting enzyme 2 expression in adipose tissue is higher than that in lung tissue, which means that adipose tissue may be vulnerable to COVID-19 infection. Obese patients also have worse outcomes with COVID-19 infection, including respiratory failure, n…

BMI body mass indexmedicine.medical_treatmentAdipose tissue030204 cardiovascular system & hematologyCHD coronary heart diseaseHF heart failureUS United States0302 clinical medicineRAAS renin-angiotensin-aldosterone systemPandemicMedicine030212 general & internal medicineCDC Centers for Disease Control and PreventionCOVID-19 coronavirus disease 2019TNF tumor necrosis factorHFpEF HF with preserved ejection fractionCV cardiovascularGeneral MedicinePrognosisICU intensive care unitPA physical activityMetS metabolic syndromePAH pulmonary arterial hypertensionCoronavirus Infectionsmedicine.medical_specialtyAF atrial fibrillationACE angiotensin-converting enzymePneumonia ViralCVD cardiovascular diseaseSARS-CoV-2 severe acute respiratory syndrome coronavirus 2ArticleSeverity03 medical and health sciencesBetacoronavirusInternal medicineIPF idiopathic pulmonary fibrosisHumansObesityMortalityHTN hypertension or hypertensivePandemicsMechanical ventilationAng II angiotensin IIbusiness.industrySARS-CoV-2CKD chronic kidney diseaseCOVID-19T2DM type 2 diabetes mellitusmedicine.diseaseAngiotensin IIObesityIL interleukinPneumoniaRespiratory failureMetabolic syndromebusinessSNS sympathetic nervousMayo Clinic proceedings
researchProduct

Investigating energy saving potential in a big shopping center through ventilation control

2019

Abstract This paper investigates energy saving measures for the ventilation system of large shopping centers. This kind of buildings is characterized by high yearly energy consumptions, because of the high level of operating hours and the frequent use of obsolete technologies. In the analyzed case studies, three big Do It Yourself (DIY) shops, located in Italy, are considered. Two different approaches are considered, they are aimed at reducing the annual energy consumption for the indoor air exchange of the sales area. The first considered retrofit solution consists in the installation of heat recovery exchangers, reducing the energy demand for the air thermal treatment without changing the…

Buildings Energy savingGeography Planning and DevelopmentAirflow0211 other engineering and technologiesTransportation02 engineering and technology010501 environmental sciences01 natural sciencesAutomotive engineeringlaw.inventionVentilation controlIndoor air qualitylawHeat recovery ventilationVentilation control021108 energyShopping centerIndoor air qualityAir quality index0105 earth and related environmental sciencesCivil and Structural EngineeringSettore ING-IND/11 - Fisica Tecnica AmbientaleRenewable Energy Sustainability and the EnvironmentEnergy consumptionSettore ING-IND/33 - Sistemi Elettrici Per L'EnergiaVentilation (architecture)Environmental scienceEnergy (signal processing)
researchProduct

Investigating Energy Saving Potential in a Big Shopping Centre through Ventilation Control

2018

This work shows an example of energy saving interventions on the ventilation system of a big shopping center. This kind of buildings is characterized by high energy consumptions, because of the high level of yearly operating hours and the use of obsolete technologies. In the case study, a big Do It Yourself (DIY) shop located in the southern part of Italy is analyzed, proposing two different approaches aimed at reducing the annual energy consumption for the indoor air exchange of the sales area. In the AS-IS scenario, a centralized HVAC plant, composed by six rooftops, is installed on the roof of sales area, working with fixed airflow value. The first retrofit solution involves the installa…

Buildings Energy saving Indoor Air Quality Shopping Center Ventilation Control
researchProduct

Skin conductance measurement for the assessment of analgosedation adequacy in infants treated with mechanical ventilation: A multicenter pilot study

2020

Background Patients treated in neonatal/pediatric intensive care units (N/PICUs) are frequently exposed to pain. To assess its severity, several behavioral and behavioral-physiological scales are used, but their usefulness is limited. It is therefore justified to search for additional methods to assess the adequacy of analgesia and sedation in these patients. Objectives To evaluate the usefulness of skin conductance (SC) measurement in the assessment of analgosedation quality in infants requiring mechanical ventilation treated in N/PICUs. Material and methods Thirty infants aged 6-208 days treated in 6 N/PICUs, mechanically ventilated and receiving analgosedation, were included for the stud…

COMFORT-B scaleSedationmedicine.medical_treatmentMedicine (miscellaneous)Pilot ProjectsIntensive Care Units PediatricGeneral Biochemistry Genetics and Molecular Biologyskin conductanceIntensive careInternal MedicinemedicineHumansPharmacology (medical)painChildGenetics (clinical)Mechanical ventilationAlgesimeterbusiness.industryInfant NewbornRespiration ArtificialinfantClinical PracticeAnesthesiaReviews and References (medical)analgosedationmedicine.symptomAnalgesiabusinessSkin conductanceAdvances in Clinical and Experimental Medicine
researchProduct

Sedation and analgesia during noninvasive ventilation (NIV)

2017

The use of noninvasive ventilation (NIV) has increased significantly in patients with acute respiratory failure (ARF) in order to prevent tracheal intubation and its complications. Unfortunately, NIV failure represents a frequent event, with rates that in some cases reach 40%. Mask intolerance, agitation, and delirium may lead to NIV failure, thus requiring endotracheal intubation. NIV failure rates are higher in patients without chronic obstructive pulmonary disease (COPD), and, when used in acute hypoxemic failure, its failure is associated with an increased mortality rate. The practice of sedation during NIV could be a valuable option for patients at risk of intubation. Sedation may decr…

COPDbusiness.industrySedationmedicine.medical_treatmentMortality rateventilationTracheal intubation030208 emergency & critical care medicineEndotracheal intubationmedicine.disease03 medical and health sciences0302 clinical medicine030228 respiratory systemsedationAnesthesiamedicineDeliriumNoninvasive ventilationmedicine.symptomDexmedetomidinebusinessmedicine.drug
researchProduct