Search results for "AML"
showing 10 items of 184 documents
Status report of the Jyvaskyla ion guide isotope separator on-line facility
1997
The ion guide isotope separator facility IGISOL of the University of Jyvaskyla has been moved to the new K-130 heavy ion cyclotron laboratory. The totally reconstructed facility is described in detail. The primary beams and targets, helium pumping, separator beam line construction and separator beam diagnostics are discussed. The spectroscopy stations are introduced with illustrative examples from the research program, including beta-delayed proton and neutron spectroscopy, gamma-ray spectroscopy with and without arrays, conversion electron spectroscopy, collinear laser spectroscopy and nuclear level lifetime spectroscopy.
Fast and compact data acquisition for gas-filled detectors with delay line
2004
This article describes the functionality, implementation and performance of a PCI data acquisition board that can be used in conjunction with gas-filled detectors with delay line readout. The board combines a large on-board 256-MByte histogramming memory with a maximum 10-MHz count rate in continuous operation and integrates the time frame generation, histogram building and buffering functionalities in a single PCI board, resulting in a fast, compact and cost-effective data acquisition solution for the Spanish beamline BM16 at ESRF.
Measurement of high energy resolution inelastic proton scattering at and close to zero degrees
2009
13 pages, 15 figures.-- Printed version published Jul 1, 2009.
Laser photodetachment of radioactive $^{128}$I$^−$
2017
International audience; The first experimental investigation of the electron affinity (EA) of a radioactive isotope has been conducted at the CERN-ISOLDE radioactive ion beam facility. The EA of the radioactive iodine isotope (128)I (t (1/2) = 25 min) was determined to be 3.059 052(38) eV. The experiment was conducted using the newly developed Gothenburg ANion Detector for Affinity measurements by Laser PHotodetachment (GANDALPH) apparatus, connected to a CERN-ISOLDE experimental beamline. (128)I was produced in fission induced by 1.4 GeV protons striking a thorium/tantalum foil target and then extracted as singly charged negative ions at a beam energy of 20 keV. Laser photodetachment of th…
Upgrades to the collinear laser spectroscopy experiment at the IGISOL
2020
Abstract We give an overview of recent changes to the collinear laser spectroscopy beamline in the IGISOL laboratory. We present a new data acquisition system, commissioning of a newly installed charge exchange cell, and cooler-voltage calibration measurements. Currently ongoing modifications to the RFQ cooler-buncher are also discussed.
A new beamline for energy-dispersive high-resolution PIXE analysis using polycapillary optics
2019
Abstract A new beamline for high energy resolution PIXE measurements is presented. This new setup includes options for both in-air and vacuum measurements. For the high energy resolution transition-edge sensor array, a polycapillary lens is used for detecting low-energy X-rays down to 0.5 keV and to increase the effective solid angle. X-ray transmission of the polycapillary lens was characterized using two calibration standards. The gain obtained by adding a polycapillary lens was 1.6–2.3 at energies between 2.1 keV and 4.5 keV. From 1.04 to 1.74 keV the gain is increased to 2.1–3.0, and at energies 4.9–8.0 keV the gain is between 1.6 and 0.65. The measured gain agreed well with theoretical…
Luminescence spectroscopy under synchrotron radiation: From SUPERLUMI to FINESTLUMI
2020
Abstract Luminescence spectroscopy under synchrotron radiation excitation is the unique tool for materials characterization. In the current work we are reporting recent activity in this research field implemented in the Finnish-Estonian beamline (FinEstBeAMS) which is installed at the 1.5 GeV storage ring of the MAX IV Laboratory at Lund, Sweden. It has been designed to cover an unusually wide energy range from ultraviolet (4.3 eV) to soft X-rays (1500 eV), which is perfectly suited for luminescence spectroscopy experiments. The past development and the present technical parameters of the luminescence experimental stations FINESTLUMI of FinEstBeAMS beamline are described. The comparison of …
Technical design of the phase I Mu3e experiment
2021
Nuclear instruments & methods in physics research / A 1014, 165679 (2021). doi:10.1016/j.nima.2021.165679
Prediction of neutrino fluxes in the NOMAD experiment
2003
The method developed for the calculation of the flux and composition of the West Area Neutrino Beam used by NOMAD in its search for neutrino oscillations is described. The calculation is based on particle production rates computed using a recent version of FLUKA and modified to take into account the cross sections measured by the SPY and NA20 experiments. These particles are propagated through the beam line taking into account the material and magnetic fields they traverse. The neutrinos produced through their decays are tracked to the NOMAD detector. The fluxes of the four neutrino flavours at NOMAD are predicted with an uncertainty of about 8% for nu(mu) and nu(e), 10% for antinu(mu), and…
Performance and characterization of the FinEstBeAMS beamline at the MAX IV Laboratory
2021
European Regional Development Fund (grant No. TK-141 HiTechDevices 2014-2020.4.01.15-0011 to University of Tartu; grant No. MAX-TEENUS 2014-2020.4.01.20-0278 to University of Tartu; grant No. Eesti Kiirekanal SLOFY11156T/1 to University of Tartu); Estonian Research Council (grant No. PRG-629 to University of Tartu); Jane & Aatos Erkko Foundation (grant No. SOFUS); Business Finland (grant No. 1464/31/2019); Academy of Finland (grant No. 319042; grant No. 326461; grant No. 326406; grant No. 320165); University of Oulu; University of Turku; Tampere University; University of Tartu.