Forecasting energy output of a solar power plant in curtailment condition based on LSTM using P/GHI coefficient and validation in training process, a…
2022
This study presents how to improve the short-term forecast of photovoltaic plant's output power by applying the Long Short-Term Memory, LSTM, neural networks for industrial-scale solar power plants in Vietnam under possible curtailment operation. Since the actual output power does not correspond to the available power, new techniques (Global Horizontal Irradiance - GHI interval division, P/GHI factor addition (P - Power)) have been designed and applied for processing errors and missing data. The prediction model (LSTM network, structure of hidden layers, number of nodes) has been developed by the authors in a previous work. In this new version of the model, the training technique is improve…
A Multi-Port Approach to Solve Distribution Networks with Meshes and PV Nodes
2007
A new methodology based on the backward/forward (b/f) technique for the load flow solution in distribution systems is here proposed. The methodology takes efficiently into account the fixed voltage nodes and uses a reduced bus impedance matrix. In this way, it is possible to attain, for the unknowns at the PV nodes, the same values that are attainable solving the network with the methods adopted for transmission systems. With the same methodology it is possible to take into account also the meshes. If the network contains only meshes, the relevant model is linear and it is the one including the compensation currents. The presence of PV nodes introduces non linearity in the model and an iter…
Valutazioni economiche e incentivi
2009
Approccio allo Sviluppo di Sistemi Diagnostici per il Funzionamento Fault Tolerant delle Micro-grid
2009
Il progressivo aumento del livello di penetrazione della generazione distribuita(GD) è destinato a provocare un profondo mutamento nelle esistenti reti di distribuzione che non sono più considerate come terminazioni passive del sistema elettrico complessivo. Una soluzione possibile è quella relativa alla realizzazione di piccole reti, le micro-grid, che riproducono, al loro interno, la struttura del sistema di produzione e distribuzione dell’energia elettrica. Per ottenere una adeguata affidabilità della micro-grid risulta importante la individuazione e la gestione dei guasti ai fini del perseguimento dell’esercizio "fault tolerant" della micro-grid stessa. Nel presente lavoro, dopo aver in…
No-Load Energization of Very Long EHV Mixed Overhead-Cable Lines
2010
Multi-objective long term optimal dispatch of distributed energy resources in micro-grids
2010
The amount of distributed generators in power distribution systems is evermore increasing, and the potential benefits and drawbacks are becoming clearer. The optimal management of Distributed Energy Resources (DER) in microgrids is essential to guarantee their best exploitation. Optimal operation allows to maximize their benefits, such as reduction of network energy losses, reduction of carbon emissions and to minimize the negative effects of a strong DER penetration, such as the increase of infrastructural investment and operational costs. Hence, DER management is a multi-objective problem in which many objectives of interest, often conflicting, need to be optimized simultaneously. In this…
Earthing System's Design in presence of non-uniform soil
2007
The Authors propose a practical approach for facing the problem of the design of the earthing systems in two-layer soils. The approach is based on the calculation of an equivalent resistivity of the non-uniform soil through which the designer can treat this one as it was uniform. The purpose of the Authors is to provide an innovative simple method and some easy-to-use graphs for an easy earthing systems’ design in two-layer soils.
Multi-objective Optimization of Energy Hubs at the Crossroad of Three Energy Distribution Networks
2016
This paper provides a multi-objective optimization framework aimed at the management of a multi-carrier energy system involving both electricity and hydrogen. Using the concept of the multi-carrier hub, the proposed system has been modelled in order to define completely every energy flow inside the plant. After that, a heuristic multi-objective optimization algorithm, the Non-dominated Sorting Genetic Algorithm II, has been implemented for the energy management of the plant, taking into account simultaneously three different objective functions related to economic and technical goals. This optimization process provides the set point defining the working configuration of the plant for a dayl…
Ottimizzazione Multi-Obiettivo delle Prestazioni Energetiche e Ambientali di un Edificio Residenziale
2019
Il presente lavoro, svolto nell’ambito dell’Annex 72 dell’International Energy Agency, descrive un approccio metodologico volto all’identificazione di interventi ottimali di ristrutturazione da effettuare sull’involucro di un edificio residenziale, permettendo di minimizzare contemporaneamente quattro funzioni obiettivo: i consumi energetici in fase d’uso, i costi d’investimento e gli impatti energetici e ambientali di ciclo di vita. L’ottimizzazione, eseguita tramite un algoritmo multi-obiettivo, ha permesso di identificare gli spessori di materiale isolante e di materiali massivi da aggiungere sul tetto e sulle pareti perimetrali dell’involucro edilizio per minimizzare le quattro funzioni…
Methodologies to uprate an overhead line. Italian TSO case study
2013
The amount of wind power and other time-variable non-dispatchable electricity generation is rapidly increasing across the world, causing a significant change in the electrical system configuration. The existing structural asset isn't adequate to dispatch these new power that have a priority in the energy dispatching. In addiction the outage of substations on the grid and the increase of consumptions have caused growing load currents. In order to satisfy these needs, TSOs have adopted new measures on existing power lines and N-1 criteria to ensures the electrical grid security. These particular devices are Dynamic Thermal Rating (DTR) systems. After introducing thermal resistant conductors a…