Search results for "AOC"

showing 10 items of 504 documents

The posterior chamber phakic refractive lens (PRL): a review

2012

Implantation of phakic intraocular lenses (pIOLs) is a reversible refractive procedure, preserving the patient’s accommodative function with minimal induction of higher order aberrations compared with corneal photoablative procedures. Despite this, as an intraocular procedure, it has potential risks such as cataracts, chronic uveitis, pupil ovalization, corneal endothelial cell loss, pigmentary dispersion syndrome, pupillary block glaucoma, astigmatism, or endophthalmitis. Currently, only two models of posterior chamber pIOLs are commercially available, the implantable collammer lens (STAAR Surgical Co.) and the phakic refractive lens (PRL; Zeiss Meditec). The number of published reports on…

Phakic Intraocular Lensesmedicine.medical_specialtygenetic structuresmedicine.medical_treatmentVisual performanceOptical qualityReviewAstigmatismRefraction OcularPhakic intraocular lensPhakic refractive lens (PRL)CataractPupilEndophthalmitisLens Implantation IntraocularCataractsOphthalmologyRefractive surgeryMyopiamedicineHumansRefractive surgeryÓpticaPosterior chamber phakic intraocular lensbusiness.industryPatient SelectionEquipment Designmedicine.diseaseeye diseasesOphthalmologyAberrations of the eyemedicine.anatomical_structureLens (anatomy)Posterior Capsule of the LensOptometrysense organsbusinessEye
researchProduct

A/V ratio as predicted by full width at half maximum and by blood vessel tracking in presence of ocular aberrations

2011

Aberrations impact A/V ratio calculated from full width at half maximum. We investigated whether aberrations affect A/V ratio calculated by tracking the vessels. Aberrations changed the A/V ratio. We conclude that aberrations impact A/V ratio.

PhysicsFull width at half maximummedicine.anatomical_structureOpticsIntraocular lensesbusiness.industrymedicineTracking (particle physics)businessAdaptive opticsBlood vesselScanning laser ophthalmoscopy
researchProduct

In vitro optical quality differences between multifocal apodized diffractive intraocular lenses.

2013

Purpose To compare the in vitro optical quality of multifocal apodized intraocular lenses (IOLs) at different focal points. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods The Acrysof Restor +3.0 diopter (D) multifocal IOL with 2 main foci (bifocal IOL) and the Finevision multifocal IOL with 3 main foci (trifocal IOL) were evaluated. The optical quality was quantified using the modulation transfer function (MTF) at 7 focal points and for 3.0 mm and 4.5 mm apertures. The through-focus MTF at 10 focal points of the IOLs was also recorded. Results For the 0.0 D and −2.5 D focal points, the bifocal IOL showed the highest MTF values for pupil sizes as well as …

PhysicsLenses IntraocularFocal pointOptics and Photonicsbusiness.industryApertureProsthesis DesignSensory SystemsOptical qualityOphthalmologyOpticsCardinal pointApodizationIntraocular lensesOptical transfer functionSurgeryVisual FieldsbusinessDioptreVision OcularJournal of cataract and refractive surgery
researchProduct

Modulation transfer function of a toric intraocular lens: evaluation of the changes produced by rotation and tilt.

2011

PURPOSE: To evaluate the changes in optical quality when toric intraocular lenses (IOL) are rotated or tilted and to demonstrate that IOL rotation produces an increasing effect of aberrations. METHODS: Modulation transfer function (MTF) and average modulation were used to analyze the image quality of a toric IOL. The axis of the toric IOL was rotated 5°, 10°, 15°, 20°, 25°, and 30° in successive MTF measurements. The tilt values were 0° to 5°, in increments of 1°, plus a tilt of 15°. Pupil diameters of 3 and 5 mm were used. RESULTS: The MTF decay due to aberrations was more sensitive to rotation than tilt. The main decrement in the average modulation, of approximately 50% in both pupils, o…

PhysicsLenses IntraocularOptics and PhotonicsCorneal Wavefront AberrationRotationbusiness.industrymedicine.medical_treatmentIntraocular lensModels TheoreticalRotationArtificial Lens Implant MigrationOptical qualityExponential functionOphthalmologyTilt (optics)OpticsIntraocular lensesModulationOptical transfer functionmedicineHumansSurgerybusinessJournal of refractive surgery (Thorofare, N.J. : 1995)
researchProduct

Influencia del modelo de ojo teórico en la evaluación numérica de lentes intraoculares fractales

2020

In this work we present the numerical evaluation of a new design of fractal intraocular lens studied through a ray-tracing program. To determine the monochromatic and polychromatic performance of these lenses in different theoretical model eyes the Modulation Transfer Function (MTF) and the area above the MTF (AMTF) have been used. These merit functions show the same behavior for different values of asphericity (Q), independently from the theoretical model eye, even though there are differences due to the Spherical Aberration (SA) considered in each model.

PhysicsSpherical aberrationOpticsFractalbusiness.industryOptical transfer functionmedicine.medical_treatmentmedicineIntraocular lensMonochromatic colorbusinessSuplemento de la Revista Mexicana de Física
researchProduct

Implantable collamer lens and femtosecond laser for myopia: comparison using an adaptive optics visual simulator.

2014

Purpose: To compare optical and visual quality of implantable collamer lens (ICL) implantation and femtosecond laser in situ keratomileusis (F-LASIK) for myopia. Methods: The CRX1 adaptive optics visual simulator (Imagine Eyes, Orsay, France) was used to simulate the wavefront aberration pattern after the two surgical procedures for -3-diopter (D) and -6-D myopia. Visual acuity at different contrasts and contrast sensitivities at 10, 20, and 25 cycles/degree (cpd) were measured for 3-mm and 5-mm pupils. The modulation transfer function (MTF) and point spread function (PSF) were calculated for 5-mm pupils. Results: F-LASIK MTF was worse than ICL MTF, which was close to diffraction-limited MT…

Point spread functionAdultLaser de excimerPhakic Intraocular LensesVisual acuityVisual acuitymedicine.medical_treatmentKeratomileusis Laser In SituLentes intraoculares; Sensibilidade de contrasteVisual AcuityCeratomileuse assistida por excimer laser in situ/métodosKeratomileusisPhakic intraocular lensMyopia/surgeryPupilKeratomileusis laser in situ/methodsContrast SensitivityYoung Adultlcsh:OphthalmologyLens Implantation IntraocularOptical transfer functionmedicineMyopiaHumansComputer SimulationContrast sensitivityAdaptive opticsSimulationPhysicsLasers excimer/therapeutic useAcuidade visualAberrometryAccommodation OcularGeneral MedicineOphthalmologyTreatment Outcomelcsh:RE1-994Lenses intraocularMiopia/cirurgiaOptometrySpatial frequencymedicine.symptomArquivos brasileiros de oftalmologia
researchProduct

Myopic astigmatism correction: comparison of a Toric Implantable Collamer Lens and a bioptics technique by an adaptive optics visual simulator.

2013

Purpose To compare the optical and visual quality of a simulated Toric Implantable Collamer Lens (TICL) and a bioptics technique to treat high myopic astigmatism. Methods An adaptive optics visual simulator was used to simulate the vision after TICL implantation and a bioptics procedure from the wavefront aberration pattern for moderate and high-myopic astigmatism. Visual acuity (VA) at different contrasts and contrast sensitivity (CS) at 10, 20 and 25 cycles degree−1 were measured for 3 and 5-mm pupils. Modulation Transfer Function (MTF) and Point Spread Function (PSF) were calculated for a 5-mm pupil. Results At a 3-mm pupil we only found statistically significant differences in VA betwee…

Point spread functionAdultMalePhakic Intraocular LensesVisual acuityCorneal Wavefront AberrationAdolescentVisual AcuityAstigmatismPupilContrast SensitivityYoung AdultBioptics (surgery)Lens Implantation IntraocularOptical transfer functionmedicineMyopiaHumansAdaptive opticsSimulationMathematicsAberrometryAstigmatismmedicine.diseaseSensory SystemsOphthalmologyFemaleSpatial frequencymedicine.symptomOptometryOphthalmicphysiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)
researchProduct

Through-focus response of multifocal intraocular lenses evaluated with a spatial light modulator

2012

A new testing technique based on the use of a liquid crystal spatial light modulator (SLM) is proposed to analyze the optical quality of multifocal intraocular lenses (MIOLs). Different vergences and decentrations of the incident beam can be programmed onto the SLM in order to record the point spread function (PSF) for different object positions. From these axial PSFs, the through-focus modulation transfer function is computed. Because there are no moving parts in the experimental setup, this method is fast and versatile to assess MIOLs. Experimental results confirm the potential of the proposed method.

Point spread functionMaterials scienceImage qualityProsthesis DesignOpticsIn-vivoOptical transfer functionDefocus transfer-functionImage qualityDecentrationElectrical and Electronic EngineeringEngineering (miscellaneous)LightingTiltLenses IntraocularSpatial light modulatorbusiness.industryOptical-performanceMultifocal intraocular lensAtomic and Molecular Physics and OpticsEquipment Failure AnalysisRefractometryAberrationsTilt (optics)DesignsFISICA APLICADASpatial frequencybusinessFocus (optics)Applied Optics
researchProduct

Optical Characterization Method for Tilted or Decentered Intraocular Lenses

2016

Purpose To test and validate a method for measuring the optical quality and optical power of monofocal intraocular lenses (IOLs) in the presence of a tilt or a decentration as well as its optical power. Methods The experimental system consists of an artificial eye (wet-cell) and a commercial aberrometer with a Shack-Hartmann sensor. Optical image quality parameters such as point spread function (PSF), modulation transfer function (MTF), and the simulations of the retinal image of an extended object are computed from the in vitro wavefront data of an IOL. Repeatability and reproducibility of the system are tested. Mathematical and ray-tracing simulations are used to ascertain the precision a…

Point spread functionOptics and PhotonicsAccuracy and precisionMaterials sciencePseudophakiaOptical powerArtificial Lens Implant Migration01 natural sciences010309 optics03 medical and health sciences0302 clinical medicineOpticsLens Implantation IntraocularOptical transfer function0103 physical sciencesHumansLenses IntraocularWavefrontReproducibilitybusiness.industryAberrometryReproducibility of ResultsRepeatabilityModels TheoreticalOphthalmologyTilt (optics)030221 ophthalmology & optometrybusinessOptometryOptometry and Vision Science
researchProduct

Evaluation of the performance of multifocal intraocular lenses image quality: analysis of the standard methods

2007

Purpose: To analyze the standard methods used to describe intraocular lenses (IOL) and to suggest some improvements to make them applicable for multifocal IOLs. Methods: The EN-ISO standards and the standards of the American National Standards Institute (ANSI) for the evaluation of the performance of IOLs are tested for multifocal IOLs. The MTF of the one refractive multifocal IOL and two hybrid refractive-diffractive multifocal IOLs is measured for both distance focus and near focus and using different pupil sizes. Results: The average modulation (AM) from 0 to 100 c/mm of multifocal IOLs (for the distance focus) is about 40-50% lower than the AM of monofocal IOLs, for all pupil sizes stud…

Point spread functionbusiness.industryPupil sizeMultifocal intraocular lensStandard methodsPupilOphthalmologyOpticsImage quality analysisIntraocular lensesOptometryMultifocal IOLsMedicinebusinessActa Ophthalmologica Scandinavica
researchProduct