Search results for "ABDOMINAL AORTIC ANEURYSM"

showing 10 items of 81 documents

Endovascular versus open surgical repair of abdominal aortic aneurysm with concomitant malignancy

2007

Background The management of patients with abdominal aortic aneurysm (AAA) and concurrent malignancy is controversial. This study retrospectively assessed the outcome of endovascular repair (EVAR) and open repair (OR) for the treatment of AAA in patients undergoing curative treatment for concomitant malignancies. Methods All patients who underwent surgery for a nonruptured infrarenal AAA of ≥5.5 cm and concomitant malignancy between 1997 and 2005 were retrospectively reviewed. Results Identified were 25 patients (22 men; mean age, 70.3 years) with nonruptured infrarenal AAA of ≥5.5 cm (mean size, 6.4 cm) and concomitant malignancy amenable for curative treatment. EVAR was used to treat 11 p…

Malemedicine.medical_specialtyTime FactorsTime FactorKaplan-Meier EstimateMalignancySettore MED/22 - Chirurgia VascolareFollow-Up StudieAortic aneurysmAneurysmPostoperative Complicationsabdominal aortic aneurysmRetrospective StudieNeoplasmsmedicineHumansEVARAgedRetrospective StudiesAged 80 and overbusiness.industryMortality rateOpen repairGreat BritainRetrospective cohort studyLength of StayMiddle Agedmedicine.diseaseAbdominal aortic aneurysmUnited KingdomSurgeryTreatment OutcomeItalyConcomitantNeoplasmFemaleSurgeryRadiologyPostoperative ComplicationbusinessCardiology and Cardiovascular MedicineVascular Surgical ProceduresAbdominal surgeryHumanAortic Aneurysm AbdominalFollow-Up StudiesmalignancyJournal of Vascular Surgery
researchProduct

Initial Clinical Experience Using the Low-Profile Altura Endograft System With Double D-Shaped Proximal Stents for Endovascular Aneurysm Repair.

2018

Purpose: To report the initial clinical results of endovascular aneurysm repair (EVAR) using the low-profile (14-F) Altura Endograft System, which features a double “D-shaped” stent design with suprarenal fixation and modular iliac components that are deployed from distal to proximal. Methods: From 2011 to 2015, 90 patients (mean age 72.8±8.3 years; 79 men) with abdominal aortic aneurysm (AAA; mean diameter 53.8±5.7 mm) were treated at 10 clinical sites in 2 prospective, controlled clinical studies using the Altura endograft. Outcomes evaluated included mortality, major adverse events (MAEs: all-cause death, stroke, paraplegia, myocardial infarction, respiratory failure, bowel ischemia, an…

Malemedicine.medical_specialtyTime Factorsmedicine.medical_treatment030204 cardiovascular system & hematologyProsthesis DesignEndovascular aneurysm repairRisk Assessment03 medical and health sciencesBlood Vessel Prosthesis Implantation0302 clinical medicinePostoperative ComplicationsRisk FactorsmedicineHumansRadiology Nuclear Medicine and imaging030212 general & internal medicineMyocardial infarctionAdverse effectStrokeAgedAged 80 and overbusiness.industryPatient SelectionEndovascular ProceduresMiddle Agedmedicine.diseaseThrombosisAbdominal aortic aneurysmSurgeryBlood Vessel ProsthesisProsthesis FailureTreatment OutcomeRespiratory failureSurgeryFemaleStentsCardiology and Cardiovascular MedicineParaplegiabusinessAortic Aneurysm AbdominalJournal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
researchProduct

An abdominal aortic aneurysm (AAA) in combination with duplication of the inferior vena cava (IVC), the right renal artery (RRA) and the right renal …

1990

Intra-abdominal abnormality of vessels may sometimes lead to complications. A case of the rare combination of an abdominal aortic aneurysm (AAA) at the origin of the inferior mesenteric a. with duplications of the inferior vena cava (IVC), the right renal a. (RRA) and the right renal v. (RRV) as well as absence of the left common iliac v. is reported.

Malemedicine.medical_specialtyVena Cava InferiorRight renalInferior vena cavaRenal VeinsPathology and Forensic MedicineRenal ArteryInternal medicineGene duplicationmedicineHumansAbnormalities MultipleRadiology Nuclear Medicine and imagingAorta Abdominalcardiovascular diseasesRight Renal ArteryAgedRight renal veinbusiness.industrymedicine.diseaseAbdominal aortic aneurysmAortic Aneurysmmedicine.veincardiovascular systemCardiologySurgeryAnatomybusinessSurgical and Radiologic Anatomy
researchProduct

MDCT and virtual angioscopy in spontaneous aortocaval fistula

2007

Aortocaval fistula is a rare, less than 1%, but life threatening complication, of abdominal aortic aneurysm. Mortality is high but prompt recognition of the fistula can reduce mortality rate. The multidetector row CT (MDCT) findings in a 69-year-old patient with a complex medical history characterized by previous episodes of myocardial ischemia, is reported. MDCT shows an early homogeneous enhancement of the inferior vena cava, slightly dilated at the liver level and markedly narrowed above the renal vein due to aneurysm compression. The patient underwent to emergency laparotomy but died during surgery for cardiac arrest. MDCT allows a prompt recognition of the fistula and different compute…

Malemedicine.medical_specialtymedicine.medical_treatmentFistulaAngioscopyVena Cava InferiorInferior vena cavaAortographyAortic aneurysmUser-Computer InterfaceAneurysmFatal OutcomeImaging Three-DimensionalcavaLaparotomymedicineHumansfistulaRadiology Nuclear Medicine and imagingcardiovascular diseasesAgedMDCT angioscopymedicine.diagnostic_testbusiness.industryvirtual angioscopyPhlebographymedicine.diseaseAngioscopyAbdominal aortic aneurysmaortamultidetector row ctmedicine.veinArteriovenous Fistulacardiovascular systemRadiographic Image Interpretation Computer-AssistedRadiologyRenal veinCardiology and Cardiovascular MedicinebusinessTomography X-Ray ComputedVascular Surgical Proceduresaorta; cava; fistula; multidetector row ct; virtual angioscopyAortic Aneurysm Abdominal
researchProduct

Histamine release in mesenteric traction syndrome during abdominal aortic aneurysm surgery: prophylaxis with H1 and H2 antihistamines

2002

Objective and design: Mesenteric traction syndrome is described as sudden tachycardia, hypotension and flush. Among other etiological factors eventeration or mesenteric traction of the small intestine may cause histamine release from mesenteric mast cells. We hypothesized that mesenteric traction syndrome may be positively influenced by prophylactic antihistamine administration.¶Methods: Male patients (n = 17, ASA groups III-IV, 48–78 years old) were investigated in a randomised double blind study during elective abdominal aortic aneurysm (AAA) repair. Eight patients had pre-anaesthetic prophylaxis with dimetindene (H1-receptor antagonist) plus cimetidine (H2-receptor antagonist), 9 patient…

Malemedicine.medical_specialtymedicine.medical_treatmentImmunologyBlood PressurePlaceboHistamine Releasechemistry.chemical_compoundDouble-Blind MethodHeart RateTachycardiaFlushingmedicineDimethindeneHumansProspective StudiesSplanchnic CirculationCardiac OutputCimetidineIntraoperative ComplicationsPharmacologybusiness.industrySyndromemedicine.diseaseAbdominal aortic aneurysmSurgeryBlood pressureHistamine H2 AntagonistschemistryAnesthesiaDimetindeneHistamine H1 AntagonistsLaparoscopyAntihistamineHypotensionCimetidinebusinessVascular Surgical ProceduresHistamineAortic Aneurysm AbdominalAbdominal surgerymedicine.drugInflammation Research
researchProduct

Early endovascular aneurysm repair after percutaneous coronary interventions

2015

Objective The objective of this study was to report long-term results of early endovascular aortic aneurysm repair after percutaneous coronary intervention (PCI). Methods This was a retrospective analysis of all patients presenting with abdominal aortic aneurysm and coronary artery disease treated during the same hospitalization by endovascular aortic aneurysm repair performed soon after PCI. Primary outcomes were perioperative mortality, perioperative complications, survival after treatment, and freedom from reintervention. Results A total of 20 patients were included, and all completed both procedures. No deaths or abdominal aortic aneurysm ruptures occurred between the PCI and the aortic…

Malemedicine.medical_treatmentCoronary DiseaseComorbidityEndovascular aneurysm repairSettore MED/22 - Chirurgia VascolareCoronary artery diseaseAortic aneurysmPostoperative ComplicationsRisk FactorsRetrospective StudieCause of DeathMyocardial infarctionHospital MortalityAged; Aged 80 and over; Aortic Aneurysm Abdominal; Cause of Death; Combined Modality Therapy; Comorbidity; Coronary Disease; Follow-Up Studies; Hospital Mortality; Humans; Italy; Male; Middle Aged; Postoperative Complications; Reoperation; Retrospective Studies; Risk Factors; Survival Rate; Early Medical Intervention; Percutaneous Coronary Intervention; Cardiology and Cardiovascular Medicine; Surgery; Medicine (all)Aged 80 and overMedicine (all)Middle AgedCombined Modality TherapyAbdominal aortic aneurysm2746 SurgerySurvival RateItalycardiovascular systemCardiologyCardiology and Cardiovascular MedicineHumanReoperationmedicine.medical_specialty10216 Institute of Anesthesiology610 Medicine & health2705 Cardiology and Cardiovascular MedicineFollow-Up StudiePercutaneous Coronary InterventionInternal medicineEarly Medical InterventionmedicineHumanscardiovascular diseasesRetrospective StudiesAgedbusiness.industryRisk FactorPercutaneous coronary interventionPerioperativemedicine.disease10020 Clinic for Cardiac SurgerySurgeryConventional PCISurgeryPostoperative ComplicationbusinessFollow-Up StudiesAortic Aneurysm Abdominal
researchProduct

Investigation of the hemodynamic flow conditions and blood-induced stresses inside an abdominal aortic aneurysm by means of a SPH numerical model.

2019

The estimation of blood flow-induced loads occurring on the artery wall is affected by uncertainties hidden in the complex interaction of the pulsatile flow, the mechanical parameters of the artery, and the external support conditions. To circumvent these difficulties, a specific tool is developed by combining the aorta displacements measured by an electrocardiogram-gated-computed tomography angiography, with the blood velocity field computed by a smoothed particle hydrodynamics (SPH) numerical model. In the present work, the SPH model has been specifically adapted to the solution of the 3D Navier-Stokes equations inside a domain with boundaries of prescribed motion. Images of the abdominal…

Materials scienceTime FactorsQuantitative Biology::Tissues and OrgansPhysics::Medical PhysicsBiomedical EngineeringPulsatile flowHemodynamicsSettore ICAR/01 - IdraulicaPhysics::Fluid DynamicsAneurysmDiastolemedicine.arterymedicineShear stressPressureHumansComputer SimulationMolecular BiologyAortamedicine.diagnostic_testCardiac cycleApplied MathematicsHemodynamicsModels CardiovascularMechanicsmedicine.diseaseAbdominal aortic aneurysmBiomechanical PhenomenaComputational Theory and MathematicsModeling and SimulationAngiographycardiovascular systemHydrodynamicsStress MechanicalInfrarenal abdominal aorta aneurysm shear stresses arterial wall SPH moving boundarySoftwareAlgorithmsBlood Flow VelocityAortic Aneurysm AbdominalInternational journal for numerical methods in biomedical engineeringREFERENCES
researchProduct

Ergebnisse der kontrastverstärkten MR-Angiographie der aortoiliakalen Gefäße mit einem 1-molaren Kontrastmittel bei 1,0 T: Vergleich zur i. a. DSA

2004

PURPOSE To evaluate the diagnostic accuracy of contrast-enhanced MR angiography (CE-MRA) using a 1.0 molar contrast agent at 1.0 T for the diagnosis of abdominal aortic aneurysms and stenoses of renal or iliac arteries in comparison to intraarterial digital subtraction angiography (DSA). MATERIALS AND METHODS A total of 19 patients with the suspicion of abdominal aortic aneurysm or stenosis of renal or iliac arteries were examined with CE-MRA at 1.0 T. Intra-arterial DSA served as reference in all cases. After test bolus tracking, 10 or 8 ml of the 1.0 molar contrast agent Gadobutrol corresponding to a dose of 0.1 - 0.15 mmol/kg bw were injected and imaging performed using a FLASH-3D sequen…

Molarmedicine.medical_specialtymedicine.diagnostic_testbusiness.industrymedia_common.quotation_subjectDigital subtraction angiographymedicine.diseaseAbdominal aortic aneurysmGadobutrolStenosisText miningOcclusioncardiovascular systemmedicineContrast (vision)Radiology Nuclear Medicine and imagingRadiologybusinessmedicine.drugmedia_commonRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Novel contributions of neutrophils in the pathogenesis of abdominal aortic aneurysm, the role of neutrophil extracellular traps: A systematic review.

2020

Abdominal aortic aneurysm (AAA) is a vascular disorder caused by a dilatation of the aortic diameter that can be potentially lethal in case of rupture. Molecular mechanisms underlying the development of AAA are complex and not completely understood. However, inflammation plays a pivotal role in AAA development. Infiltration of inflammatory cells, especially macrophages, has been widely observed in lesion areas. Nevertheless, neutrophils have been gaining importance in the context of AAA. The release of neutrophil extracellular traps (NETs), extracellular structures formed by DNA, histones, granular and cytoplasmic proteins, is a recently discovered mechanism of neutrophil activation that ca…

Pathologymedicine.medical_specialtyNeutrophilsInflammationmacromolecular substances030204 cardiovascular system & hematologyExtracellular TrapsNeutrophil ActivationLesionPathogenesis03 medical and health sciences0302 clinical medicinemedicineExtracellularHumanscardiovascular diseasesbusiness.industryThrombosisHematologyNeutrophil extracellular trapsmedicine.diseaseAbdominal aortic aneurysm030220 oncology & carcinogenesisVascular Disordercardiovascular systemmedicine.symptombusinessInfiltration (medical)Aortic Aneurysm AbdominalThrombosis research
researchProduct

Improved technique for sheath supported contralateral limb gate cannulation in endovascular abdominal aortic aneurysm repair

2019

Summary: Background: To present a technique of sheath supported contralateral limb gate (CLG) cannulation of modular bifurcated stent-graft in endovascular abdominal aortic repair. Materials and methods: After totally percutaneous bilateral femoral access, the 9F introducer sheath is exchanged to a 30 cm 12 fr introducer sheath over a stiff wire contralateral to the intended main stent-graft insertion side and advanced into the aorta below the lowest renal artery. Parallel to the stiff wire within the sheath an additional standard J-tip guidewire with a 5 fr Pigtail angiographic catheter is advanced to the level of the renal arteries. After main body deployment, the 12 fr introducer sheath…

Pigtailmedicine.medical_specialtyPercutaneouscannulation610 Medicine & healthSettore MED/22 - Chirurgia Vascolare2705 Cardiology and Cardiovascular MedicineBlood Vessel Prosthesis ImplantationRetrospective Studiemedicine.arterygatemedicineStentFluoroscopyHumansEVARREVARRenal arteryRetrospective StudiesAortamedicine.diagnostic_testbusiness.industry10042 Clinic for Diagnostic and Interventional RadiologyEndovascular Proceduresmedicine.diseaseAbdominal aortic aneurysmSurgeryBlood Vessel ProsthesisCatheterBlood Vessel ProsthesiTreatment Outcomecontralateral limbIntroducer sheathStentsCardiology and Cardiovascular MedicinebusinessHumanAortic Aneurysm Abdominal
researchProduct