Search results for "AOC"

showing 10 items of 504 documents

Predictability of intraocular lens power calculation after small-incision lenticule extraction for myopia

2019

PURPOSE To evaluate and compare the predictability of intraocular lens (IOL) power calculation after small-incision lenticule extraction (SMILE) for myopia and myopic astigmatism. SETTING Department of Ophthalmology, Philipps University of Marburg, Marburg, Germany. DESIGN Retrospective comparative case series. METHODS Preoperative evaluation included optical biometry using IOLMaster 500 and corneal tomography using Pentacam HR. The corneal tomography measurements were repeated at 3 months postoperatively. The change of spherical equivalent due to SMILE was calculated by the manifest refraction at corneal plane (SMILE-Dif). A theoretical model, involving the virtual implantation of the same…

Optics and PhotonicsRefractive errormedicine.medical_specialtyBiometrymedicine.medical_treatmentIntraocular lensRefraction OcularMyopic astigmatism03 medical and health sciences0302 clinical medicineOptical biometryLens Implantation IntraocularGermanyOphthalmologyMyopiamedicineHumansSmall incision lenticule extractionDioptreRetrospective StudiesMathematicsLenses IntraocularPhacoemulsificationmedicine.diseaseSensory SystemsOphthalmology030221 ophthalmology & optometrySurgeryIntraocular lens power calculationRay tracing (graphics)030217 neurology & neurosurgeryJournal of Cataract and Refractive Surgery
researchProduct

Residual astigmatism produced by toric intraocular lens rotation.

2010

Purpose To analyze changes in the eye’s refractive properties when a toric intraocular lens (IOL) rotates. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Design Experimental study. Methods The matrix definition of astigmatism was used in this theoretical study and compared with another vector representation. Two methods were compared: (1) The cylinder, C, resulting from the addition of 2 cylinders C1 and C2 whose axes form an angle a, is obtained by the addition of 2 vectors of values C1 and C2 forming an angle 2a; (2) the power matrix, F, of a thin astigmatic dioptric system that decomposes naturally into 3 orthogonal components: the purely spherical part Fnes, the orth…

Optics and PhotonicsRotationmedicine.medical_treatmentIntraocular lensAstigmatismRotationRefraction OcularCylinder (engine)law.inventionOpticslawCorneamedicineHumansDioptreMathematicsAngle of rotationLenses Intraocularbusiness.industryAstigmatismModels Theoreticalmedicine.diseaseRefractionSensory SystemsOphthalmologymedicine.anatomical_structureSurgerybusinessMathematicsJournal of cataract and refractive surgery
researchProduct

Correlation between optics quality of multifocal intraocular lenses and visual acuity

2009

Purpose To study the relationship between the optics quality of multifocal intraocular lenses (IOLs) and distance-corrected near, intermediate, and distance visual acuity to determine the degree to which optics quality must change to produce a significant difference in visual acuity. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods Monocular distance-corrected visual acuity (decimal and logMAR) was measured at 4 m, 70 cm, and 30 cm under photopic and mesopic conditions in eyes with 1 of 3 multifocal IOL models. Visual acuity versus the “average modulation” of the IOL was assessed. Results The pupil diameter and patient age were similar between the 3 IOL groups (20 …

Optics and Photonicsmedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresMesopic visionColor visionmedicine.medical_treatmentVisual AcuityIntraocular lensPupilOpticsLens Implantation IntraocularOphthalmologymedicineHumansAgedRetrospective StudiesLenses IntraocularPhacoemulsificationColor VisionFourier Analysisbusiness.industryPupilPhacoemulsificationMultifocal intraocular lenseye diseasesSensory SystemsOphthalmologyOptometrySurgerysense organsmedicine.symptombusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Ahmed valve, suture-less implantation: A new approach to an easier technique.

2013

Purpose Tissue adhesives have been used in ophthalmology instead of sutures to minimize the operating time. This case series investigated the effectiveness and safety of use of cyanoacrylate in Ahmed valve implantation through pars plana for refractory glaucoma. Patients and methods Seventeen eyes of 17 patients with refractory glaucoma underwent Ahmed valve scleral suture-less implantation through pars plana with a cyanoacrylate suture of the plate. Refractory glaucoma was defined as intraocular pressure (IOP) ≥ 21 mm Hg with antiglaucoma eye drops, good adherence to treatment, and no previous glaucoma surgery. IOP control and development of complications were evaluated during the follow-u…

Pars planaAdultMalemedicine.medical_specialtyIntraocular pressureTime Factorsgenetic structuresAnterior Chambermedicine.medical_treatmentGlaucomaVitrectomyPilot ProjectsProsthesis ImplantationTonometry OcularPostoperative ComplicationsOphthalmologymedicineGlaucoma surgeryHumansCyanoacrylatesProspective StudiesGlaucoma Drainage ImplantsHyphemaIntraocular PressureAgedAged 80 and overbusiness.industrySuture TechniquesRetinal detachmentGlaucomaMiddle Agedmedicine.diseaseeye diseasesOphthalmologymedicine.anatomical_structureTreatment OutcomeVitreous hemorrhageFemalesense organsbusinessJournal of glaucoma
researchProduct

Intravitreal pegaptanib sodium for refractory pseudophakic macular oedema.

2008

Evaluate the efficacy of intravitreal pegaptanib sodium (Macugen®) in refractory pseudophakic cystoid macular oedema (CME). Prospective, nonrandomized, interventional case series. Four eyes of four patients with refractory pseudophakic CME to pars plana vitrectomy and intravitreal bevacizumab and triamcinolone, were treated with pegaptanib sodium, with a mean follow up of 4 months. Pre- and postinfection examinations included assessment of best-corrected visual acuity (BCVA) using the Early Treatment Diabetic Retinopathy Study chart (ETDRS), fluorescein angiography (FA), and optical coherence tomography (OCT). Visual acuity increased in all patients after intravitreal pegaptanib sodium. OCT…

Pars planaMalemedicine.medical_specialtyVisual acuityTriamcinolone acetonidegenetic structuresPseudophakiamedicine.medical_treatmentPegaptanibIntraocular lensVitrectomyAngiogenesis InhibitorsMacular EdemaVitrectomymedicinePegaptanib SodiumHumansProspective StudiesFluorescein AngiographyAgedDiabetic Retinopathymedicine.diagnostic_testbusiness.industryAptamers NucleotideMiddle AgedFluorescein angiographyeye diseasesSurgeryOphthalmologymedicine.anatomical_structureTreatment OutcomeFemalesense organsmedicine.symptombusinessTomography Optical Coherencemedicine.drugEye (London, England)
researchProduct

Efficacy and safety of the pars plana clip in the Ahmed valve device inserted via the pars plana in patients with refractory glaucoma

2010

Manuel Diaz-Llopis1,2,3, David Salom1,3, Salvador García-Delpech1,2,3, Patricia Udaondo1,3, Jose Maria Millan3,5, J Fernando Arevalo61Department of Ophthalmology, La Fe University Hospital of Valencia, Valencia, Spain; 2Department of Ophthalmology of the Valencia University, Valencia, Spain; 3Biomedical Network Research Centre on Rare Diseases (CIBERER), Valencia, Spain; 4Catholic University San Vicente Martir, Valencia, Spain; 5Department of Genetics, La Fe University Hospital of Valencia, Valencia, Spain; 6Clinica Oftalmologica Centro Caracas, Retina and VItreous Service, Caracas, DC, VenezuelaPurpose: To evaluate the efficacy and safety of the pars plana clip (PPC) in the Ahme…

Pars planamedicine.medical_specialtyIntraocular pressuregenetic structuresmedicine.medical_treatmentGlaucomaVitrectomyRefractoryAhmed valveOphthalmologyMedicineOriginal Researchpars plana vitrectomyIntraocular hemorrhageAhmed valvebusiness.industryClinical Ophthalmologymedicine.diseaseeye diseasesSurgerypars plana clipOphthalmologymedicine.anatomical_structurerefractory glaucomasense organsImplantbusinessClinical Ophthalmology
researchProduct

The eye in thyroid autoimmunity – Autoimmunité et œil lors de la maladie de Basedow

2014

Thyroid eye disease or thyroid-associated orbitopathy (TAO) is the commonest cause of orbital disease with an inflammatory component. With a basic knowledge of both orbital anatomy and the pathogenesis of TAO, it is easy to understand how its typical constellation of features originates. These features can be considered as primary or secondary. Primary features are those due directly to the disease process affecting a tissue e.g. restrictive myopathy. Secondary features occur due to the interaction of the affected tissue and the anatomical configuration of the tissues e.g. corneal ulceration or optic neuropathy, and are less likely to be florid at presentation. TAO is characterized by an im…

Pathologymedicine.medical_specialtybusiness.industryEndocrinology Diabetes and MetabolismThyroidInflammationGeneral Medicinemedicine.diseaseExtraocular muscleseye diseasesProinflammatory cytokineLymphocytic InfiltrateOptic neuropathyPathogenesisEndocrinologymedicine.anatomical_structureImmunologymedicinemedicine.symptomMyopathybusinessAnnales d'Endocrinologie
researchProduct

The Prevalence of Glaucoma in Young People.

2017

BACKGROUND Earlier information on the prevalence of glaucoma among children in Germany was based solely on estimates. Reported values for congenital glaucoma range from 1 in 10 000 to 1 in 68 000 depending on ethnic origin. The estimate for juvenile glaucoma is 1 in 44 000. METHODS The Gutenberg Health Study is a populationbased, prospective, monocentric cohort study with 15 010 participants aged 35 to 74. To determine the history-based prevalence of childhood glaucoma, participants were asked about the diagnosis of glaucoma, any operations for glaucoma that were performed, regular use of drugs for glaucoma, and the age of onset of glaucoma. The affected individuals were classified in four …

Pediatricsmedicine.medical_specialtyIntraocular pressureOpen angle glaucomagenetic structuresbusiness.industryCross-sectional studyGlaucomaGeneral Medicinemedicine.diseaseeye diseases03 medical and health sciences0302 clinical medicineCohort030221 ophthalmology & optometrymedicinesense organsAge of onsetProspective cohort studybusiness610 Medicine & health030217 neurology & neurosurgeryCohort study
researchProduct

Posterior chamber phakic intraocular lenses to improve visual outcomes in keratoconus patients

2016

The aim of this review is to summarize the results of using posterior chamber phakic intraocular lenses (pIOLs) to restore quality of vision in keratoconus patients. These pIOLs can correct the refractive errors associated with keratoconus and can also be combined with other surgical techniques to improve the results.

Phakic Intraocular Lensesmedicine.medical_specialtyKeratoconusgenetic structuresKeratoconusPhakic intraocular lens03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologyHumansMedicineLenses Intraocularbusiness.industryfungifood and beveragesRefractive Errorsmedicine.diseaseeye diseasesSensory SystemsOphthalmologyQuality of vision030221 ophthalmology & optometryOptometrySurgerysense organsbusiness030217 neurology & neurosurgeryJournal of Cataract and Refractive Surgery
researchProduct

Modulation transfer function: Rigid versus foldable phakic intraocular lenses

2008

Purpose To study in a standard eye model the changes in modulation transfer function (MTF) of a monofocal intraocular lens (IOL) when a phakic IOL (pIOL) is placed in the anterior chamber, compare the MTFs of the rigid Artisan pIOL and foldable Artiflex pIOL, and evaluate the temporal evolution of the MTF of the foldable pIOL after the mechanical stress the pIOL undergoes when injected. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods The MTF values of the IOLs were calculated from the cross-line spread function recorded with the Opal Vector System. The measurements were taken using an eye model following the British and EN-ISO standards with 2.0 mm, 3.0 mm, 4.0 mm…

Phakic Intraocular Lensesmedicine.medical_specialtyMaterials scienceOptical PhenomenaAnterior Chambermedicine.medical_treatmentIntraocular lensPhakic intraocular lensModels BiologicalSensory SystemsOptical qualityPupillaw.inventionLens (optics)OphthalmologyLens Implantation IntraocularlawOphthalmologyOptical transfer functionMyopiamedicineHumansSurgeryPhakic iolDioptreJournal of Cataract and Refractive Surgery
researchProduct