Corneal thickness in children with growth hormone deficiency: The effect of GH treatment.

2014

Abstract OBJECTIVE: The eye represents a target site for GH action, although few data are available in patients with GH deficiency (GHD). Our aim was to evaluate central corneal thickness (CCT) and intraocular pressure (IOP) values in GHD children to assess the role played by GHD or GH treatment on these parameters. DESIGN: In 74 prepubertal GHD children (51M, 23F, aged 10.4±2.4years) we measured CCT and IOP before and after 12months of treatment. A baseline evaluation was also made in 50 healthy children matched for age, gender and body mass index. The study outcome considered CCT and IOP during treatment and their correlations with biochemical and auxological data. RESULTS: No difference …

Malegrowth hormone deficiencymedicine.medical_specialtyIntraocular pressurePediatricsgenetic structuresEndocrinology Diabetes and MetabolismGrowth hormone deficiencySettore MED/13 - EndocrinologiaCorneaEndocrinologyGH treatmentInternal medicineHumansMedicineIn patientCorneal thickneChildDwarfism PituitaryIntraocular PressureBaseline valuesHuman Growth Hormonegrowth hormone deficiency; Corneal thickness; GH treatmentbusiness.industryOrgan Sizemedicine.diseaseeye diseasesEndocrinologyTarget siteGh treatmentFemalesense organsbusinessBody mass indexGH Deficiency
researchProduct

The Effect of Anesthetic Eye Drop Instillation on the Distribution of Corneal Thickness

2012

PURPOSE To address the effect of topical instillation of oxybuprocaine on the relative distribution of corneal thickness (CT) in young healthy subjects. METHODS Prospective study involving 30 eyes of 30 emmetropic subjects (24 ± 3 years). Corneal thickness measurements were carried out before and 3 minutes after the instillation of oxybuprocaine 4% using slit-scanning corneal topography (Orbscan topography system II). No acoustic correction factor was applied. The mean of 5 consecutive Orbscan measurements was obtained at the center and 3 mm from the visual axis in the temporal, superior, nasal, and inferior hemimeridians. RESULTS No significant mean differences were found at any corneal lo…

Malemedicine.medical_specialtyAdministration Topicalmedicine.medical_treatmentEmmetropiaTopical anestheticCorneaTonometry OcularYoung AdultOphthalmologyCorneamedicineHumansDistribution (pharmacology)Prospective StudiesAnesthetics LocalOxybuprocaineIntraocular Pressuremedicine.diagnostic_testbusiness.industryCorneal TopographyEye dropEmmetropiaCorneal topographyeye diseasesOphthalmologymedicine.anatomical_structureAnesthesiaAnestheticFemalesense organsOphthalmic SolutionsbusinessProcainemedicine.drugCornea
researchProduct

Series of fibrinous inflammation after implantation of capsular tension rings

2014

Purpose To analyze the cause of fibrinous inflammation in eyes with capsular tension rings (CTRs) after cataract surgery. Setting Department of Ophthalmology, University Medical Center, Johannes Gutenberg-University Mainz, Mainz, Germany. Design Retrospective case series. Methods High-performance liquid chromatography was implemented to eliminate impurities. One CTR was explanted for microbiologic examination. The pH values of the CTR and the storage solution were analyzed, Seldi and Maldi tests were performed, as well as toxicity tests with immortal cell lines. Material batches were analyzed. The organic carbon content of CTRs, detergents, and storage solutions was checked. The presence of…

Malemedicine.medical_specialtyAfter cataractTopical treatmentMethylmethacrylatemedicine.disease_causeProsthesis ImplantationPostoperative ComplicationsLens Implantation IntraocularOphthalmologymedicineHumansUniversity medicalDevice RemovalAgedRetrospective StudiesAged 80 and overEndophthalmitisFibrinPhacoemulsificationAmoebocyte lysatebusiness.industrySmear testsFibrinous inflammationProstheses and ImplantsMiddle AgedSensory SystemsSurgeryOphthalmologyMethacrylatesFemaleSurgeryIrritationbusinessJournal of Cataract and Refractive Surgery
researchProduct

Anterior Segment Biometry and Their Correlation with Corneal Biomechanics in Caucasian Children.

2018

Purpose: To assess the relationship between the corneal biomechanical parameters and the anterior segment parameters in Caucasian children. Methods: This study included 293 eyes from 293 healthy children aged between 6 and 17 years. Corneal hysteresis (CH) and corneal resistance factor (CRF) were evaluated with the Ocular Response Analyzer, axial length (AL) with IOLMaster and the anterior segment with Pentacam. Anterior segment parameters obtained were the following: central corneal thickness (CCT), corneal volume (CV), anterior chamber depth (ACD), anterior chamber volume (ACV) and mean anterior and posterior keratometry. Two multiple linear regression models were constructed to assess th…

Malemedicine.medical_specialtyBiometrygenetic structuresAdolescentanterior ocular segmentWhite Peoplelaw.inventionCorneal hysteresisCorrelationCorneaCorneal biomechanics03 medical and health sciencesCellular and Molecular Neuroscience0302 clinical medicinechildrenlawAnterior Eye SegmentReference ValuesStatistical significanceOphthalmologyLinear regressionMedicineHumansChildIntraocular PressureKeratometerbusiness.industryBiomechanicsCorneal TopographyAxial lengtheye diseasesSensory SystemsElasticityOphthalmologyCross-Sectional Studies030221 ophthalmology & optometryFemalesense organsocular response analyzerbusiness030217 neurology & neurosurgeryCurrent eye research
researchProduct

Cytokine expression in tears of patients with glaucoma or dry eye disease: A prospective, observational cohort study.

2018

Background: The aim of this study was to assess the expression of cytokines/chemokines in tears from patients with non-advanced primary open-angle glaucoma and patients with non-severe dry eye disease versus healthy controls. Methods: This prospective, observational cohort study enrolled patients with confirmed or suspected non-advanced primary open-angle glaucoma who received any prostaglandin analogue monotherapy for longer than 6 months, patients with non-severe dry eye disease, and healthy controls. Expression of interleukin-1β, interleukin-2, interleukin-4, interleukin-5, interleukin-6, interleukin-8, interleukin-10, and interleukin-12; tumor necrosis factor α; vascular endothelial gro…

Malemedicine.medical_specialtyChemokineGlaucomaInflammationDiseaseCohort Studies03 medical and health sciences0302 clinical medicineOphthalmologymedicineHumansProspective StudiesEye ProteinsAntihypertensive AgentsIntraocular PressureAgedbiologybusiness.industryPreservatives PharmaceuticalCytokine expressionGeneral MedicineMiddle Agedmedicine.diseaseOphthalmologyTears030221 ophthalmology & optometrybiology.proteinTearsCytokinesDry Eye SyndromesFemalemedicine.symptomOphthalmic Solutionsbusiness030217 neurology & neurosurgeryGlaucoma Open-AngleCohort studyEuropean journal of ophthalmology
researchProduct

Visual and optical performance with the ReZoom multifocal intraocular lens

2011

Purpose This study evaluated visual acuity, contrast sensitivity, and wavefront aberrations after refractive multifocal intraocular lens (IOL) implantation. Methods A prospective study comprising 174 eyes of 87 patients who had bilateral implantation of a multifocal IOL was carried out. A control group of 100 eyes of 50 age-matched patients with a monofocal IOL was used for comparison. Uncorrected and corrected distance and near visual acuity, contrast sensitivity (CS), and wavefront analysis (Hartmann-Shack) was performed 6 months after surgery. Contrast sensitivity was tested for distance and near under mesopic (2 cd/m2) and photopic conditions (90 cd/m2). Results Distance photopic CS was…

Malemedicine.medical_specialtyCorneal Wavefront AberrationVisual acuityPseudophakiagenetic structuresmedia_common.quotation_subjectVisual AcuityProsthesis DesignRefraction OcularContrast SensitivityLens Implantation IntraocularOphthalmologymedicineHumansContrast (vision)Prospective StudiesAgedmedia_commonAged 80 and overLenses IntraocularWavefrontVision Binocularbusiness.industryAberrometryGeneral MedicineMiddle AgedMultifocal intraocular lenseye diseasesOphthalmologyFemalemedicine.symptombusinessEuropean Journal of Ophthalmology
researchProduct

Prospective visual evaluation of apodized diffractive intraocular lenses

2006

To evaluate distance, intermediate, and near visual performance in patients who had multifocal apodized diffractive intraocular lens (IOL) implantation.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.The best corrected distance visual acuity, best distance-corrected near visual acuity, intermediate visual acuity, distance contrast sensitivity under photopic and mesopic conditions, and patient satisfaction were measured in 325 patients and 335 patients who had bilateral implantation of the model SA60D3 IOL (AcrySof ReSTOR, Alcon) and model SN60D3 IOL (AcrySof Natural ReSTOR), respectively.At the 6-month postoperative visit, binocular best corrected distance acuity with the ReSTOR IO…

Malemedicine.medical_specialtyDistance visual acuityPseudophakiagenetic structuresMesopic visionmedicine.medical_treatmentmedia_common.quotation_subjectAcrylic ResinsVisual AcuityIntraocular lensProsthesis DesignContrast SensitivityLens Implantation IntraocularSurveys and QuestionnairesOphthalmologymedicineHumansContrast (vision)In patientProspective StudiesAgedmedia_commonLenses IntraocularPhacoemulsificationbusiness.industryPhacoemulsificationMiddle Agedeye diseasesSensory SystemsOphthalmologyIntraocular lensesPatient SatisfactionQuality of LifeOptometryFemaleSurgerybusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Refractive lens exchange with Acri.LISA bifocal intraocular lens implantation.

2011

PURPOSE To assess efficacy, safety, and predictability after refractive lens exchange (RLE) in patients who had bilateral implantation of an Acri.LISA 366D diffractive bifocal intraocular lens (IOL). METHODS Sixty-six eyes of 33 consecutive patients were examined after RLE who had bilateral implantation of an Acri.LISA bifocal 366D IOL. Eyes were divided into myopic and hyperopic groups. Monocular uncorrected distance visual acuity, best-corrected distance visual acuity (BCVA), uncorrected distance near visual acuity, and best distance-corrected near visual acuity (BCNVA) were recorded preoperatively and 6 months after surgery. RESULTS Efficacy indexes were 0.73 for myopic and 0.85 for hype…

Malemedicine.medical_specialtyDistance visual acuityVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensRefractive lens exchangeNear visual acuityFunctional Laterality03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologymedicineMyopiaHumansIn patientLenses IntraocularPhacoemulsificationbusiness.industryGeneral MedicinePhacoemulsificationPresbyopiaPresbyopiaMiddle Agedmedicine.diseaseeye diseasesOphthalmologyHyperopiaTreatment Outcome030221 ophthalmology & optometryFemalesense organsmedicine.symptombusiness030217 neurology & neurosurgeryEuropean journal of ophthalmology
researchProduct

Prospective study of the Acri.LISA bifocal intraocular lens

2007

To assess the visual results after bilateral implantation of the bifocal Acri.LISA 366D intraocular lens (IOL) (Acri.Tec AG).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Eighty-one patients had bilateral implantation of the distance-dominant bifocal Acri.LISA 366D IOL in a prospective study. Monocular and binocular best corrected distance visual acuity and best distance-corrected near visual acuity, binocular best distance-corrected intermediate visual acuity, and distance contrast sensitivity under photopic (85 cd/m(2)) and mesopic (5 cd/m(2)) conditions were determined.At the 3-month postoperative visit, the mean binocular best corrected distance acuity was 0.048 +/- 0.111 log…

Malemedicine.medical_specialtyDistance visual acuitygenetic structuresMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensCataractContrast SensitivityNear acuityLens Implantation IntraocularOphthalmologyHumansMedicineContrast (vision)Prospective StudiesProspective cohort studyAgedmedia_commonLenses IntraocularVision BinocularPhacoemulsificationMonocularbusiness.industryMiddle Agedeye diseasesSensory SystemsOphthalmologyOptometryFemaleSurgerybusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Clear Lens Extraction with Multifocal Apodized Diffractive Intraocular Lens Implantation

2007

Purpose To assess efficacy, safety, predictability, and stability after clear lens extraction (CLE) with multifocal diffractive intraocular lens (IOL) implantation. Design Prospective, nonrandomized, masked observational case series (self-controlled). Participants Two hundred twenty-four eyes of 112 consecutive patients after CLE with bilateral AcrySof ReSTOR Natural IOL implantation. Eyes were divided into myopic (mean spherical equivalent [SE], −6.01±2.71 diopters [D]) and hyperopic (mean SE, +3.86±2.52 D) groups. Methods Monocular and binocular uncorrected distance visual acuity (VA), best-corrected distance VA, uncorrected distance near VA, and best distance-corrected near VA were recor…

Malemedicine.medical_specialtyDistance visual acuitygenetic structuresmedicine.medical_treatmentAcrylic ResinsVisual AcuityEmmetropiaIntraocular lensProsthesis DesignOphthalmoscopyTonometry OcularLens Implantation IntraocularOphthalmologyLens CrystallineMyopiamedicineHumansProspective StudiesDioptreAgedLenses IntraocularClear lens extractionPhacoemulsificationmedicine.diagnostic_testbusiness.industryPhacoemulsificationPresbyopiaMiddle Agedmedicine.diseaseeye diseasesOphthalmoscopyOphthalmologyHyperopiaTreatment OutcomeOptometryFemalesense organsbusinessOphthalmology
researchProduct