Search results for "AOC"

showing 10 items of 504 documents

A radiometric and petrographic approach to risk assessment at Alte Madonie Mounts region (Sicily, Italy)

2013

The main goal of this work was to assess the radiological hazard at Alte Madonie Mounts region (north-central Sicily, Italy) in response to rumours of an increase in the incidence of cancer in this area. A correlation between the natural radionuclide contents and the petrographic features of the soil and rock samples was also evaluated. A total of 41 samples of selected soils and rocks were collected, powdered, dried and sealed in 'Marinelli' beakers for 20 d prior to measurement to ensure that a radioactive equilibrium between (226)Ra and (214)Bi had been reached. A gamma-ray spectrometer was used to quantify the radioactivity concentrations. To determine (238)U and (232)Th activities, the…

ActiniumSettore ING-IND/20 - Misure E Strumentazione NucleariMineralogychemistry.chemical_elementRisk AssessmentNuclear physicsPetrographyRadiation MonitoringBackground RadiationSoil Pollutants RadioactiveRadiology Nuclear Medicine and imagingRadiometrySicilyRadioisotopesRadionuclideRadiationGeographyRadiological and Ultrasound TechnologyCarbonate radiaoctivity petrographyThoriumSettore GEO/07 - Petrologia E PetrografiaPublic Health Environmental and Occupational HealthThoriumGeneral MedicineSecular equilibriumUraniumSpectrometry GammaLinear relationshipchemistrySoil waterLinear ModelsPotassiumUraniumEnvironmental scienceRadiometric datingBismuthRadiumRadiation Protection Dosimetry
researchProduct

Preoperative simulation of postoperative iris-fixated phakic intraocular lens position and simulation of aging using high-resolution Scheimpflug imag…

2006

To increase postoperative safety after implantation of iris-fixated phakic intraocular lenses (pIOLs), optimal preoperative evaluation and patient selection is mandatory. We present a new software tool in a high-resolution Scheimpflug imaging device that precisely simulates the postoperative position of an iris-fixated pIOL and also simulates the effect of aging on the pIOL's position.

AdultAgingmedicine.medical_specialtygenetic structuresmedicine.medical_treatmentSoftware toolScheimpflug principleIrisHigh resolutionIntraocular lensPhakic intraocular lensPreoperative careImaging Three-DimensionalLens Implantation IntraocularAnterior Eye SegmentOphthalmologyLens CrystallinePreoperative CaremedicineHumansComputer SimulationPostoperative PeriodIris (anatomy)Lens crystallinebusiness.industryeye diseasesSensory SystemsOphthalmologymedicine.anatomical_structureFemaleSurgerysense organsbusinessJournal of Cataract and Refractive Surgery
researchProduct

Goldmann Tonometry After Hyperopic Laser In Situ Keratomileusis

2004

PURPOSE To identify differences in applanation tonometry between retreated and nonretreated eyes (primary LASIK eyes) 6 months after hyperopic laser in situ keratomileusis. METHODS In a prospective study 100 eyes (100 patients) underwent conventional hyperopic laser in situ keratomileusis under a 160-microm flap. Central Goldmann applanation tonometry was determined before and 6 months after surgery in 78 (78%) primary LASIK eyes and before surgery and 6 months after the retreatment date in 22 (22%) retreated eyes. RESULTS Preoperative mean tonometry was 14.96 +/- 1.96 mm Hg and 15.30 +/- 1.95 mm Hg in primary LASIK and retreated eyes, respectively. Six months after surgery it was 12.99 +/-…

AdultApplanation tonometrymedicine.medical_specialtyIntraocular pressureTime Factorsgenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SitueducationKeratomileusisGoldmann applanation tonometryTonometry OcularmedicineHumansPostoperative PeriodProspective StudiesIntraocular Pressurebusiness.industrySignificant differenceLASIKhumanitieseye diseasesSurgeryGoldmann tonometryOphthalmologyHyperopiaTreatment OutcomeRetreatmentsense organsbusinessCornea
researchProduct

Evaluation of the practicality of optical biometry and applanation ultrasound in 253 eyes

2003

Abstract Purpose To evaluate the percentage of eyes that could not be measured using optical biometry and ultrasound applanation and the reasons. Setting Department of Ophthalmology, Johannes Gutenberg-University Hospital, Mainz, Germany. Methods Optical biometry (IOLMaster®, Carl Zeiss Meditec AG) and A-scan ultrasound biometry were performed consecutively in 253 eyes scheduled for cataract surgery the next day. Lens opacities were evaluated with the Opacity Lensmeter (Interzeag), and a slitlamp examination and measurement of visual acuity were performed. The 2 techniques were compared in terms of the rate of and reasons for primary measurement failure. Results Measurement with the IOLMast…

AdultBiometryVisual acuityAdolescentLightPseudophakiagenetic structuresmedicine.medical_treatmentEye diseaseVision DisordersVisual AcuityIntraocular lensDiagnostic Techniques OphthalmologicalEyeRefraction OcularCataractOptical biometryLens Implantation IntraocularHumansMedicineChildAgedUltrasonographyAged 80 and overLenses Intraocularbusiness.industryUltrasoundMiddle AgedCataract surgerymedicine.diseaseeye diseasesSensory SystemsOptical axisOphthalmologyInterferometryChild PreschoolOptometrySurgerysense organsmedicine.symptombusinessPseudophakiaJournal of Cataract and Refractive Surgery
researchProduct

Spontaneous Resolution of Delayed Suprachoroidal Hemorrhage in the Single Eye Following Needling in Congenital Glaucoma

2017

Suprachoroidal hemorrhage (SCH) is a rare, but potentially vision-threatening event with poor long-term visual prognosis. At present, there is disagreement whether surgical intervention or conservative treatment is superior in the management. We report on a case of spontaneous resolution of severe SCH after needling procedure in the only eye of a young patient with congenital glaucoma.A 43-year-old woman with congenital glaucoma was scheduled for bleb needling in her only eye. Preoperative best-corrected visual acuity was 20/40 and intraocular pressure 20 mm Hg. On the third postoperative day, she developed a massive delayed SCH with appositional (kissing) choroidal bullae and visual acuity…

AdultChoroid Hemorrhagemedicine.medical_specialtyCongenital glaucomagenetic structuresRemission SpontaneousVisual AcuityGlaucomaSuprachoroidal hemorrhagePostoperative Hemorrhage03 medical and health sciences0302 clinical medicineOphthalmologyHumansMedicineIntraocular PressureDry needlingbusiness.industryGlaucomamedicine.diseaseConservative treatmentOphthalmology030221 ophthalmology & optometryDrainageFemalebusinessSclera030217 neurology & neurosurgeryJournal of Glaucoma
researchProduct

Visual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simula…

2012

AIMS: To evaluate the visual performance of an aberration-free intraocular lens (IOL) in patients with different corneal profiles using adaptive optics visual simulation. METHODS: A crx1 adaptive optics visual simulator was used to simulate the aberration pattern of an aberration-free IOL combined with five corneal profiles: virgin corneas and corneas with low and high myopic ablations and low and high hyperopic ablations. Ten eyes of 10 subjects were evaluated, and monocular distance visual acuity (VA) at 100%, 50% and 10% of contrast was measured. RESULTS: At 100% of contrast, no differences were found in VA values among virgin corneas, low and high myopic ablations and low hyperopic abla…

AdultCorneal Wavefront AberrationDistance visual acuityPseudophakiagenetic structuresmedia_common.quotation_subjectmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityIntraocular lensDiagnostic Techniques OphthalmologicalProsthesis DesignContrast SensitivityYoung AdultCellular and Molecular NeuroscienceLens Implantation IntraocularMyopiaHumansContrast (vision)MedicineIn patientAdaptive opticsSimulationmedia_commonLenses IntraocularPhacoemulsificationbusiness.industryAblationeye diseasesSensory SystemsOphthalmologySpherical aberrationHyperopiaOftalmologíaOptometryLasers Excimersense organsbusinessBritish Journal of Ophthalmology
researchProduct

Effect of Simulated IOL Tilt and Decentration on Spherical Aberration After Hyperopic LASIK for Different Intraocular Lenses

2011

PURPOSE: To evaluate visual quality differences among intraocular lenses (IOLs) in patients with previous hyperopic laser ablations and to assess the impact of decentration and tilt of IOLs on visual quality. METHODS: An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of one aberration-correcting IOL (AcrySof IQ SN60WF, Alcon Laboratories Inc) and two spherical IOLs with different amounts of positive spherical aberration (Akreos Adapt [Bausch & Lomb] and Triplato [AJL Ophthalmic]) in five situations—centered, 0.2 mm and 0.4 mm of decentration, and 2° and 4° of tilt—in two groups: simulated low hyperopic laser corneal ablation (low hyperopia group)…

AdultCorneal Wavefront AberrationDistance visual acuityVisual acuitygenetic structuresmedicine.medical_treatmentmedia_common.quotation_subjectKeratomileusis Laser In SituVisual AcuityArtificial Lens Implant MigrationRefraction OcularYoung AdultPostoperative ComplicationsHumansMedicineContrast (vision)media_commonLenses Intraocularbusiness.industryLASIKeye diseasesOphthalmologySpherical aberrationHyperopiaTilt (optics)Intraocular lensesDecreased Visual AcuityOftalmologíaOptometryLasers ExcimerSurgerysense organsmedicine.symptombusinessJournal of Refractive Surgery
researchProduct

Visual simulation through an aspheric aberration-correcting intraocular lens in subjects with different corneal profiles using adaptive optics.

2013

The aim of this study was to analyse the visual quality of the AcrySof IQ SN60WF® intraocular lens (IOL) when combined with different corneal profiles. Ten eyes of 10 participants with no prior history of refractive or cataract surgery were evaluated. An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of an aspheric aberration-correcting IOL (AcrySof IQ SN60WF®). Normal corneas (group A), low and high myopic corneal ablations (groups B and C, respectively) and low and high hyperopic corneal ablations (groups D and E, respectively) were also simulated. Monocular distance visual acuities at 100, 50 and 10 per cent of contrast were measured. At 100, 50 an…

AdultCorneal Wavefront Aberrationgenetic structuresComputer sciencebusiness.industrymedicine.medical_treatmentVisual AcuityIntraocular lenseye diseasesOphthalmologySpherical aberrationOpticsLens Implantation IntraocularmedicineMyopiaOptometryOftalmologíaHumanssense organsbusinessAdaptive opticsOptometryÓpticaClinicalexperimental optometry
researchProduct

Lentes de contato corneoesclerais adaptadas em córneas irregulares após cirurgia LASIK

2018

ABSTRACT Purpose: We aimed to describe the outcomes of corneoscleral contact lens fitting with multi-aspherical geometry designs in patients with irregular corneas after laser-assisted in situ keratomileusis (LASIK). Methods: This was a retrospective series of 18 patients (age, 26-38 years) selected from an eye clinic database. Participants were required to have unsatisfactory visual acuity with their current contact lenses or spectacles after LASIK for myopia correction. All patients were fitted with corneoscleral contact lenses designed to correct corneal surface irregularities. A diagnostic trial set was used for fitting, and assessments were performed according to a standardized methodo…

AdultCorneal surgery laserIntraocular pressuremedicine.medical_specialtyCorneal Wavefront AberrationVisual acuityPaquimetria corneanagenetic structuresIntraocular pressuremedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityLentes de contatoKeratomileusisCorneal endothelial cell losslaw.invention03 medical and health sciencesCorneal pachymetry0302 clinical medicinePerda de células endoteliais da córneaPressão intraocularlcsh:OphthalmologylawOphthalmologyMyopiaHumansMedicineContact lensesCorneal pachymetryCirurgia da córnea a laserRetrospective Studiesmedicine.diagnostic_testbusiness.industryCorneal TopographyLASIKGeneral MedicineContact Lenses HydrophilicCorneal topographyeye diseasesLens (optics)Contact lensOphthalmologylcsh:RE1-994030221 ophthalmology & optometrysense organsmedicine.symptombusiness030217 neurology & neurosurgeryFollow-Up Studies
researchProduct

Visual simulation through different intraocular lenses using adaptive optics: Effect of tilt and decentration

2011

Purpose To analyze visual quality differences between intraocular lenses (IOLs) and assess the impact of IOL decentration and tilt on visual quality. Setting University of Valencia, Valencia, Spain. Design Cohort study. Methods The crx1 adaptive optics visual simulator was used to simulate the wavefront aberration pattern of 2 commercially available aspheric aberration-correcting IOLs (Acrysof IQ SN60WF and Tecnis ZA9003) and 2 spherical IOLs (Akreos Adapt and Triplato) in 5 situations: centered, decentered 0.2 mm and 0.4 mm, and tilted 2 degrees and 4 degrees. Monocular distance visual acuity at 100%, 50%, and 10% contrast and the depth of focus were measured. Results Ten eyes of 10 patien…

AdultDepth of focusCorneal Wavefront AberrationVisual acuityPseudophakiagenetic structuresmedia_common.quotation_subjectVisual AcuityArtificial Lens Implant MigrationCohort StudiesYoung AdultAberrometryPsychophysicsmedicineHumansContrast (vision)Adaptive opticsmedia_commonMathematicsLenses IntraocularDepth PerceptionMonocularAberrometryModels Theoreticalequipment and supplieseye diseasesSensory SystemsOphthalmologySpherical aberrationTilt (optics)OptometrySurgerysense organsmedicine.symptomJournal of Cataract and Refractive Surgery
researchProduct