Behaviour of the phakic iris-claw intraocular lens (Artisan /Verisyse) during accommodation: an optical coherence biometry study.

2007

Purpose To evaluate variations in the position of the phakic iris claw lens (Artisan®, Verisyse®) and the natural crystalline lens during the accommodation process. Methods We measured changes in position of the iris claw lens and the crystalline lens during the accommodation using optical coherence biometry (AC Master®/Carl Zeiss Meditec, Germany) in 17 patients (28 eyes) with a phakic iris claw lens implanted for high myopia and/or myopic astigmatism. Accommodative effort was obtained using an internal optical target within the measuring device. Results There was a forward shift of the phakic iris claw lens with a mean of 70 μm (8–178 μm) of the optical path length (OPL). At the same time…

Adultmedicine.medical_specialtyPhakic Intraocular LensesMaterials scienceBiometrymedicine.medical_treatmentIrisIntraocular lensRefraction OcularMyopic astigmatism03 medical and health sciences0302 clinical medicineOpticsLens Implantation IntraocularAnterior Eye SegmentOphthalmologyLens CrystallinemedicineMyopiaHumansIris clawOptical path lengthbusiness.industryHigh myopiaAccommodation OcularAstigmatismGeneral MedicineMiddle AgedOphthalmologymedicine.anatomical_structureLens (anatomy)030221 ophthalmology & optometrybusinessAccommodation030217 neurology & neurosurgeryTomography Optical CoherenceCoherence (physics)Follow-Up StudiesEuropean journal of ophthalmology
researchProduct

Learning Curve and Fatigue Effect of Flicker Defined Form Perimetry

2011

To evaluate the learning curve and fatigue effect of flicker defined form (FDF) perimetry.Prospective cross-sectional study.One hundred forty-one eyes of 75 healthy subjects were included in the study. Every subject was measured 3 times on 3 different days within 3 months. Differences among the tests were analyzed for mean sensitivity (MS), mean deviation (MD), pattern standard deviation (PSD), reliability indices, test duration, and test points5% and0.5% in 75 right eyes on the basis of linear mixed models for repeated measurements. To assess the effect of fatigue, differences of MS, MD, and PSD values between 66 left and right eyes were evaluated regarding alterations between these 3 exam…

Adultmedicine.medical_specialtyVisual AcuitySignificant learningSensitivity and SpecificityPattern standard deviationOphthalmologymedicineHumansProspective StudiesIntraocular PressureAgedbusiness.industryFlickerHealthy subjectsGlaucomaMiddle AgedTest durationAbsolute deviationOphthalmologyCross-Sectional StudiesVisual Field TestsAsthenopiaVisual FieldsbusinessLearning CurveAmerican Journal of Ophthalmology
researchProduct

Capsular bag shrinkage after implantation of a capsular bending or capsular tension ring.

2005

To evaluate the influence of a capsular bending ring (CBR) or tension ring (CTR) on capsular bag shrinkage.Department of Ophthalmology, Johannes Gutenberg-University, and Department of Medical Biometry, Epidemiology and Informatics, University of Mainz, Mainz, Germany.In 92 eyes of 92 patients, a capsular measuring ring (CMR) was implanted after phacoemulsification to measure capsular bag size in vivo. Patients were randomized into 3 groups: The first received a CMR and CBR, the second received a CMR and CTR, and the third received a CMR alone. Measurements were performed preoperatively, intraoperatively, during the first 3 postoperative days, and after 1 and 3 months. Preoperative biometri…

Adultmedicine.medical_specialtyVisual acuityBiometrymedicine.medical_treatmentLens Capsule CrystallineCapsular tension ringIntraocular lensCataract ExtractionGroup differencesLens Implantation IntraocularOphthalmologymedicineHumansCapsulorhexisShrinkageAgedAged 80 and overPhacoemulsificationbusiness.industryPhacoemulsificationEquipment DesignProstheses and ImplantsMiddle AgedSensory SystemsSurgeryOphthalmologyCapsular bagMicroscopy Electron ScanningSurgerymedicine.symptombusinessJournal of cataract and refractive surgery
researchProduct

Contrast sensitivity after implantation of toric iris-claw lenses in phakic eyes.

2004

Abstract Purpose: To evaluate the change in contrast sensitivity after implantation of the Verisyse toric phakic intraocular lens (IOL) (AMO) for the correction of myopia with astigmatism. Setting: Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods: Eighteen eyes had implantation of an iris-supported toric phakic IOL to correct myopia with astigmatism. The mean preoperative spherical equivalent was −12.65 diopters ± 3.6 (SD). The contrast sensitivity with best spectacle correction was determined before surgery and 3 months after surgery using the CSV-1000 HGT instrument (Vector Vision Inc.). Results: Three months after IOL implantation, the mean contrast sen…

Adultmedicine.medical_specialtygenetic structuresmedia_common.quotation_subjectAstigmatismPhakic intraocular lensProsthesis DesignCycles per degreelaw.inventionContrast SensitivityLens Implantation IntraocularlawOphthalmologyLens CrystallinemedicineMyopiaContrast (vision)HumansPhakic iolIris clawDioptremedia_commonLenses Intraocularbusiness.industryAstigmatismMiddle Agedmedicine.diseaseeye diseasesSensory SystemsLens (optics)OphthalmologySurgerysense organsbusinessJournal of cataract and refractive surgery
researchProduct

Ipotesi di ricostruzione virtuale della piazza maggiore a Noto Antica

2019

Today ancient Noto is a medieval archaeological site, yet to be discovered. After the 1693 earthquake, the ancient city of Noto, in the middle of the Baroque period, was rebuilt in another place and the ancient city was abandoned. The first excavation campaign in ancient Noto by Paolo Orsi dates back to the period between 1894 and 1896. In the following years there will be other excavation campaigns, in which other architectural and sculptural relics will be found. They are today part of the collection of the Civic Museum. The contribution focuses on the study of the piazza Maggiore (Main Square) site, the center of the ancient city and on the surrounding buildings. After analyzing the limi…

Ancient Noto Virtual Reconstruction Mother Church of San Nicolò Fountain of the Laocoon Town HallSettore ICAR/19 - Restauro
researchProduct

Accommodative intraocular lenses: current status

2005

Purpose of review The possibility of using a monofocal IOL with accommodative ability allows refractive cataract surgery with a clearly decreased potential of photic phenomena. Three IOLs of different designs and materials have demonstrated accommodative ability, but the degree of accommodative amplitude has been reported to different extents and variabilities. The plate-haptic CrystaLens has a hinged design that might permit forward movement of the optic as a result of pressure changes in the vitreous cavity. The 1CU has modified haptics that bend in the bag as the lens capsule contracts, which are supposed to cause anterior displacement of the lens optic. With the dual-optic one-piece Syn…

Anterior lensgenetic structuresmedicine.medical_treatmentCataract ExtractionProsthesis Designlaw.inventionLens Implantation IntraocularlawmedicineHumansLenses IntraocularLens capsulebusiness.industryAccommodation OcularPresbyopiaGeneral MedicinePresbyopiaCataract surgerymedicine.diseaseeye diseasesLens (optics)OphthalmologyIntraocular lensesCapsular bagOptometrysense organsbusinessAccommodationCurrent Opinion in Ophthalmology
researchProduct

Comparison of two different devices to assess intraocular lenses

2016

[EN] In this paper, we have compared the performance of two commercial systems, Kaleo-I and IOLA Plus, in the characterization of monofocal intraocular lenses (IOLs) according to the International Standard requirements (ISO 11979-2). The dioptric power (DP) and the Modulation Transfer Function (MTF) at 100.1p/mm and 3.0 mm aperture have been measured with both instruments in twenty commercial monofocal HEMA IOLs and their agreement was assessed by Bland Altman analysis. Compared with the designed power, IOLA Plus gave lower values in 85% of measures: Kaleo I errors are dependent on the power of the lens: measurements were higher than the designed power in the low-medium power range and lowe…

Aperture01 natural scienceslaw.invention010309 optics03 medical and health sciencesMonofocal intraocular lens0302 clinical medicineOpticslawOptical transfer function0103 physical sciencesElectrical and Electronic EngineeringBland–Altman plotInternational standard and reliabilityMathematicsDioptric powerbusiness.industryModulation transfer functionAtomic and Molecular Physics and OpticsConfidence intervalElectronic Optical and Magnetic MaterialsLens (optics)Intraocular lensesFISICA APLICADA030221 ophthalmology & optometrybusiness
researchProduct

Approche historique du processus de délimitation des AOC vinicoles françaises. Contribution à la compréhension des principes et de l’application d’un…

2010

National audience

Appellation d'origine contrôléeViticulture[ SHS ] Humanities and Social SciencesAOC[SHS] Humanities and Social SciencesComputingMilieux_MISCELLANEOUS[SHS]Humanities and Social Sciences
researchProduct

Central corneal thickness in mucopolysaccharidosis II and VI.

2010

Objective To describe the ultrasonographically detected central corneal thickness (CCT) in patients with Type II and VI mucopolysaccharidosis (MPS) and its impact on applanation tonometry and glaucoma detection. Methods Twenty-eight patients with MPS (19 MPS II, nine MPS VI) underwent pachymetric investigation of CCT. Additionally, ultrasound measurements of axial length of the globe, slit-lamp evaluation with semiquantitative grading of corneal clouding, applanation tonometry, and assessment of refractive error were performed. Results Median average corneal thickness was 534.5 microm (range, 491.5-579.0 microm) in the MPS II and 547.0 microm (range, 492.5-693.05 microm) in the MPS VI group…

Applanation tonometryAdultMalecongenital hereditary and neonatal diseases and abnormalitiesRefractive errorIntraocular pressuremedicine.medical_specialtygenetic structuresAdolescentMucopolysaccharidosis IIMucopolysaccharidosisGlaucomaCorneal DiseasesCorneaTonometry OcularOphthalmologymedicineHumansIn patientProspective StudiesChildIntraocular PressureMucopolysaccharidosis IIUltrasonographyMucopolysaccharidosis VIAnthropometrybusiness.industryUltrasoundnutritional and metabolic diseasesGlaucomaMiddle Agedmedicine.diseaseeye diseasesOphthalmologyFemalesense organsbusinessCornea
researchProduct

A comparison of the Canon TX-20P™ non-contact tonometer and pachymeter in healthy eyes

2012

Background: The aim of this study was to compare the intraocular pressure (IOP) and the central corneal thickness (CCT) measurements obtained with the Canon TX-20P™ with IOP measured with Goldmann applanation tonometer (GAT) and the CCT measured with ultrasound (US) pachymetry in healthy eyes. Methods: Thirty one healthy voluntary subjects participated in the study, age ranging from 16 to 81 years (mean age 50.9 years). In total 58 eyes were selected for analysis. All measurements were performed by the same examiner. The measurements were taken in the same order in all subjects: Canon IOP and CCT, Goldmann IOP and US CCT. Results: A strong correlation was found between IOP for both CCT comp…

Applanation tonometryIntraocular pressuremedicine.medical_specialtygenetic structuresbusiness.industrySignificant differenceGoldmann Applanation TonometerMean ageNon contact tonometereye diseasesOphthalmologyMedicineOptometrysense organsbusinessInternational Journal of Ophthalmic Practice
researchProduct