Search results for "ACOUSTIC"

showing 10 items of 1590 documents

Audiological Investigation of Otitis Media in Children with Atopy

2011

Otitis media (OM) describes an inflammatory process within the middle ear space that is generally associated with accumulation of fluid and that may lead to hearing loss, learning difficulties, and delays in language development. The pathogenesis of OM is multifactorial, involving the adaptive and native immune system, eustachian tube dysfunction, viral and bacterial load, and genetic and environmental factors. The involvement of IgE-mediated allergic reactions in the pathogenesis of OM has been suggested by clinical observations of a high prevalence of OM among patients with allergies. Evidence from studies involving tympanometric measurements, audiometric measurements, and otoscopic exami…

Pulmonary and Respiratory Medicinemedicine.medical_specialtyAllergyHearing lossImmunologyotitis media with effusion (OME)Otoscopymiddle-ear effusionAudiologyPathogenesisAtopyHypersensitivitymedicineHumansImmunology and AllergyChildOtitis mediabusiness.industryOtitis media; middle-ear effusion; acute otitis media (AOM); otitis media with effusion (OME); allergy; Auditory tube dysfunctionAudiologyEustachian tube dysfunctionmedicine.diseaseacute otitis media (AOM)allergySettore MED/32 - AudiologiaAuditory tube dysfunctionMiddle ear effusionmedicine.anatomical_structureOtitisSettore MED/31 - OtorinolaringoiatriaAcoustic Impedance TestsImmunologyMiddle earmedicine.symptombusiness
researchProduct

Measuring Heart Rate with a Heat Flux Sensor

2021

Different wearable biosignal measurement applications require minimally obtrusive and highly sensitive sensors and methods of transducing the heart pulse into an electric signal. At the same time, the sensors should have minimal power consumption and preferably provide information about more than just the heart rate. In this study, a method employing a heat flux sensor for recording the pulsatile cardiac component of an arterial pulse waveform is presented. The output signals of a conventional photoplethysmography (PPG) sensor and a heat flux sensor were recorded and compared with one another. The results show that a heat flux sensor can be used for measurement of heart pulse, in addition t…

Pulse (signal processing)business.industryAcousticsPhotoplethysmogramHeat flux sensorHeart ratePulsatile flowWearable computerWaveformMedicineBiosignalbusiness2021 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)
researchProduct

Focal nodular hyperplasias in normal and fatty liver: a quantitative evaluation with SH U 508A and pulse inversion ultrasound

2003

Pulse inversionPathologymedicine.medical_specialtyAcoustics and UltrasonicsRadiological and Ultrasound Technologybusiness.industryFatty liverUltrasoundBiophysicsmedicineRadiology Nuclear Medicine and imagingbusinessmedicine.diseaseUltrasound in Medicine & Biology
researchProduct

Atypical liver hemangiomas: contrast enhancement patterns with SH U 508A and pulse inversion ultrasound

2003

Pulse inversionmedicine.medical_specialtyContrast enhancementAcoustics and UltrasonicsRadiological and Ultrasound Technologybusiness.industryUltrasoundLiver HemangiomaBiophysicsMedicineRadiology Nuclear Medicine and imagingRadiologybusinessUltrasound in Medicine & Biology
researchProduct

Assessment of a Modified Acoustic Lens for Electromagnetic Shock Wave Lithotripters in a Swine Model

2013

The acoustic lens of the Modularis electromagnetic shock wave lithotripter (Siemens, Malvern, Pennsylvania) was modified to produce a pressure waveform and focal zone more closely resembling that of the original HM3 device (Dornier Medtech, Wessling, Germany). We assessed the newly designed acoustic lens in vivo in an animal model.Stone fragmentation and tissue injury produced by the original and modified lenses of the Modularis lithotripter were evaluated in a swine model under equivalent acoustic pulse energy (about 45 mJ) at 1 Hz pulse repetition frequency. Stone fragmentation was determined by the weight percent of stone fragments less than 2 mm. To assess tissue injury, shock wave trea…

Pulse repetition frequencyShock wavemedicine.medical_specialtySwineUrologySus scrofaMicroscopy AcousticSensitivity and SpecificityArticlelaw.inventionFocal zoneKidney CalculiElectromagnetic FieldsPressure waveformlawLithotripsymedicineAnimalsPulse energyEquipment Safetybusiness.industryEquipment DesignAcoustic lensSurgeryLens (optics)Disease Models AnimalShock wave lithotripterFemalebusinessBiomedical engineering
researchProduct

Comparison of quantitative analysis techniques for the determination of heat seal lacquer layers on aluminum blister foils

2010

For decades a gravimetric method has been common standard for the determination of heat seal lacquers on aluminum blister foils. With the availability of appropriate techniques such as interferometric, infrared reflection absorption spectroscopic (IRRAS), beta backscatter, impedance spectroscopic and eddy current techniques respectively, more efficient determinations can be foreseen which are subject of the present communication. The different methods were compared to each other regarding parameters required for validation of analytical procedures according to the ICH guidelines Q2 (R1) such as linearity, precision, accuracy, robustness and quantitation limits. The interferometric, IRRAS an…

Quality ControlAbsorption (acoustics)Hot TemperatureMaterials scienceSpectrophotometry InfraredBackscatterPharmaceutical Scienceengineering.materiallaw.inventionOpticsCoatinglawEddy currentScattering RadiationElectrical impedanceDrug Packagingbusiness.industryLinearityReference StandardsInterferometryModels ChemicalCalibrationengineeringGravimetric analysisAnalytical proceduresbusinessPlasticsAluminumEuropean Journal of Pharmaceutical Sciences
researchProduct

HIGHLY EXCITED VIBRATIONAL STATES OF CYCLIC MOLECULES INVESTIGATED BY I.C.L.A SPECTROSCOPY WITH PHOTOACOUSTIC DETECTION

1991

The spectra of the fourth and fifth CH stretching overtones of cyclohexene and cyclopentene molecules and of some of their selectively deuterated derivatives have been measured by dye laser intracavity spectroscopy with photoacoustic detection. The intramolecular relaxation of the vibrational energy occurs principally through Fermi resonances with CH2 bending combinations in cyclohexene and through a coupling between the stretching and the ring puckering motions in cyclopentene.

Quantitative Biology::BiomoleculesChemistryExcited state[PHYS.HIST]Physics [physics]/Physics archivesAnalytical chemistryGeneral Physics and AstronomyMoleculePhysical chemistryPhotoacoustic imaging in biomedicinePhysics::OpticsPhysics::Chemical PhysicsSpectroscopy3. Good health
researchProduct

Phonon-induced polariton superlattices

2006

We show that the coherent interaction between microcavity polaritons and externally stimulated acoustic phonons forms a tunable polariton superlattice with a folded energy dispersion determined by the phonon population and wavelength. Under high phonon concentration, the strong confinement of the optical and excitonic polariton components in the phonon potential creates weakly coupled polariton wires with a virtually flat energy dispersion.

Quantum opticsPhysicsCondensed Matter::Quantum GasesQUANTUM MICROCAVITYeducation.field_of_studyCondensed matter physicsPhononCondensed Matter::OtherSuperlatticePopulationEnergy dispersionGeneral Physics and AstronomyPhysics::OpticsAcoustic PhononsEnginyeria acústicaCiència dels materialsCondensed Matter::Mesoscopic Systems and Quantum Hall EffectWavelengthCondensed Matter::Materials SciencePolaritonSURFACE ACOUSTIC-WAVESeducation
researchProduct

Acousto-electric single-photon detector

2007

We propose a novel concept for a semiconductor-based single-photon detector for quantum information processing, which is capable of discriminating the number of photons in a light pulse. The detector exploits the charge transport by a surface acoustic wave (SAW) in order to combine a large photon absorption area (thus providing high photon collection efficiency) with a microscopic charge detection area, where the photo generated charge is detected with resolution at the single electron level using single electron transistors (SETs). We present preliminary results on acoustic transport measured in a prototype for the detector as well as on the fabrication of radio-frequency single-electron t…

Quantum opticsPhysicsPhotonOpticsSemiconductorbusiness.industrySurface acoustic waveDetectorPhotodetectorElectronQuantum informationbusinessSPIE Proceedings
researchProduct

Quenching of bandgaps by flow noise.

2009

We report an experimental study of acoustic effects produced by wind impinging on noise barriers based on two‐dimensional sonic crystals with square symmetry. We found that the attenuation strength of sonic‐crystal‐bandgaps decreases for increasing values of low speed. A quenching of the acoustic bandgap appears at a certain speed value that depends of the barrier filling ratio. For increasing values of low speed, the data indicate that the barrier becomes in a sound source because of its interaction with the wind. We conclude that flow noise has paramount importance in designing acoustic barriers based on sonic crystals. [Work supported by Spanish AECI.]

QuenchingFlow noiseWork (thermodynamics)Materials scienceAcoustics and UltrasonicsArts and Humanities (miscellaneous)Band gapAttenuationAcousticsNoise barrierSymmetry (physics)Square (algebra)The Journal of the Acoustical Society of America
researchProduct