Search results for "ACOUSTIC"
showing 10 items of 1590 documents
Fast ultrasonic phased array inspection of complex geometries delivered through robotic manipulators and high speed data acquisition instrumentation
2016
Performance of modern robotic manipulators has enabled research and development of fast automated non-destructive testing (NDT) systems for complex geometries. This paper presents recent outcomes of work aimed at removing the bottleneck due to data acquisition rates, to fully exploit the scanning speed of modern 6-DoF manipulators. State of the art ultrasonic instrumentation has been integrated into a large robot cell to enable fast data acquisition, high scan resolutions and accurate positional encoding. A fibre optic connection between the ultrasonic instrument and the server computer enables data transfer rates up to 1.6GB/s. Multiple data collection methods are compared. Performance of …
A flexible robotic cell for in-process inspection of multi-pass welds
2020
Welds are currently only inspected after all the passes are complete and after allowing sufficient time for any hydrogen cracking to develop, typically over several days. Any defects introduced between passes are therefore unreported until fully buried, greatly complicating rework and also delaying early corrections to the weld process parameters. In-process inspection can provide early intervention but involves many challenges, including operation at high temperatures with significant gradients affecting acoustic velocities and, hence, beam directions. Reflections from the incomplete parts of the weld would also be flagged as lack-of-fusion defects, requiring the region of interest (ROI) t…
Evaluation of Coded Excitations for Autonomous Airborne Ultrasonic Inspection
2019
Unmanned Aerial Vehicles (UAVs) are receiving increasing attention for use in Non-Destructive Testing due to their ability to access areas where manual inspection is not practical. Contact-based UAV ultrasonic inspections grant the opportunity to remotely monitor the structural health of an industrial asset with enhanced internal integrity information. Ultrasonic inspection is a Non-Destructive Testing (NDT) method conventionally used in corrosion mapping. Surface contacting ultrasonic transducers provide enhanced structural integrity information. However, due to near-surface aerodynamic effects, angular sensitivity of the ultrasound probe and alignment error during autonomous inspections, …
Evaluation of a model of temporal weights in loudness judgments
2018
The onset of a sound receives a higher weight than later portions in time when its loudness is assessed, an effect commonly referred to as primacy effect. It is investigated if this effect can be predicted on the basis of an exponentially decaying function where the weight assigned to a temporal portion of a sound is the integral of this function over the segment duration. To test this model, temporal loudness weights were measured for sounds with different segment durations and total durations. The model successfully predicted essential aspects of the data.
Differential contributions of the two human cerebral hemispheres to action timing
2019
Rhythmic actions benefit from synchronization with external events. Auditory-paced finger tapping studies indicate the two cerebral hemispheres preferentially control different rhythms. It is unclear whether left-lateralized processing of faster rhythms and right-lateralized processing of slower rhythms bases upon hemispheric timing differences that arise in the motor or sensory system or whether asymmetry results from lateralized sensorimotor interactions. We measured fMRI and MEG during symmetric finger tapping, in which fast tapping was defined as auditory-motor synchronization at 2.5 Hz. Slow tapping corresponded to tapping to every fourth auditory beat (0.625 Hz). We demonstrate that t…
Acoustic radiation force impulse point shear wave elastography of the liver and spleen in patients with Gaucher disease type 1: Correlations with cli…
2020
To evaluate the feasibility of acoustic radiation force impulse point shear wave elastography (ARFI-pSWE) of the liver and spleen in patients with Gaucher disease type 1 (GD1), and to assess correlations between organ stiffness and clinico-radiologic data, particularly the GD1 Severity Scoring System (GD-DS3).We retrospectively evaluated the results of ARFI-pSWE as measures of liver and spleen stiffness in 57 patients with GD1. The feasibility of the method was assessed. Correlations between elastography data and clinical data related to the metabolic syndrome, laboratory tests, and GD1-related clinico-radiologic data (bone marrow burden score, GD-DS3) were assessed.ARFI-pSWE provided relia…
Hearing Without Neuroglobin.
2017
Abstract Neuroglobin (Ngb) is a member of the globin family of respiratory proteins, which was recently observed in many neurons of the auditory pathways. Up to now, however, nothing was known about the role of Ngb in hearing processes. We therefore studied auditory function by recording distortion-product otoacoustic emissions (DPOAE) and auditory brainstem responses (ABRs) in wild-type (C57BL/6N) and Ngb-knockout mice. In KO mice, DPOAE thresholds were moderately augmented in the range of 5–18 kHz, reaching statistical significance at 8 and 10 kHz, while the ABR thresholds were not different between groups. The activation of the efferent system by an additional noise given to the contrala…
Effect of counting chamber depth on the accuracy of lensless microscopy for the assessment of boar sperm motility.
2017
Sperm motility is one of the most significant parameters in the prediction of male fertility. Until now, both motility analysis using an optical microscope and computer-aided sperm analysis (CASA-Mot) entailed the use of counting chambers with a depth to 20 µm. Chamber depth significantly affects the intrinsic sperm movement, leading to an artificial motility pattern. For the first time, laser microscopy offers the possibility of avoiding this interference with sperm movement. The aims of the present study were to determine the different motility patterns observed in chambers with depths of 10, 20 and 100 µm using a new holographic approach and to compare the results obtained in the 20-µm c…
The effect of silent gaps on temporal weights in loudness judgments
2020
Abstract Human loudness judgments of time-varying sounds show a non-uniform temporal weighting pattern with increased weights at the beginning of a sound. Four experiments were conducted to investigate whether this primacy effect reoccurs after a silent gap of an appropriate duration that is inserted into a level-fluctuating sound. In three of the experiments, contiguous sounds as well as sounds containing silent gaps of different durations were presented. The temporal loudness weights were compared between the sounds that contained a gap and the sounds without a gap. The data showed that with increasing gap duration an increasingly pronounced primacy effect reoccurred on the second sound p…
Damage detection of a hybrid composite laminate aluminum/glass under quasi-static and fatigue loadings by acoustic emission technique
2019
Abstract This paper deals with the characterization by Acoustic Emission technique of damages occurring in a hybrid laminate aluminium/glass during quasi-static and fatigue tests. Indeed, hybrid laminates materials metal/composites are more and more considered in structure, automotive and aerospace designs because of their good mechanical performances and lightness. To understand their damages characteristics, several types of laminates (fiber orientations, number of folds, presence or not of an aluminium sheet) have been tested. The acoustic emission analysis has been realized using statistical multi-parameters methods of data clustering: combination of Principal Components Analysis (PCA) …