Search results for " vessels"

showing 10 items of 303 documents

Microvascular obstruction in non-STEMI related areas: An uninvited guest in STEMI?

2018

medicine.medical_specialtybusiness.industryMyocardial Infarction030204 cardiovascular system & hematologyCoronary Vessels03 medical and health sciences0302 clinical medicinePercutaneous Coronary InterventionNon stemiInternal medicinemedicineCardiologyHumansST Elevation Myocardial Infarction030212 general & internal medicineCardiology and Cardiovascular MedicinebusinessInternational journal of cardiology
researchProduct

Duplexsonographie abdomineller Gefäße

1987

Duplex sonography is a non-invasive procedure which permits the determination of flow velocity and direction in visceral vessels. Results in 50 normals have shown that small arteries can be evaluated in about 50% of cases. The portal venous system can be demonstrated in all cases; average flow velocity and volume is 15.2 +/- 2.8 cm/s and 694 +/- 230 ml/min, corresponding with the values obtained by invasive methods. Clinical application for duplex examinations can be found in portal hypertension, varices, thromboses, aneurysms and transplant kidneys.

medicine.medical_specialtybusiness.industryPortal venous systemfood and beveragesmedicine.diseaseSurgerymedicine.anatomical_structureFlow velocityDuplex (building)Duplex sonographyMedicineAbdomenPortal hypertensionRadiology Nuclear Medicine and imagingVaricesNuclear medicinebusinessAbdominal vesselsRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Bifocal Stimulation in Patient with Congenitally Corrected Transposition of Great Vessels

2011

Congenitally corrected transposition of the great vessels (CCTGV) is a rare congenital heart defect associated with multiple cardiac morphological abnormalities and conduction defects. Complete atrioventricular (AV) block occurs in 30% of patients and it may be present at birth or develop later with a rate of 2% per year; moreover, a systemic right ventricle is frequently characterized by heart failure in adult life. We used a bifocal cardiac stimulation for a young woman affected by CCTGV and atrioventricular Mobitz 2 and 2:1 block, considering structural, anatomic condition, and the high rate of pacing she underwent. (PACE 2012; 35:e296–e298)

medicine.medical_specialtybusiness.industryStimulationGeneral Medicinemedicine.diseaseSurgeryAdult lifemedicine.anatomical_structureCongenitally corrected transpositionGreat vesselsVentricleHeart failureInternal medicinecardiovascular systemmedicineCardiologyIn patientCardiology and Cardiovascular MedicinebusinessCardiac stimulationPacing and Clinical Electrophysiology
researchProduct

Gradual angioplasty and stent implantation to treat complete superior vena cava occlusion after Mustard procedure

1996

A 16-year-old male was admitted with complete occlusion of the superior vena cava pathway 14 years after Mustard procedure for transposition of the great arteries. From a left subclavian vein approach, the atretic vein segment was perforated using a straight guidewire, and was followed by sequential balloon dilation. Implantation of a 30 mm Palmaz-stent through a femoral vein approach resulted in a widely patent channel of the vena cava superior into the systemic venous atrium. © 1996 Wiley-Liss, Inc.

medicine.medical_specialtybusiness.industrymedicine.medical_treatmentFemoral veinTransposition of the great vesselsmedicine.diseaseSurgerySuperior Vena Cava Occlusionmedicine.anatomical_structureSuperior vena cavaAngioplastycardiovascular systemBalloon dilationmedicinecardiovascular diseasesRadiologyAtrium (heart)Cardiology and Cardiovascular MedicinebusinessMustard procedureCatheterization and Cardiovascular Diagnosis
researchProduct

Congenitally corrected transposition of great vessels: MRI and echocardiographic appearance

1995

This paper presents the case of a 36-year-old male with congenitally corrected transposition of great vessels (CTGV). This is a rare cardiac anomaly characterized by atrioventricular and ventriculoarterial discordance, occuriing in less than 1% of all congenital heart diseases. This was diagnosed by echocardiography and MRI. The MRI findings demonstrated cardiac abnormality.

medicine.medical_specialtymedicine.diagnostic_testbusiness.industryHeart malformationUltrasoundInterventional radiologyGeneral MedicineCongenitally corrected transpositionGreat vesselsInternal medicinecardiovascular systemmedicineCardiologyCARDIAC ANOMALYRadiology Nuclear Medicine and imagingRadiologybusinessMri findingsNeuroradiologyEuropean Radiology
researchProduct

Modelling the effect of porosity on the mechanical properties of unidirectional composites. The case of thick-walled pressure vessels

2018

International audience; The present article highlights morphological features present in composite pressure vessels. The use of X-ray microtomography provides three-dimensional information about the voids in a large thick-walled type 3 pressure vessel at the mesoscopic scale. The observations show that the porosity structure depends strongly on composite thickness and orientation. A numerical approach is proposed to model realistically the damage phenomena in pressure vessels.

microtomographyporositypressure vesselsfilament winding[SPI.MECA.MEMA]Engineering Sciences [physics]/Mechanics [physics.med-ph]/Mechanics of materials [physics.class-ph][SPI.MAT] Engineering Sciences [physics]/Materials[SPI.MECA.MEMA] Engineering Sciences [physics]/Mechanics [physics.med-ph]/Mechanics of materials [physics.class-ph][SPI.MAT]Engineering Sciences [physics]/Materials
researchProduct

Drug-Coated Balloon vs. Stent for de novo Non-small Coronary Artery Disease: A Systematic Review and Meta-Analysis

2021

Introduction: Drug-coated balloon (DCB) has been an attractive option in de novo vessels. A systematic review and meta-analysis were conducted to evaluate the efficacy and safety of DCB vs. stent for treating de novo lesions in non-small vessels.Methods: Studies in PubMed, Embase, the Cochrane Central Register of Controlled Trials, and Web of Science were searched (from their commencement to March 2021). This meta-analysis was performed by Review Manager 5.3.Results: A total of 3 random controlled trials (RCTs) with 255 patients and 2 observational studies (OS) with 265 patients were included in this meta-analysis following our inclusion criteria. It could be observed that DCB presented no …

non-smallsystematic reviewRC666-701drug-coated balloonDiseases of the circulatory (Cardiovascular) systemde novo vesselsstentCardiovascular MedicineCardiology and Cardiovascular MedicineFrontiers in Cardiovascular Medicine
researchProduct

Proof testing and lifetime reliability of carbon fibre reinforced composite pressure vessels

2013

International audience

reliability[ SPI.MAT ] Engineering Sciences [physics]/Materialsfailure processescarbon fibre pressure vessels[SPI.MAT] Engineering Sciences [physics]/Materials[SPI.MECA]Engineering Sciences [physics]/Mechanics [physics.med-ph][SPI.MECA] Engineering Sciences [physics]/Mechanics [physics.med-ph]ComputingMilieux_MISCELLANEOUS[SPI.MAT]Engineering Sciences [physics]/Materials
researchProduct

A methodology for the control of the residual lifetimes of carbon fibre reinforced composite pressure vessels

2005

International audience; Pressure vessels must be periodically proof tested. Traditional techniques for metal vessels are inapplicable for composite vessels as the latter do not break by crack propagation so that the reasoning behind the traditional testing procedures is not appropriate. Damage accumulation leading to the degradation of a composite vessel is by fibre failure. Fibres show a wide distribution in strengths and loading a composite inevitably breaks some. The method which has been developed is supported by an analysis of delayed fibre failure due to the relaxation of the resin around fibre breaks. This provokes overloading of intact fibres neighbouring breaks. The time until a cr…

resin relaxationlife time predictionpressure vesselsproof testingdelayed fibre failurecarbon fibre composites[PHYS.COND.CM-MS]Physics [physics]/Condensed Matter [cond-mat]/Materials Science [cond-mat.mtrl-sci]resin relaxation.[ PHYS.COND.CM-MS ] Physics [physics]/Condensed Matter [cond-mat]/Materials Science [cond-mat.mtrl-sci]acoustic emission[PHYS.COND.CM-MS] Physics [physics]/Condensed Matter [cond-mat]/Materials Science [cond-mat.mtrl-sci]
researchProduct

Effect of mesoangioblast extracellular vesicle on cell migration and vessel formation of human endothelial cell

2015

stem cells mesoangioblast membrane vesicles migration endothelial cells vessels
researchProduct