Search results for "20(60)"
showing 10 items of 368 documents
Development of a self-pumping extracorporeal blood oxygenation device characterized by a rotating shaft with embedded fiber packages.
2019
Introduction: To offer respiratory support for patients with lung disease, a novel technological solution for blood pumping and oxygenation is being developed. The pump–lung system was designed to integrate fiber membranes into six packages radially embedded in a rotating hollow shaft placed along the longitudinal axis of the device. Fiber packages are inclined with respect to the rotation axis so that the rotational motion of the rotating shaft allows a self-pumping system to be obtained. Method: Both hemodynamic and gas transfer performances were investigated using both in vitro experiments and in silico flow analyses. Results: The predicted flow velocity in the pump chamber was smooth an…
Retrospective study of the bone morphology in the posterior mandibular region. Evaluation of the prevalence and the degree of lingual concavity and t…
2016
Background In order to choose the appropriate implant size and to prevent complications, an oral surgeon must know the size and shape of the mandible. In the posterior mandibular region, a lingual undercut is often found and could represent a difficulty hard to manage if a lingual or buccal perforation occur. A large series of computed tomography (CT) images of the mandibular first molar was evaluated and the bone morphology, the prevalence and the degree of the lingual concavity in the first molar region were studied. Material and Methods One hundred and fifty-one computed tomography (CT) examinations of patients were retrospectively evaluated to determine anatomical variations in bone mor…
Modeling Right Ventricle Failure After Continuous Flow Left Ventricular Assist Device: A Biventricular Finite-Element and Lumped-Parameter Analysis
2017
The risk of right ventricle (RV) failure remains a major contraindication for continuous-flow left ventricular assist device (CF-LVAD) implantation in patients with heart failure. It is therefore critical to identify the patients who will benefit from early intervention to avoid adverse outcomes. We sought to advance the computational modeling description of the mechanisms underlying RV failure in LVAD-supported patients. RV failure was studied by computational modeling of hemodynamic and cardiac mechanics using lumped-parameter and biventricular finite element (FE) analysis. Findings were validated by comparison of bi-dimensional speckle-tracking echocardiographic strain assessment of the …
Postural control and physiological responses to a simulated match in U-20 judo competitors
2018
The aim was to evaluate the effects of judo combat on the athletes’ postural control (PC) and physiological loading before, during and after a simulated match. Seventeen under-20 regional and national level athletes completed one modified 7-min match. At baseline, during the combat (3rd and 7th minutes) and 2-min post-match centre of pressure (CoP) parameters were assessed. Heart rate (HR), blood lactate (BLa) and rating of perceived exertion (RPE) and local RPE (LRPE) were collected. Significant increments were observed in CoP mean positioning and velocity at 3rd and 7th minutes, but the CoP deviation in both axes was unaffected. HR and BLa were elevated at 3rd and 7th minutes, and they re…
In Vivo Strain Analysis of Dilated Ascending Thoracic Aorta by ECG-Gated CT Angiographic Imaging
2017
Accurate assessment of aortic extensibility is a requisite first step for elucidating the pathophysiology of an ascending thoracic aortic aneurysm (ATAA). This study aimed to develop a framework for the in vivo evaluation of the full-field distribution of the aortic wall strain by imaging analysis of electrocardiographic- (ECG) gated thoracic data of 34 patients with ATAA. Seven healthy controls (i.e., non-aneurysmal aorta) from patients who underwent ECG-gated CT angiography for coronary artery diseases were included for comparison. To evaluate the systolic function, ECG-gated computed tomography (CT) angiography was used to generate patient-specific geometric meshes of the ascending aorta…
A Human-Humanoid Interaction Through the Use of BCI for Locked-In ALS Patients Using Neuro-Biological Feedback Fusion.
2018
This paper illustrates a new architecture for a human–humanoid interaction based on EEG-brain computer interface (EEG-BCI) for patients affected by locked-in syndrome caused by Amyotrophic Lateral Sclerosis (ALS). The proposed architecture is able to recognise users’ mental state accordingly to the biofeedback factor $\text {B}_{\text f}$ , based on users’ attention, intention, and focus, that is used to elicit a robot to perform customised behaviours. Experiments have been conducted with a population of eight subjects: four ALS patients in a near locked-in status with normal ocular movement and four healthy control subjects enrolled for age, education, and computer expertise. The results s…
Composing only by thought: Novel application of the P300 brain-computer interface.
2017
The P300 event-related potential is a well-known pattern in the electroencephalogram (EEG). This kind of brain signal is used for many different brain-computer interface (BCI) applications, e.g., spellers, environmental controllers, web browsers, or for painting. In recent times, BCI systems are mature enough to leave the laboratories to be used by the end-users, namely severely disabled people. Therefore, new challenges arise and the systems should be implemented and evaluated according to user-centered design (USD) guidelines. We developed and implemented a new system that utilizes the P300 pattern to compose music. Our Brain Composing system consists of three parts: the EEG acquisition d…
A cell-free approach with a supporting biomaterial in the form of dispersed microspheres induces hyaline cartilage formation in a rabbit knee model
2020
The objective of this study was to test a regenerative medicine strategy for the regeneration of articular cartilage. This approach combines microfracture of the subchondral bone with the implant at the site of the cartilage defect of a supporting biomaterial in the form of microspheres aimed at creating an adequate biomechanical environment for the differentiation of the mesenchymal stem cells that migrate from the bone marrow. The possible inflammatory response to these biomaterials was previously studied by means of the culture of RAW264.7 macrophages. The microspheres were implanted in a 3 mm-diameter defect in the trochlea of the femoral condyle of New Zealand rabbits, covering them wi…
Simulation study of transcatheter heart valve implantation in patients with stenotic bicuspid aortic valve
2019
Bicuspid aortic valve (BAV) anatomy has routinely been considered an exclusion in the setting of transcatheter aortic valve implantation (TAVI) because of the large dimension of the aortic annulus having a more calcified, bulky, and irregular shape. The study aims to develop a patient-specific computational framework to virtually simulate TAVI in stenotic BAV patients using the Edwards SAPIEN 3 valve (S3) and its improved version SAPIEN 3 Ultra and quantify stent frame deformity as well as the severity of paravalvular leakage (PVL). Specifically, the aortic root anatomy of n.9 BAV patients who underwent TAVI was reconstructed from pre-operative CT imaging. Crimping and deployment of S3 fram…
Basic cardiovascular variability signals: mutual directed interactions explored in the information domain.
2017
The study of short-term cardiovascular interactions is classically performed through the bivariate analysis of the interactions between the beat-to-beat variability of heart period (RR interval from the ECG) and systolic blood pressure (SBP). Recent progress in the development of multivariate time series analysis methods is making it possible to explore how directed interactions between two signals change in the context of networks including other coupled signals. Exploiting these advances, the present study aims at assessing directional cardiovascular interactions among the basic variability signals of RR, SBP and diastolic blood pressure (DBP), using an approach which allows direct compar…