Search results for "AOC"
showing 10 items of 504 documents
Anaesthetic protocol for paediatric glaucoma examinations: the prospective EyeBIS Study protocol
2021
IntroductionNeonates and young infants with diagnosed or highly suspected glaucoma require an examination under anaesthesia to achieve accurate intraocular pressure (IOP) measurements, since crying or squinting of the eyes may increase IOP and lead to falsely high values. IOP considerably depends on perioperative variables such as haemodynamic factors, anaesthetics, depth of anaesthesia and airway management. The aim of this paper is to report the design and baseline characteristics of EyeBIS, which is a study to develop a standardised anaesthetic protocol for the measurement of IOP under anaesthesia in childhood glaucoma, by investigating the link between the magnitude of IOP and depth of …
Learning from the past: Mitomycin C use in trabeculectomy and its application in bleb-forming minimally invasive glaucoma surgery.
2019
Trabeculectomy has been performed since the mid-1960s and remains the gold standard for glaucoma surgery. Newer surgical options have evolved, collectively referred to as minimally invasive glaucoma surgeries. Despite producing large intraocular pressure decreases, full-thickness procedures into the subconjunctival space may be limited by fibrosis. Mitomycin C (MMC) and 5-fluorouracil have been in use with trabeculectomy with good evidence of significantly increased success at the cost, however, of an increased risk of complications. Off-label MMC application can be found in almost all clinical trials, including in combination with minimally invasive glaucoma surgeries. We explore current e…
2020
Objective To compare surgical success, postoperative intraocular pressure and complication rates between trabeculectomy and XEN gelstent surgery in a cohort of glaucoma patients in a typical clinical setting. Methods A retrospective cohort study of consecutive patients with refractory open-angle glaucoma including patients who underwent either stand-alone XEN gelstent insertion with Mitomycin C or trabeculectomy with Mitomycin C between 2016 and 2018 at the University Eye Hospital Mainz, Germany. Primary outcome measure was the proportion of surgical success 1 year after surgery. Patients with an IOP ≤18mmHg, an intraocular pressure reduction of >20% and in no need of revision surgery or to…
2015
Aims To investigate the feasibility and to compare three devices measuring intraocular pressure (IOP) in mucopolysaccharidosis patients (MPS): iCare rebound tonometer (RT), Perkins applanation tonometer (PAT) and ocular response analyzer (ORA)
Distribution of Intraocular Pressure and Its Association with Ocular Features and Cardiovascular Risk Factors
2013
Purpose To describe the distribution of intraocular pressure (IOP) and its association with ocular features and cardiovascular risk factors in an adult European cohort. Design Population-based, cross-sectional study. Participants This analysis was based on a Gutenberg Health Study (GHS) cohort that included 4335 eligible enrollees from among 5000 subjects who participated in the survey from 2007 through 2008. The age range was 35 to 74 years at enrollment. Methods Participants underwent a standardized protocol with a comprehensive questionnaire; ophthalmic examination including slit-lamp biomicroscopy, noncontact tonometry, fundus photography, central corneal thickness measurement, and visu…
Do Age and Sex Play a Role in the Intraocular Pressure Changes after Acrobatic Gymnastics?
2021
To evaluate the effects of an acrobatic gymnastics (AG) training session on intraocular pressure (IOP), a familiarization session was employed to confirm the participant’s suitability for the study. Forty-nine gymnasts (63.27% females, 18–40 years old) voluntarily agreed to participate. As age, sex, baseline IOP, and central corneal thickness (CCT) were considered as potential predictors of the IOP variations, in the second session measurements of the above parameters were taken before and after 90 min of AG. A mixed-factorial analysis of variance evaluated differences. Linear regression was conducted to potentially predict the IOP variation with the exercise. After the scheduled exercise, …
Safety and performance of a suprachoroidal sensor for telemetric measurement of intraocular pressure in the EYEMATE-SC trial
2023
AimTo investigate the safety and performance of a telemetric suprachoroidal intraocular pressure (IOP) sensor (EYEMATE-SC) and the accuracy of its IOP measurements in open angle glaucoma (OAG) patients undergoing simultaneous non-penetrating glaucoma surgery (NPGS).MethodsProspective, multicentre, open-label, single-arm, interventional clinical trial. Twenty-four eyes of 24 patients with OAG regularly scheduled for NPGS (canaloplasty or deep sclerectomy) were simultaneously implanted with an EYEMATE-SC sensor. Six-month follow-up on the sensor’s safety and performance as well as on the level of agreement between the EYEMATE-SC measurements and IOP measurements with Goldmann applanation tono…
Large diurnal variation of intraocular pressure in open angle glaucoma in subjects with type A behaviour pattern
2014
Aim : To evaluate the possible causes of the greater perimetric damage found in OAG subjects with type A behaviour and the possible role of psycho-physiological stress. Materials and methods : 80 patients with OAG, 44 women and 36 men, 40 with type A behaviour and 40 with type B studied with the Type A/B Personality Questionnaire (A modified version of the Jenkins Activity Survey), underwent a complete ophthalmologic examination consisting of bio-microscopy, tonometry and daily tonometric curve, examination of the visual field by means of Octopus 1-2-3 computerised perimeter and its assessment with the Glaucoma Staging System 2 (GSS2), morphological monitoring of the Retinal Nerve Fibre Lay…
Intercurrent factors associated with the development of open-angle glaucoma in The European Glaucoma Prevention Study
2007
Purpose: To evaluate the intercurrent factors for the development of open-angle glaucoma (OAG) in ocular hypertensive patients who were enrolled in the European Glaucoma Prevention Study (EGPS). Design: Randomized, double masked, controlled clinical trial. Methods: setting: Multicenter. study population: A total of 1,077 patients fulfilled a series of inclusion criteria, including intraocular pressure (IOP) 22 to 29 mm Hg, normal and reliable visual fields (VFs) and normal optic disks. intervention: Treatment with dorzolamide or placebo. main outcome measures: Glaucoma-related VF or optic disk changes. Clinical data were collected every six months during a five-year follow-up. Proportional …
Comparison of subconjunctival microinvasive glaucoma surgery and trabeculectomy
2021
Purpose To assess surgical success and the post-operative development of intraocular pressure between XEN45® gelstent, Preserflo® MicroShunt and trabeculectomy with mitomycin C. Methods Data from 105 eyes from 105 patients of matched cases with refractory open-angle glaucoma, who underwent surgery between January 2019, and August 2020, were evaluated. Patients underwent either stand-alone XEN gelstent insertion with Mitomycin C, stand-alone Preserflo with Mitomycin C or trabeculectomy with Mitomycin C. The primary outcome was the proportion of complete surgical success at 6 months post-operatively (i.e. intraocular pressure between 5mmHg and 18mmHg, no revision surgery, no loss of light per…