Search results for "14(59)"

showing 9 items of 19 documents

Measurement Uncertainty of Harmonic Emission Indicators based on IEEE Std. 1459-2010

2020

The study presented in this paper is aimed at analyzing the measurement uncertainty impact on the evaluation of some power ratio parameters for harmonic emissions assessment based on IEEE Std. 1459-2010 apparent power decomposition. In addition to power factors for line utilization and harmonic pollution levels evaluation defined in the Standard, the study covers also some new parameters, which have been introduced by the authors as IEEE Std. 1459-2010 power quantities ratios. The measurement of the aforesaid parameters is implemented on a PC-based wattmeter, in order to investigate the measurement uncertainty impact on the evaluation of the power ratios. The obtained results show that, in …

Measurement uncertaintypower measurement02 engineering and technology01 natural scienceslaw.inventionlaw0202 electrical engineering electronic engineering information engineeringpollutionMedicineuncertainty analysisIEEE Std. 1459-2010Total harmonic distortionbusiness.industry020208 electrical & electronic engineering010401 analytical chemistryWattmeterpower qualityAC power0104 chemical sciencesReliability engineeringPower (physics)harmonic distortionPower definitionsHarmonic pollutionPower ratioharmonic analysisHarmonicMeasurement uncertaintybusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheHarmonic sources2020 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)
researchProduct

A single-point approach based on IEEE 1459-2000 for the identification of prevailing harmonic sources detection in distorted three phase power systems

2009

This paper deals with a novel single-point strategy for the detection of prevailing harmonic sources downstream or upstream the metering section in three-phase power systems. It is an enhancement of a previous strategy, already developed by the authors and it is based on the comparison of three non-active power quantities which are based on the IEEE Std. 1459-2000 approach. The method does not require any spectral analysis of voltages and currents because it is based only on the separation of the fundamental components from the harmonic content of voltage and current. In the paper, the effectiveness of the strategy is investigated by means of simulation tests which were carried out on a IEE…

Settore ING-INF/07 - Misure Elettriche E Elettronichepower measurements harmonic distortion reactive power power quality IEEE Std 1459
researchProduct

Individuazione dei carichi disturbanti nei sistemi di potenza. Una strategia basata su misure di potenze non attive

2010

Sorgenti armoniche potenze non attive IEEE 1459Settore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Polluting loads detection in power systems: a decision-making strategy based on nonactive power measurements

2010

In this paper a novel decision-making strategy is proposed for the detection of polluting loads in three-phase power systems. It makes use of simple indices, which are expressed as a function of some nonactive power quantities, previously proposed by the authors and derived from the approach of the IEEE Std. 1459–2000. The decision-making rules for the proposed strategy are presented and discussed, by means of some simulation tests.

Total harmonic distortionEngineeringbusiness.industryControl engineeringFunction (mathematics)AC powerPower (physics)power measurement harmonic distortion power definitions IEEE Std. 1459-2000 harmonic sourcesHarmonic analysisElectric power systemPower system simulationbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheVoltage
researchProduct

A time domain strategy for the measurement of IEEE Standard 1459-2000 power quantities in nonsinusoidal three-phase and single-phase systems

2008

This paper describes a time domain technique for the detection of fundamental and harmonic components of voltages and currents, which is able to evaluate all the quantities required by IEEE standard 1459-2000. The technique does not require any spectral analysis to separate the fundamental positive-sequence components from harmonic, negative-sequence and zero-sequence ones. In the paper the development of the proposed technique is presented for three-phase systems, both three-wires and four-wires, as well as for single-phase systems. The implementation of the proposed technique on a PC-based instrument is also described and experimental results are presented. Finally, accuracy specification…

Total harmonic distortionEngineeringbusiness.industryEnergy Engineering and Power TechnologyHarmonic distortion IEEE Standard 1459-2000 phase-locked loops (PLLs) power measurement power quality.Power (physics)Harmonic analysisPhase-locked loopThree-phasePersonal computerHarmonicElectronic engineeringTime domainElectrical and Electronic EngineeringbusinessSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Disturbing loads identification in power systems: a single-point time-domain method based on IEEE 1459-2000

2009

This paper presents a single-point method for the identification of prevailing disturbing loads in power systems for both single-phase and three-phase applications downstream or upstream from the metering section. It is based on the simultaneous measurement of three nonactive power quantities, which are based on the IEEE Std. 1459-2000 approach. The proposed method is only based on the separation of the fundamental components from the harmonic content of voltage and current; thus, it does not require any spectral analysis of the voltages and current. In this paper, the formulation of the proposed method and its time-domain implementation are described; moreover, some simulation results are …

Total harmonic distortionEngineeringbusiness.industrypower measurements harmonic distortion reactive power power systems power definitions power quality IEEE 1459AC powerPower (physics)Electric power systemHarmonicElectronic engineeringMetering modeUpstream (networking)Time domainElectrical and Electronic EngineeringbusinessInstrumentationSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Comparison of two different approaches for harmonic distortion sources assessment

2021

The paper focuses the attention on the comparison of two approaches for power quality assessment in the electric grid. Both approaches are suitable for investigating the harmonic pollution source and discovering if the harmonic source comes from the customer or the utility grid. The two approaches have the same purpose but they are deeply different. The first approach is based on the knowledge of the customer and utility equivalent impedance while the second is based on single point measurement at point of common coupling PCC. In this paper, the advantages and drawbacks of the two approaches are investigated also supported by a case study.

Total harmonic distortionHarmonic pollutionComputer scienceElectronic engineeringHarmonicPower qualityPoint of common couplingSingle pointGridEquivalent impedance transformsHarmonic Emission IEEE Std. 1459-2010 Power QualitySettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

IEEE Std. 1459 power quantities ratio approaches for simplified harmonic emissions assessment

2018

The paper investigates the suitability of using power ratio parameters for harmonic emissions assessment at the point of common coupling (PCC). The study is carried out starting from the IEEE Std. 1459-2010 apparent power decomposition, where power factors are defined for evaluating line utilization and harmonic pollution levels. In addition, the study investigates the behavior of new parameters, which are expressed in terms of ratio between IEEE Std. 1459-2010 power quantities. The study is carried out for both single-phase and three-phase case, also considering the presence of capacitors. ? 2018 IEEE.

harmonic sources; IEEE Std. 1459-2010; power definitions; power measurement; power quality020209 energy02 engineering and technologyAC powerAutomotive engineeringlaw.inventionPower (physics)harmonic distortionHarmonic analysisCapacitorHarmonic pollutionlawPower ratio0202 electrical engineering electronic engineering information engineeringHarmonicPoint of common couplingPower measurement harmonic distortion power definitions power quality IEEE Std. 1459-2010 harmonic sourcesSettore ING-INF/07 - Misure Elettriche E ElettronicheMathematics2018 18th International Conference on Harmonics and Quality of Power (ICHQP)
researchProduct

Harmonic sources detection in power systems via nonactive power measurements according to IEEE Std. 1459-2010: theoretical approach and experimental …

2010

In this paper an enhanced decision-making strategy is presented for the detection of harmonic sources in power systems able to detect also which is the prevailing nature of the disturbance (nonlinearity or unbalance). It makes use of some simple indices, which are evaluated by means of the measurements of some nonactive power quantities, proposed by the authors and derived from the approach of the IEEE Std. 1459-2010. The decision-making rules for the proposed strategy are presented and discussed by means of simulation and experimental tests. The results obtained are presented, showing the effectiveness of the proposed strategy for the detection of the dominant harmonic source upstream or d…

power measurement harmonic distortion power definitions IEEE Std. 1459-2010 harmonic sourcesSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct