Search results for " vol"

showing 10 items of 3179 documents

Redundant and synergistic information transfer in cardiovascular and cardiorespiratory variability

2015

In the framework of information dynamics, new tools are emerging which allow one to quantify how the information provided by two source processes about a target process results from the contribution of each source and from the interaction between the sources. We present the first implementation of these tools in the assessment of short-term cardiovascular and cardiorespiratory variability, by introducing two strategies for the decomposition of the information transferred to heart period (HP) variability from systolic arterial pressure (SAP) and respiration flow (RF) variability. Several measures based on the notion of transfer entropy (TE) are defined to quantify joint, individual and redun…

AdultMaleInformation transferComputer scienceEntropyBiomedical EngineeringBlood PressureHealth Informaticscomputer.software_genreCardiovascular Physiological PhenomenaElectrocardiographyHeart RateHumansPaced breathingSimulation1707Motor NeuronsRespirationModels CardiovascularHealthy subjectsHeartCardiorespiratory fitnessHealthy VolunteersSignal ProcessingSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaSystolic arterial pressureFemaleTransfer entropyData miningcomputer
researchProduct

Respiratory Mechanics, Gastric Insufflation Pressure, and Air Leakage of the Laryngeal Mask Airway

1997

A potential risk of the laryngeal mask airway (LMA) is incomplete mask seal, which causes air leakage or insufflation of air into the stomach. The objective of the present study was to assess respiratory mechanics, quantify air leakage, and measure gastric air insufflation in patients ventilated via the LMA. Thirty patients were studied after induction of anesthesia but prior to any surgical manipulations. After the insertion of the LMA, patients were ventilated with increasing tidal volumes until one of the three following end points were reached: 1) gastric air insufflation, 2) airway pressure > 40 cm H2O, or 3) limitation of further increase in tidal volume by air leakage. The following …

AdultMaleInsufflationLeakAdolescentRespiratory physiologyLaryngeal MasksLaryngeal mask airwayPressureTidal VolumemedicineHumansRespiratory systemTidal volumebusiness.industryStomachStomachInsufflationMiddle Agedrespiratory systemRespiration Artificialmedicine.anatomical_structureAnesthesiology and Pain MedicineAnesthesiaRespiratory MechanicsFemalebusinessAirwayAnesthesia & Analgesia
researchProduct

Transpalpebral tonometry: reliability and comparison with Goldmann applanation tonometry and palpation in healthy volunteers

2005

Background/aim: TGDc-01 is a new, portable, transpalpebral tonometry device. The aim of this study was to evaluate the reproducibility of this method, including intraobserver and interobserver deviations, and to compare the results with those of Goldmann applanation tonometry and palpation of intraocular pressure (IOP). Methods: A total of 40 eyes of 20 healthy volunteers were included. Two independent parallel observers (1 and 2) performed three replicate measurements per eye, respectively, both using TGDc01 tonometry, one observer (3) performed three replicate measurements using Goldmann applanation tonometry, and one observer (4) measured the IOP via palpation. Intraindividual deviations…

AdultMaleIntraocular pressuremedicine.medical_specialtyClinical Science - Scientific ReportsPalpationGoldmann applanation tonometryTonometry OcularCellular and Molecular NeuroscienceInterquartile rangeOphthalmologyHealthy volunteersHumansMedicineIn patientIntraocular PressureObserver VariationReproducibilityPalpationmedicine.diagnostic_testbusiness.industryReproducibility of ResultsEquipment DesignSensory SystemsOphthalmologyQuartileFemalebusinessBritish Journal of Ophthalmology
researchProduct

Volumetry of Ventilated Airspaces by 3He MRI

2001

To develop a validated post-processing routine for volumetry of the ventilated airspaces by 3He MRI.3Helium MRI and pulmonary function tests were performed in seven healthy volunteers. After segmentation of ventilated airspaces, their volumes were calculated. Functional residual capacity (FRC) was used as a reference. For comparison of absolute volumes, correction factors were evaluated.Mean lung volume (+/- standard deviation) calculated from 3He MRI was 4,082 +/- 908 mL and mean FRC was 3,696 +/- 1166 mL, with a mean difference of 386 mL (r = 0.88). After correction for the relative pulmonary air content (factor 0.82), posture (0.72), and the individual tidal volume, 3He MRI volume was 3,…

AdultMaleIsotopesImage Processing Computer-AssistedHumansFemaleRadiology Nuclear Medicine and imagingGeneral MedicineLung Volume MeasurementsHeliumMagnetic Resonance ImagingInvestigative Radiology
researchProduct

Tidal Volume Estimation during Helmet Noninvasive Ventilation: an Experimental Feasibility Study

2019

AbstractWe performed a bench (BS) and human (HS) study to test the hypothesis that estimation of tidal volume (VT) during noninvasive helmet pressure support ventilation (nHPSV) would be possible using a turbine driven ventilator (TDV) coupled with an intentional leak single-limb vented circuit. During the BS a mannequin was connected to a lung simulator (LS) and at different conditions of respiratory mechanics, positive end expiratory pressure (PEEP) levels and leaks (30, 50 and 80 L/min). All differences were within the 95% limits of agreement (LoA) in all conditions in the Bland-Altman plot. The overall bias (difference between VT measured by TDV and LS) was 35 ml (95% LoA 10 to 57 ml), …

AdultMaleLeakmedicine.medical_specialtylcsh:MedicineSettore MED/41 - AnestesiologiaPressure support ventilationTherapeuticsRespiratory physiologyManikinsArticlePositive-Pressure Respiration03 medical and health sciences0302 clinical medicineInternal medicineHealthy volunteersTidal VolumemedicineHumanslcsh:SciencePositive end-expiratory pressureTidal volumeMouthpieceVentilators Mechanicalacute respiratory failureMultidisciplinarybusiness.industrylcsh:RhelmetReproducibility of Resultsnoninvasive ventilation030208 emergency & critical care medicineEquipment DesignHealthy Volunteers030228 respiratory systemPreclinical researchRespiratory MechanicsCardiologyFeasibility Studieslcsh:QFemaleHead Protective DevicesNoninvasive ventilationbusinessScientific Reports
researchProduct

Light distortion of soft multifocal contact lenses with different pupil size and shape

2020

Purpose: To study the light distortion effects of soft multifocal contact lenses and the influence of different pupil size and shape.Methods: A total of 14 eyes of 7 healthy contact lens users (mean age 28.6 +/- 8.5 years) were recruited. The "Light Disturbance Analyser" device was employed for light characterization. The selected lenses were the monthly disposable "Biofinity multifocal" (CooperVision, CA, USA), both centre-distance and centre-near designs (addition power + 2.50 D). Two circular pupils of 3 mm and 5 mm of diameter, and an elliptical shape (3 horizontal and 5 vertical mm) were used. Metrics such as the light distortion index (LDI), best-fit circle radius and its irregularity…

AdultMaleLight distortionbusiness.product_categorygenetic structuresCiências Naturais::Ciências Físicas:Ciências Físicas [Ciências Naturais]Visual AcuityRefraction OcularPupillaw.invention03 medical and health sciences0302 clinical medicineOpticslawDistortionNon-circular pupilsHumansMultifocal lensesMathematicsScience & Technologybusiness.industryPupil sizePupilMean ageEquipment DesignGeneral MedicineRadiusMiddle AgedContact Lenses HydrophilicRefractive ErrorsHealthy Volunteerseye diseasesContact lensLens (optics)Ophthalmology030221 ophthalmology & optometryMultifocal contact lensesFemalesense organsbusiness030217 neurology & neurosurgeryOptometryContact Lens and Anterior Eye
researchProduct

Beyond the amygdala: Linguistic threat modulates peri-sylvian semantic access cortices

2015

In this study, healthy volunteers were scanned using functional magnetic resonance imaging (fMRI) to investigate the neural systems involved in processing the threatening content conveyed via visually presented “threat words.” The neural responses elicited by these words were compared to those elicited by matched neutral control words. The results demonstrate that linguistic threat, when presented in written form, can selectively engage areas of lateral temporal and inferior frontal cortex, distinct from the core language areas implicated in aphasia. Additionally, linguistic threat modulates neural activity in visceral/emotional systems (amygdala, parahippocampal gyrus and periaqueductal gr…

AdultMaleLinguistics and LanguageVisual perceptionAdolescentCognitive NeuroscienceNeocortexExperimental and Cognitive PsychologyAmygdalaBrain mappingArticleLanguage and LinguisticsYoung AdultSpeech and HearingFunctional neuroimagingAphasiaAphasiamedicineHumansPeriaqueductal GrayBrain MappingLanguage Testsmedicine.diagnostic_testFearAmygdalaMagnetic Resonance ImagingHealthy VolunteersLinguisticsFrontal LobeSemanticsmedicine.anatomical_structureFrontal lobeVisual PerceptionParahippocampal GyrusFemalemedicine.symptomPsychologyFunctional magnetic resonance imagingParahippocampal gyrusCognitive psychologyBrain and Language
researchProduct

“Anatomical” versus “Territorial” Belonging of the Middle Hepatic Vein: Virtual Imaging and Clinical Repercussions

2011

Background Venous drainage patterns are of vital importance in live donor liver transplantation. The purpose of this study was to delineate “anatomical-topographical” and “territorial-physiologic” patterns of the middle hepatic vein (MHV) in a 3-D liver model as determined by the Pringle line and its drainage volume of the right and left hemilivers. Methods One hundred thirty-seven consecutive live donor candidates were evaluated by 3-D CT reconstructions and virtual hepatectomies. Based on right (R) and left (L), anatomical (A) and territorial (T) belonging patterns of the MHV, each individual was assigned to one of four possible types: type I:AR–TR; type II:AL–TL; type III:AR–TL; type IV:…

AdultMaleLive donormedicine.medical_treatmentMedizinLiver transplantationHepatic VeinsDrainage volumeImaging Three-DimensionalVenous congestionmedicineLiving DonorsHepatectomyHumansVirtual imagingbusiness.industryVenous drainageAnatomyPhlebographyAnatomy RegionalMiddle AgedLiver TransplantationLiverRight hemiliverSurgeryFemaleLiving donor liver transplantationbusinessTomography X-Ray ComputedLiver Circulation
researchProduct

An Emerging Method to Assess Tear Film Spread and Dynamics as Possible Tear Film Homeostasis Markers

2021

This study aims to assess the performance of an analysis method to measure in vivo the movement speed of tear film particles post-blink as a measure of tear film spreading. Ocular surface parameter...

AdultMaleMaterials scienceAdolescentgenetic structuresMeasure (physics)Young Adult03 medical and health sciencesCellular and Molecular Neuroscience0302 clinical medicineHomeostasisHumansAnalysis methodAgedAged 80 and overBlinkingDynamics (mechanics)Meibomian GlandsMiddle AgedHealthy Volunteerseye diseasesSensory SystemsOphthalmologyTears030221 ophthalmology & optometryDry Eye SyndromesFemalesense organsOcular surface030217 neurology & neurosurgeryBiomedical engineeringCurrent Eye Research
researchProduct

Transthoracic three-dimensional echocardiographic volumetry of distorted left ventricles using rotational scanning

1997

The purpose of this study was to evaluate the relation of transthoracic three- and two-dimensional echocardiographic left ventricular volumetry to cineventriculographic volumetry. Twenty-five patients with distorted left ventricles were included in the study. To demonstrate the impact of acquiring data by rotational scanning, we performed three- and two-dimensional echocardiography in 36 latex ventricles with data acquisition in different areas of the ultrasound sectors. Interobserver and intraobserver variability were calculated to test for reproducibility. The three-dimensional imaging system consisted of a rotation motor device, a transthoracic 2.5 MHz transducer, a conventional ultrasou…

AdultMaleModels Anatomicmedicine.medical_specialtyCardiac VolumeHeart VentriclesCardiac VolumeLeft VentriclesConventional ultrasoundRoot mean squareImage Processing Computer-AssistedHumansMedicineRadiology Nuclear Medicine and imagingAgedObserver VariationReproducibilitybusiness.industryUltrasoundReproducibility of ResultsMiddle AgedTransducermedicine.anatomical_structureVentricleRegression AnalysisFemaleRadiologyCardiology and Cardiovascular MedicinebusinessEchocardiography TransesophagealJournal of the American Society of Echocardiography
researchProduct