Search results for "7(15)"
showing 10 items of 142 documents
Komparativno istraživanje oblikovanja četiriju rotirajućih sustava
2015
Svrha: U ovom istraživanju analizirali smo rezno područje, vrijeme instrumentacije, održavanje anatomije korijenskog kanala i neinstrumentirana područja dobivena korištenjem instrumenata F360®, Mtwo®, RaCe® i Hyflex® u ISO veličini 35. Materijali i metode: Odabrano je 120 zuba s jednim ravnim kanalom i podijeljeni su u četiri grupe. Radna duljina određena je radiološki. Zubi su rezani dijamantnim diskom, a presjeci su promatrani stereoskopskim mikroskopom Nikon SMZ-2T pod svjetiljkom Intralux 4000-1. Grupe su oblikovane predoperativnom analizom AutoCAD. Zubi su rekonstruirani s pomoću K-proširivača #10 i epoksi ljepila. Svaka grupa instrumentirana je jednim od četiriju sustava. Vrijeme inst…
In-vitro fatigue and fracture performance of three different ferrulized implant connections used in fixed prosthesis
2021
Background/purpose: The aim of the present in vitro study was to evaluate fatigue resistance of dental fixtures in three different types of fixture/abutment finishing line. Materials and methods: Transmucosal dental implants, with or without ferrulized neck, underwent fatigue tests (static and dynamic load) using the following standard protocol: UNI EN ISO 14801:2016. Two types of loading devices (screw- or cement-retained restoration) were also tested, and fatigue cycle tests were run to failure. Data of static and dynamic load tests were analyzed by proper statistical methods. Results: Following standard protocol for fatigue testing, the ILC type (Implant Level with ferrulized neck and ce…
Comparison of Shaping Ability of 10 Rotary and Reciprocating Systems: an In Vitro Study with AutoCAD
2017
Cilj: Usporediti reznu površinu, očuvanje anatomije korijenskog kanala i neinstrumentiranu površinu nakon instrumentacije sustavima F360®, F6SkyTaper®, HyflexEDM®, iRace®, Neoniti®, O.Shape®, P.Next®, Reciproc®, Revo-S® i WaveOneGold® s veličinom instrumenta 25. Materijali i metode: Tristo zubi s jednim ravnim korijenom i okruglim ili eliptičnim presjekom korijenskog kanala podijeljeno je u 10 skupina (1-F360®, 2-F6SkyTaper®, 3-HyflexEDM®, 4-iRace®, 5-Neoniti®, 6-O Shape®, 7-P.Next®, 8-Reciproc®, 9-Revo-S® i 10-WaveOneGold®) i poprečno prerezano na trećine ultrafinim reznim diskovima. Uzorci su fotografirani pod stereomikroskopom i provedena je predinstrumentacijska analiza prije ponovnog s…
Apport de matières organiques exogènes en agriculture: indicateur de potentialité de stockage de carbone dans les sols et définition de classes de di…
2007
CT3; absent
Adjuvant Effect of Titanium Brushes in Peri-Implant Surgical Treatment: A Systematic Review
2021
Background: the prognosis of peri-implant surgery can be affected by poor decontamination of the implant surface, which could be improved with the use of titanium brushes. The objectives of this systematic review were to evaluate the effectiveness of titanium brushes in the decontamination of the implant surface in terms of plaque index, probing depth, bleeding on probing and bone loss/gain; as well as its effectiveness according to the type of peri-implant bone defect. Methods: an electronic search was carried out in the PubMed, Scopus, Cochrane and Embase databases, as well as a manual search. The search strategy included four keywords: “Peri-implantitis”, “Periimplantitis”, “Implant Surf…
Laser Therapy for Infected Sites and Immediate Dental Implants in the Esthetic Zone: A Case Report and Review of Literature
2020
Placement of postextraction dental implants has become a common practice. Here, we reviewed current literature, along with clinical procedures, outcomes, and incidence of complications, associated with immediate implants in infected postextraction sites. The YSGG (yttrium, scandium, gallium, and garnet) laser can significantly reduce the bacterial concentration after extracting a compromised tooth. We treated a 40-year-old woman with a compromised tooth in the esthetic zone, presenting clinical and radiological signs of infection, particularly a periapical periodontitis. The tooth was extracted after administering local anesthesia using Optocain® (mepivacaine and adrenalin 1 : 100,000), fol…
Can turbulence within the field of view cause significant biases in radiative transfer modeling at the 183 GHz band?
2018
The hypothesis whether turbulence within the passive microwave sounders field of view can cause significant biases in radiative transfer modeling at the 183 GHz water vapor absorption band is tested. A novel method to calculate the effects of turbulence in radiative transfer modeling is presented. It is shown that the turbulent nature of water vapor in the atmosphere can be a critical component of radiative transfer modeling in this band. Radiative transfer simulations are performed comparing a uniform field with a turbulent one. These comparisons show frequency dependent biases which can be up to several kelvin in brightness temperature. These biases can match experimentally observe…
HOLIMO II: a digital holographic instrument for ground-based in situ observations of microphysical properties of mixed-phase clouds
2013
Measurements of the microphysical properties of mixed-phase clouds with high spatial resolution are important to understand the processes inside these clouds. This work describes the design and characterization of the newly developed ground-based field instrument HOLIMO II (HOLographic Imager for Microscopic Objects II). HOLIMO II uses digital in-line holography to in situ image cloud particles in a well-defined sample volume. By an automated algorithm, two-dimensional images of single cloud particles between 6 and 250 μm in diameter are obtained and the size spectrum, the concentration and water content of clouds are calculated. By testing the sizing algorithm with monosized beads a system…
Development of a Bioaerosol single particle detector (BIO IN) for the Fast Ice Nucleus CHamber FINCH
2010
Abstract. In this work we present the setup and first tests of our new BIO IN detector. This detector was constructed to classify atmospheric ice nuclei (IN) for their biological content. It is designed to be coupled to the Fast Ice Nucleus CHamber FINCH. If one particle acts as an ice nucleus, it will be at least partly covered with ice at the end of the development section of the FINCH chamber. The device combines an auto-fluorescence detector and a circular depolarization detector for simultaneous detection of biological material and discrimination between water droplets, ice crystals and non activated large aerosol particles. The excitation of biological material with UV light and analy…
Monuments à la régence. Représentations sculptées d’Anne d’Autriche et imaginaire du pouvoir
2020
Actes du colloque "La représentation sculpturale du pouvoir. La France, l'Italie et leur rayonnement en Europe à l'époque moderne" organisé par l'Ecole pratique des hautes études et la Société historique et littéraire polonaise, Paris, Bibliothèque polonaise, 17-18 mars 2016; International audience