Search results for "530"
showing 10 items of 1476 documents
Measurement of the 241Am neutron capture cross section at the n-TOF facility at CERN
2016
New neutron cross section measurements of minor actinides have been performed recently in order to reduce the uncertainties in the evaluated data, which is important for the design of advanced nuclear reactors and, in particular, for determining their performance in the transmutation of nuclear waste. We have measured the 241 Am(n,γ) cross section at the n TOF facility between 0.2 eV and 10 keV with a BaF2 Total Absorption Calorimeter, and the analysis of the measurement has been recently concluded. Our results are in reasonable agreement below 20 eV with the ones published by C. Lampoudis et al. in 2013, who reported a 22% larger capture cross section up to 110 eV compared to experimental …
Exclusive measurements of nuclear breakup reactions of 17Ne
2014
F. Wamers et al.; 4 pags.; 2 figs. Open Access funded by Creative Commons Atribution Licence 2.0
Variable masses in fission and heavy-ion collisions
1972
With the use of the cranking formula, the coordinate-dependent mass parameters of the kinetic-energy operator in fission processes and heavy-ion collisions are calculated in the two-center oscillator model. It is shown that the reduced mass and also the classical moment of inertia are obtained for large separations of the fragments. For small separations, however, the mass parameter for the motion of the centers of mass of the fragments is larger than the reduced mass by an order of magnitude.
The 33S(n,α)30Si cross section measurement at n TOF-EAR2 (CERN): From 0.01 eV to the resonance region
2017
The 33S(n,α)30Si cross section measurement, using 10B(n,α) as reference, at the n TOF Experimental Area 2 (EAR2) facility at CERN is presented. Data from 0.01 eV to 100 keV are provided and, for the first time, the cross section is measured in the range from 0.01 eV to 10 keV. These data may be used for a future evaluation of the cross section because present evaluations exhibit large discrepancies. The 33S(n,α)30Si reaction is of interest in medical physics because of its possible use as a cooperative target to boron in Neutron Capture Therapy (NCT).
High precision measurement of the radiative capture cross section of 238U at the n_TOF CERN facility
2016
The importance of improving the accuracy on the capture cross-section of 238U has been addressed by the Nuclear Energy Agency, since its uncertainty significantly affects the uncertainties of key design parameters for both fast and thermal nuclear reactors. Within the 7th framework programme ANDES of the European Commission three different measurements have been carried out with the aim of providing the 238U(n,γ) cross-section with an accuracy which varies from 1 to 5%, depending on the energy range. Hereby the final results of the measurement performed at the n-TOF CERN facility in a wide energy range from 1 eV to 700 keV will be presented. © The Authors, published by EDP Sciences, 2017.
The 236U neutron capture cross-section measured at the n TOF CERN facility
2016
International audience; The $^{236}$U isotope plays an important role in nuclear systems, both for future and currently operating ones. The actual knowledge of the capture reaction of this isotope is satisfactory in the thermal region, but it is considered insufficient for Fast Reactor and ADS applications. For this reason the $^{236} \text{U}(n, \gamma)$ reaction cross-section has been measured for the first time in the whole energy region from thermal energy up to 1 MeV at the n_TOF facility with two different detection systems: an array of C$_6$D$_6$ detectors, employing the total energy deposited method, and a 4$\pi$ total absorption calorimeter (TAC), made of 40 BaF$_2$ crystals. The t…
New measurement of the 242Pu(n,γ) cross section at n-TOF-EAR1 for MOX fuels: Preliminary results in the RRR
2016
The spent fuel of current nuclear reactors contains fissile plutonium isotopes that can be combined with 238U to make mixed oxide (MOX) fuel. In this way the Pu from spent fuel is used in a new reactor cycle, contributing to the long-term sustainability of nuclear energy. The use of MOX fuels in thermal and fast reactors requires accurate capture and fission cross sections. For the particular case of 242Pu, the previous neutron capture cross section measurements were made in the 70’s, providing an uncertainty of about 35% in the keV region. In this context, the Nuclear Energy Agency recommends in its “High Priority Request List” and its report WPEC-26 that the capture cross section of 242Pu…
The BaBar detector: Upgrades, operation and performance
2013
The BABAR detector operated successfully at the PEP-Il asymmetric e(+) e(-) collider at the SLAC National Accelerator Laboratory from 1999 to 2008. This report covers upgrades, operation, and performance of the collider and the detector systems, as well as the trigger, online and offline computing, and aspects of event reconstruction since the beginning of data taking.
Optical Imaging and Spectroscopy of Atomically Precise Armchair Graphene Nanoribbons
2019
We report the optical imaging and absorption spectroscopy on atomically precise armchair graphene nanoribbons (GNRs) on insulating fused silica substrates. This is achieved by controlling light polarization on macroscopically aligned GNRs which greatly enhances the optical contrast of the submonolayer GNRs on the insulating substrates. We measure the linear absorption spectra of 7-armchair and 9-armchair GNRs in this study, and the experimental data agree qualitatively with ab inito calculation results. The polarization spectroscopy technique enables an unambiguous optical identification of GNRs and provides a rapid tool to characterize the transferred film over a large area.
Generation of localized pulses from incoherent wave in optical fiber lines made of concatenated Mamyshev regenerators
2008
International audience; We investigate the novel properties of optical fiber lines made of Mamyshev regenerators (MRs) based on self-phase modulation and subsequent spectral filtering. In particular, we show that such a regenerator line can be used to generate random sequences of optical pulses from an incoherent wave. This behavior is related to the existence of stable eigenpulses that can propagate unchanged through the regenerator line and act as attractors for incoming pulses. By changing the regenerator parameters, we also report the existence of multiple eigenpulses and limit cycles. Finally, we demonstrate that MRs could be used as efficient nonlinear gates in fiber laser cavities.