Search results for "31"
showing 10 items of 4401 documents
PD characteristics at Square Shaped Voltages Applying Two Different Detecting Techniques
2016
Nowadays power electronic converters are widely used and the fast switching voltage fronts results in an increased stress on the insulation material and may cause a reduction of the HV systems reliability. Nonsinusoidal voltage waveform have influence on the partial discharges (PD) characteristics in insulating systems due to the increased harmonic content which causes problems mainly in electrical PD measurement setups. In fact, impulse voltages cause strong switching disturbances, which make it much more difficult to distinguish PD signals from noise. This work investigates the influence of repetitive steep pulses on different types of test objects exposed to square wave voltages applying…
Partial discharges at different voltage waveshapes: Comparison between two different acquisition systems
2018
In modern HV apparatuses the wide use of electronic converters, increase the stress on the involved insulation systems and thus affect the reliability of the whole power grid. Additionally, such non-sinusoidal voltage shapes contain high gradient flanks that create problems in the detection of partial discharge (PD) activity. The aim of this paper is to discuss the methodology on how to suitably approach PD detection in insulation systems exposed to various voltage waveshapes in general by comparing two different measuring systems. The first one, equipped with a resonant PD decoupler, designed specifically for detection at typical power electronic waveshapes and the other one, based on an a…
Space charge behavior of different insulating materials employed in AC and DC cable systems
2017
In this work, the space charge accumulation in three different XLPE based material has been carried out by using the PEA (Pulsed Electro-Acoustic) method. The specimens provided by a cables industry have been subjected to the same DC stress during polarization time at environment temperature. Afterwards, the high voltage generator has been turned off and the amount residual charge has been evaluated. The space charge profiles during polarization and depolarization have been carried out and compared. Finally, the distribution of electric field within the samples has been reported. In particular, the maximum distortion of electric field has been calculated by taking into account the distribut…
Space charge accumulation in undersea HVDC cables as function of heat exchange conditions at the boundaries – water-air interface
2020
Transmission lines with undersea HVDC cables are an interesting technological solution for the supply of electrical energy to islands. The accumulation of space charge inside the dielectric layer of a HVDC cable is one of the most important element to consider in its design and during operation. The formation of space charge is due to various factors including the high dependence on the temperature of the electrical conductivity of the insulation and the establishment of a thermal gradient under load conditions. This research is focused on the space charge accumulation phenomenon around a section of a HVDC cable half dipped in water and half in air. Due to the high difference in thermal con…
Contributed Review: Review of thermal methods for space charge measurement.
2016
The space charge accumulation phenomenon has garnered great interest over the last two decades because of the increased use of direct current in high voltage electrical systems. In this context, a significant relevance has been achieved by the thermal methods, used for solid dielectrics. This paper presents a review of this non-destructive measurement system used for the measurement of space charge. The thermal pulse method, the thermal step method, and the laser intensity modulation method are described. For each configuration, the principle of operation, the thicknesses analyzed, and the spatial resolution are described, reporting also the main related applications
Space Charge Measurement under DC and DC Periodic Waveform
2018
In High Voltage systems, Partial Discharges (PDs) monitoring are one of the main diagnostic instrument to evaluate the reliability of the apparatus. Under Alternating Current (AC) stress, PDs detection and recognition techniques are well consolidated. On the contrary, the monitoring of PDs under Direct Current (DC) stress is difficult due to complexities related to the nature of the phenomenon, which cause the beginning of PDs events in proximity of the dielectric breakdown. This problem has been partially overcome by using a continuous Periodic waveform (DCP) with positive average value, as described in a recent published work. Under DC stress, another degradation factor is the Space Charg…
Space Charges and Partial Discharges Simultaneous Measurements under DC Stress
2016
In the field of HVDC, the main causes of insulation aging are due to the space charge and PD phenomena. In particular, the purpose of the present work is to verify a possibility to measure simultaneously the space charge and the PDs under DC stress in order to evaluate the correlation between both phenomena. The space charge was measured by using a modified PEA cell and PDs were measured by using a novel wireless sensor system. The space charge profile and the PD pulses carried out simultaneously have been reported and discussed.
Partial discharge of gel insulated high voltage power modules subjected to unconventional voltage waveforms
2016
Performances and duration of the new generation of high voltage power electronic components are dependent on dielectric materials aim to insulating their internal terminals. The presence of defects, some due to faults generated during the manufacturing process, but also due to the internal design of layers and connections, can cause local enhancements of electric field and consequently possible activity of partial discharges phenomena or other effects (aging, tracking) that may result in reduction of device reliability. Furthermore, the usage of unconventional voltage waveforms, like square waves or pulse width modulated waves, additionally increases the electrical aging of the insulation s…
Partial discharge detection and localization along medium voltage cables
2017
In the last years different partial discharge (PD) measuring techniques have been developed because PD diagnostic is the most widely tool to evaluate the insulation condition of a power cable. Recently non-conventional methods and sensors have been used in order to reach improved results in PD measurements. The purpose of this work is to perform measurements that allow to study the variation of pulses when they travel along a MV cable and to locate the pulse source through the time arrival difference of the pulses obtained from two sensors installed separately.
Deformation of bubbles in silicon gel insulation under an alternating electric field
2019
The behavior of silicone gel under electrical stress plays a significant role in the reliability and durability of high voltage electronic power devices due to its widespread use for the insulation of IGBT modules and other components. The charges accumulation at the bubble boundaries leads to significant displacements due to the establishment of Coulombic forces and the high deformability of colloidal system. The main purpose of this work is to validate a numerical approach useful to investigate, for a given silicone gel, the non-linear relation between the applied HVDC stress and the electric field over an air bubble within the insulation bulk. The analysis has been carried out by means o…