Search results for "AOC"
showing 10 items of 504 documents
Flicker Defined Form Perimetry in Glaucoma Suspects with Normal Achromatic Visual Fields
2014
To evaluate if repeated flicker-defined form (FDF) perimetry can detect visual field (VF) defects in glaucoma suspects with normal findings in achromatic standard automated perimetry (SAP).Patients with optic nerve heads (ONHs) or retinal nerve fiber layer (RNFL) findings clinically suspicious for glaucoma and normal SAP were enrolled. Patients underwent VF testing with FDF perimetry (Heidelberg Edge Perimetry, HEP) at two consecutive visits (HEP I and HEP II) and confocal scanning laser ophthalmoscopy with the Heidelberg Retina Tomograph (HRT). Abnormal HEP was defined by cluster-point analysis (CPA) and by the HEP specific glaucoma hemi-field test (GHT). Results were compared with an age-…
Quality of vision with the Acri. Twin asymmetric diffractive bifocal intraocular lens system.
2007
To assess the quality of vision in patients who had implantation of asymmetric Acri. Twin bifocal diffractive intraocular lenses (IOLs) by evaluating distance and near visual acuities and photopic and mesopic contrast sensitivity under monocular and binocular conditions.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.The study comprised 343 consecutive patients who had bilateral implantation of the Acri. Twin system: a distance-weighted 737D IOL and a near-weighted 733D IOL. Monocular and binocular best corrected distance visual acuities, best distance corrected near visual acuity, and distance contrast sensitivity under photopic (85 cd/m(2)) and mesopic (5 cd/m(2)) conditions were…
Visual function after implantation of a diffractive aspheric trifocal intraocular lens
2016
Purpose To evaluate distance, intermediate, and near vision after bilateral implantation of a diffractive aspheric trifocal intraocular lens (IOL). Methods This study enrolled 204 eyes of 102 patients who had bilateral implantation of the AT LISA tri 839MP IOL. Monocular and binocular uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) (4 meters), monocular and binocular uncorrected near visual acuity (UNVA) and distance-corrected near visual acuity (DCNVA) (30, 40 centimeters), binocular uncorrected intermediate visual acuity (UIVA) and distance-corrected intermediate visual acuity (DCIVA) (50, 60, 70 centimeters), the defocus curve, and binocular photopic…
Multichannel functional testing in normal subjects, glaucoma suspects, and glaucoma patients
2012
Purpose.: To evaluate visual function with a novel multichannel functional test named the ATD Multichannel Functional Test. Methods.: This multicenter study had a prospective and cross-sectional design. A total of 186 eyes were included: 42 with glaucoma, 14 glaucoma suspects due to optic nerve characteristics, 25 ocular hypertensives, and 105 normal eyes. All patients performed standard visual fields (Humphrey 24-2) and ATD with eight stimuli configurations: four achromatic (A), two red-green (T), and two blue-yellow (D). To derive main outcome measures, mean sensitivity, mean defect (MD), and pattern standard deviation (PSD) were calculated and compared among groups and types of stimuli w…
Optical quality in eyes with aspheric intraocular lenses and in younger and older adult phakic eyes: comparative study.
2009
To compare ocular higher-order aberrations (HOAs) in eyes with aspheric intraocular lenses (IOL) and in phakic eyes.Department of Ophthalmology, Military Health Service Institute, Warsaw, Poland.Higher-order aberrations with a 5.0 mm pupil and best spectacle-corrected visual acuity (BSCVA) were analyzed in a young phakic group (age 20 to 40 years), older phakic group (age 40 to 60 years), and a pseudophakic group (age 62 to 84 years; SN60WF aspheric IOL).The mean coma was 0.13 microm+/-0.07 (SD) in the younger phakic group, 0.18+/-0.08 microm in the older phakic group, and 0.16+/-0.08 microm in the pseudophakic group; the difference between the 2 phakic groups was statistically significant …
Comparison of visual and refractive results of Toric Implantable Collamer Lens with bioptics for myopic astigmatism.
2013
PURPOSE: To compare visual and refractive results of Toric Implantable Collamer Lens (TICL) and bioptics (ICL plus excimer corneal surgery) to treat myopic astigmatism. METHODS: Eighty-one eyes underwent TICL implantation and 83 eyes were treated with bioptics (corneal ablation was performed between 1.5 and 6 months after ICL implantation). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refraction, adverse events, safety, and efficacy were evaluated 12 months postoperatively. RESULTS: At 12 months postoperatively, the mean spherical equivalent was -0.15 ± 0.36 diopters (D) in the TICL group and -0.08 ± 0.26 D in the bioptics group (p = 0.099). Sixty-six …
Sutureless ciliary sulcus supported intraocular lens with transiridal anchoring haptics.
2003
We report a technique for implanting intraocular lenses (IOLs) in the ciliary sulcus in eyes without capsule support. The IOL design allows it to be implanted without fixation sutures. The lens was implanted in 3 aphakic eyes without capsule support.
Scheimpflug biometry of the anterior segment after implantation of foldable iris-fixated lenses.
2006
ABSTRACT PURPOSE: To evaluate intraocular dimensions of the anterior segment of myopic phakic eyes after implantation of foldable iris-fixated lenses. METHODS: Seventeen myopic eyes that received a foldable iris-fixated phakic intraocular lens (PIOL) were assessed. Distances between the cornea and the IOLoptic edge and between the IOL optic and the crystalline lens were evaluated using Scheimpf lug photography 3 months postoperatively. RESULTS: The average postoperative distance between the central corneal endothelium and the anterior surface of the IOL was 2.01±0.26 mm. The distance between the corneal endothelium and the peripheral edge of the IOL averaged 1.32±0.18 mm at the 12 o'clock p…
Effects of intraocular cefotaxime on the human corneal endothelium
2001
Abstract Purpose To ascertain whether 0.4 mL of cefotaxime 0.25% applied intracamerally causes toxic alteration of the human corneal endothelium. Methods In this prospective randomized masked study, 66 patients had cataract extraction using phacoemulsification, a frown incision, and implantation of a poly(methyl methacrylate) intraocular lens. This was followed by intraocular injection of 0.4 mL of cefotaxime 0.25% or balanced salt solution (BSS®). Contact specular microscopy and photography were performed preoperatively and 1 to 4 days and 3 months postoperatively. Results In the cefotaxime group, the mean endothelial cell count was 2729 cells/mm 2 ± 474 (SD) preoperatively, 2520 ± 462 cel…
Graves ophthalmopathy: role of MR imaging in radiation therapy.
1991
Twenty-three patients with Graves ophthalmopathy who underwent radiation therapy were monitored by means of magnetic resonance (MR) imaging. T2 relaxation times of extraocular muscles and orbital fat, areas of extraocular muscles, and degree of exophthalmos were measured by means of MR imaging at the beginning, at the end, and 3 months after completion of radiation therapy. As a result, patients with primarily elevated T2 times of extraocular muscles showed a better therapy response regarding muscle thickening than patients with primarily normal T2 times. Elevated T2 times, which probably represent acute inflammatory changes, were markedly decreased at the end of therapy. Therefore, quantit…