Search results for "010309 optics"
showing 10 items of 1175 documents
Role of topological phase-defects in the parametric generation process
2008
Abstract We show that topological phase-defects are spontaneously generated from noise fluctuations in the degenerate configuration of the parametric interaction. These localized coherent structures are shown to affect the coherence properties of the parametrically generated field. It is shown that the emergence of coherence in the fundamental field relies on a previously unrecognized process of mutual annihilation of pairs of neighboring phase-defects. More precisely, the density of phase-defects N , and the time correlation τ c of the generated field, are shown to exhibit a power-law behavior with the propagation length, i.e., τ c ∝ z 1 / 4 , N ∝ z - 1 / 4 .
Disorder-induced single-mode transmission.
2017
Localized states trap waves propagating in a disordered potential and play a crucial role in Anderson localization, which is the absence of diffusion due to disorder. Some localized states are barely coupled with neighbours because of differences in wavelength or small spatial overlap, thus preventing energy leakage to the surroundings. This is the same degree of isolation found in the homogeneous core of a single-mode optical fibre. Here we show that localized states of a disordered optical fibre are single mode: the transmission channels possess a high degree of resilience to perturbation and invariance with respect to the launch conditions. Our experimental approach allows identification…
2D Waveguided Bessel Beam Generated Using Integrated Metasurface-Based Plasmonic Axicon.
2020
International audience; Near-field imaging of the propagation of a diffraction-free Bessel-type beam in a guided wave configuration generated by means of a metasurface-based axicon lens integrated on a silicon waveguide is reported. The operation of the axicon lens with a footprint as small as 11 μm2 is based on local engineering of the effective index of the silicon waveguide with plasmonic nanoresonators. This generic approach, which can be adapted to different types of planar lightwave circuit platforms, offers the possibility to design nano-engineered optical devicesbased on the use of plasmonic resonators to control light at the nanoscale.
ORIGIN: metal creation and evolution from the cosmic dawn
2012
Herder, Jan-Willem den et al.
Remote Photoplethysmography measurement using constrained ICA
2017
Remote Photoplethysmography (rPPG) is a technique that consists in estimating physiological parameters such as heart rate from live or recorded video sequences taken by conventional camera or even webcams. This technique is increasingly used in many application fields thanks to its simplicity and affordability. The basic idea is that the arterial blood flow shows regularity due to the heartbeat. This regularity is manifested by very small periodic variations in the color of the skin, which can be isolated and quantified by signal and image processing methods. In this context, Independent Component Analysis (ICA) is largely used to separate the signal due to arterial flow from signals from o…
Homodyne Solid-State Biased Coherent Detection of Ultra-Broadband Terahertz Pulses with Static Electric Fields.
2021
We present an innovative implementation of the solid-state-biased coherent detection (SSBCD) technique, which we have recently introduced for the reconstruction of both amplitude and phase of ultra-broadband terahertz pulses. In our previous works, the SSBCD method has been operated via a heterodyne scheme, which involves demanding square-wave voltage amplifiers, phase-locked to the THz pulse train, as well as an electronic circuit for the demodulation of the readout signal. Here, we demonstrate that the SSBCD technique can be operated via a very simple homodyne scheme, exploiting plain static bias voltages. We show that the homodyne SSBCD signal turns into a bipolar transient when the stat…
Apertureless scanning near-field optical microscopy: a comparison between homodyne and heterodyne approaches
2006
International audience; In coherent homodyne apertureless scanning near-field optical microscopy (ASNOM) the background field cannot be fully suppressed because of the interference between the different collected fields, making the images difficult to interpret. We show that implementing the heterodyne version of ASNOM allows one to overcome this issue. We present a comparison between homodyne and heterodyne ASNOM through near-field analysis of gold nanowells, integrated waveguides, and a single evanescent wave generated by total internal reflection. The heterodyne approach allows for the control of the interferometric effect with the background light. In particular, the undesirable backgro…
Roadmap on digital holography [Invited]
2021
This Roadmap article on digital holography provides an overview of a vast array of research activities in the field of digital holography. The paper consists of a series of 25 sections from the prominent experts in digital holography presenting various aspects of the field on sensing, 3D imaging and displays, virtual and augmented reality, microscopy, cell identification, tomography, label-free live cell imaging, and other applications. Each section represents the vision of its author to describe the significant progress, potential impact, important developments, and challenging issues in the field of digital holography.
Single-exposure super-resolved interferometric microscopy by RGB multiplexing in lensless configuration
2016
Abstract Single-Exposure Super-Resolved Interferometric Microscopy (SESRIM) reports on a way to achieve one-dimensional (1-D) superresolved imaging in digital holographic microscopy (DHM) by a single illumination shot and digital recording. SESRIM provides color-coded angular multiplexing of the accessible sample׳s range of spatial frequencies and it allows their recording in a single CCD (color or monochrome) snapshot by adding 3 RGB coherent reference beams at the output plane. In this manuscript, we extend the applicability of SESRIM to the field of digital in-line holographic microscopy (DIHM), that is, working without lenses. As consequence of the in-line configuration, an additional r…
The Wide Field Imager instrument for Athena
2017
ESA's next large X-ray mission ATHENA is designed to address the Cosmic Vision science theme 'The Hot and Energetic Universe'. It will provide answers to the two key astrophysical questions how does ordinary matter assemble into the large-scale structures we see today and how do black holes grow and shape the Universe. The ATHENA spacecraft will be equipped with two focal plane cameras, a Wide Field Imager (WFI) and an X-ray Integral Field Unit (X-IFU). The WFI instrument is optimized for state-of-The-Art resolution spectroscopy over a large field of view of 40 amin x 40 amin and high count rates up to and beyond 1 Crab source intensity. The cryogenic X-IFU camera is designed for high-spect…