Search results for "030218 nuclear medicine & medical imaging"
showing 10 items of 1054 documents
Efficacy and one-year outcomes of Luminor® paclitaxel-coated drug-eluting balloon in the treatment of popliteal artery atherosclerosis lesions
2021
Purpose: Reporting outcomes with a new generation paclitaxel eluting balloon (Luminor®; iVascular, Vascular, S.L.U., Barcelona, Spain) in the popliteal district. Endovascular treatment of popliteal artery atherosclerotic disease is still debated without definitive evidences. Methods: From January to June 2019, patients’ data presenting popliteal artery atherosclerotic diseases and treated with the Luminor® (iVascular) drug eluting balloon (DEB) were prospectively collected. Critical limb ischemia (CLI) or severe claudication associated with popliteal artery stenosis >50% were the inclusion criteria. Measured outcomes were technical success, early and late results; including mortality, mo…
The effect of chronic low-dose environmental radiation on organ mass of bank voles in the Chernobyl Exclusion Zone
2020
Purpose: Animals are exposed to environmental ionizing radiation (IR) externally through proximity to contaminated soil and internally through ingestion and inhalation of radionuclides. Internal organs can respond to radioactive contamination through physiological stress. Chronic stress can compromise the size of physiologically active organs, but studies on wild mammal populations are scarce. The effects of environmental IR contamination on organ masses was studied by using a wild rodent inhabiting the Chernobyl Exclusion Zone (CEZ). Material and Methods: The masses of brain, heart, kidney, spleen, liver and lung were assessed from bank voles (Myodes glareolus) captured from areas across r…
Modulation of Exposure to Static Magnetic Field Affects Targeted Therapy of Solid Tumors In Vivo
2018
Background Static magnetic fields (SMF) exhibit antitumoral activity and enhance the efficacy of chemotherapy by opening the tumor-blood barrier. This study aimed to analyze different SMF-exposure protocols on epidermal growth factor receptor (EGFR)-overexpressing tumors, as well as their combination with cetuximab. Materials and methods Experiments were performed in skinfold chamber preparations of C57Bl/6-and CD-1nu/nu mice bearing LLC-1 tumors. Animals were exposed to 587 mT magnetic field following different exposure protocols. A subgroup received additional cetuximab injections. Using in vivo-fluorescence microscopy and planimetry, tumor angiogenesis, growth and microcirculation were r…
CT-guided nephrostomy–An expedient tool for complex clinical scenarios
2018
Abstract Introduction & objectives Percutaneous nephrostomy [ 1 ] has emerged as a pivotal approach in the therapeutic management of the obstructed urinary tract. A consecutive incorporation of ultrasonic and radiographic guidance, the approach experienced an almost ubiquitious distribution while most centers currently applying either one or both of these tools jointly. However, success of ultrasound-guidance is limited in obese patients and non-dilated uropathy. In turn, fluoroscopy usually requires an opacification of the urinary collecting system by intravenous or antegrade contrast media injection, which might be harmful for already impaired renal function, raise intrapelvic pressure an…
Multicenter Multireader Evaluation of an Artificial Intelligence-Based Attention Mapping System for the Detection of Prostate Cancer With Multiparame…
2020
OBJECTIVE. The purpose of this study was to evaluate in a multicenter dataset the performance of an artificial intelligence (AI) detection system with attention mapping compared with multiparametric MRI (mpMRI) interpretation in the detection of prostate cancer. MATERIALS AND METHODS. MRI examinations from five institutions were included in this study and were evaluated by nine readers. In the first round, readers evaluated mpMRI studies using the Prostate Imaging Reporting and Data System version 2. After 4 weeks, images were again presented to readers along with the AI-based detection system output. Readers accepted or rejected lesions within four AI-generated attention map boxes. Additio…
Aortic Function's Adaptation in Response to Exercise-Induced Stress Assessing by 1.5T MRI : A Pilot Study in Healthy Volunteers
2015
AIM:Evaluation of the aortic "elastic reserve" might be a relevant marker to assess the risk of aortic event. Our aim was to compare regional aortic elasticity at rest and during supine bicycle exercise at 1.5 T MRI in healthy individuals. METHODS:Fifteen volunteers (8 men), with a mean age of 29 (23-41) years, completed the entire protocol. Images were acquired immediately following maximal exercise. Retrospective cine sequences were acquired to assess compliance, distensibility, maximum rates of systolic distension and diastolic recoil at four different locations: ascending aorta, proximal descending aorta, distal descending aorta and aorta above the coeliac trunk level. Segmental aortic …
Improved contrast for myeloma focal lesions with T2-weighted Dixon images compared to T1-weighted images
2019
International audience; Purpose: The purpose of this study was twofold. First, to compare the contrast between spinal multiple myeloma (MM) focal lesions and surrounding bone marrow obtained on T2-weighted Dixon fat-only MR images to that obtained on T1-weighted spin-echo images. Second, to search for correlation between bone marrow fat fraction assessed by T2-weighted Dixon sequence and International Myeloma Working Group myeloma defining events.Materials and methods: A total of 39 patients with 112 focal MM lesions were included. There were 25 men and 14 women with a mean age of 68.8±9.8 [SD] years (range: 49-88 years). Contrast between focal MM lesions and surrounding bone marrow was cal…
Outcomes After Vascular Surgery Procedures in Patients with COVID-19 Infection: A National Multicenter Cohort Study (COVID-VAS)
2021
Objectives To analyze the outcome of vascular procedures performed in patients with COVID-19 infection during the 2020 pandemic. Methods This is a multicenter, prospective observational cohort study. We analyzed data from 75 patients with COVID-19 infection undergoing vascular surgery procedures in 17 hospitals across Spain and Andorra between March and May 2020. The primary end point was 30-day mortality. Clinical Trials registry number NCT04333693. Results The mean age was 70.9 (45–94) and 58 (77.0%) patients were male. Around 70.7% had postoperative complications, 36.0% of patients experienced respiratory failure, 22.7% acute renal failure, and 22.7% acute respiratory distress syndrome (…
Differentiation of benign and malignant lymph nodes in pediatric patients on ferumoxytol-enhanced PET/MRI.
2019
The composition of lymph nodes in pediatric patients is different from that in adults. Most notably, normal lymph nodes in children contain less macrophages. Therefore, previously described biodistributions of iron oxide nanoparticles in benign and malignant lymph nodes of adult patients may not apply to children. The purpose of our study was to evaluate if the iron supplement ferumoxytol improves the differentiation of benign and malignant lymph nodes in pediatric cancer patients on 18F-FDG PET/MRI. Methods: We conducted a prospective clinical trial from May 2015 to December 2018 to investigate the value of ferumoxytol nanoparticles for staging of children with cancer with 18F-FDG PET/MRI.…
Dose Estimation for the European Epidemiological Study on Pediatric Computed Tomography (EPI-CT).
2021
International audience; Within the European Epidemiological Study to Quantify Risks for Paediatric Computerized Tomography (EPI-CT study), a cohort was assembled comprising nearly one million children, adolescents and young adults who received over 1.4 million computed tomography (CT) examinations before 22 years of age in nine European countries from the late 1970s to 2014. Here we describe the methods used for, and the results of, organ dose estimations from CT scanning for the EPI-CT cohort members. Data on CT machine settings were obtained from national surveys, questionnaire data, and the Digital Imaging and Communications in Medicine (DICOM) headers of 437,249 individual CT scans. Exp…