Search results for "AOC"

showing 10 items of 504 documents

Schematic eye models to mimic the behavior of the accommodating human eye

2018

A simplified version of the human eye is known as schematic eye model. Since the first attempts in the middle of the 19th century, numerous approaches describing new schematic eye models have been introduced. Some of them are able to describe the accommodation ability of the human eye. Accommodative schematic eyes could be of great interest since they are able to explain the functionality of the human eye and they can be easily used for different research purposes. Some of these include the design and testing of multifocal ophthalmic solutions, evaluation of the effect of optical aberrations on the retinal image quality, and study of the optical performance of the eye at different distances…

genetic structuresComputer scienceComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONSchematic eyeModels Biological01 natural sciencesCornea010309 optics03 medical and health sciencesOcular physiology0302 clinical medicine0103 physical sciencesmedicineHumansbusiness.industryAccommodation OcularSchematicSurgical proceduresÒpticaRefractive ErrorsSensory SystemsRetinal imageeye diseasesOphthalmologymedicine.anatomical_structureIntraocular lenses030221 ophthalmology & optometryOptometrySurgeryHuman eyesense organsbusinessAccommodationUlls
researchProduct

A new trifocal corneal inlay for presbyopia

2021

[EN] Corneal inlays (CIs) are the most recent surgical procedure for the treatment of presbyopia in patients who want complete independence from the use of glasses or contact lenses. Although refractive surgery in presbyopic patients is mostly performed in combination with cataract surgery, when the implantation of an intraocular lens is not necessary, the option of CIs has the advantage of being minimally invasive. Current designs of CIs are, either: small aperture devices, or refractive devices, however, both methods do not have good performance simultaneously at intermediate and near distances in eyes that are unable to accommodate. In the present study, we propose the first design of a …

genetic structuresComputer sciencemedicine.medical_treatmentScienceVisual AcuityBiophysicsFOS: Physical sciencesIntraocular lens01 natural sciencesArticle010309 opticsCornea03 medical and health sciences0302 clinical medicineRefractive surgery0103 physical sciencesmedicineHumans03.- Garantizar una vida saludable y promover el bienestar para todos y todas en todas las edadesIn patientAdaptive opticsMultidisciplinaryInlayVision TestsQRPresbyopiaPresbyopiaCataract surgerymedicine.diseasePhysics - Medical PhysicsCorneal inlayeye diseasesRefractive Surgical ProceduresTreatment OutcomeOptics and photonicsPreclinical researchFISICA APLICADA030221 ophthalmology & optometryOptometryMedicineMedical Physics (physics.med-ph)sense organsPhysics - OpticsOptics (physics.optics)
researchProduct

Teprotumumab reduces extraocular muscle and orbital fat volume in thyroid eye disease

2020

PurposeThyroid eye disease (TED) is a progressive, debilitating and potentially vision-threatening autoimmune disease. Teprotumumab, a novel human monoclonal antibody, has been shown to reverse the clinical manifestations of TED. Patients receiving teprotumumab have been shown in two multicenter, randomized placebo-controlled trials to have decreased proptosis, diplopia and inflammation after 24 weeks of treatment. This study aims to analyse volumetric and inflammatory changes on orbital imaging prior to and after teprotumumab treatment from one of these trials.DesignRetrospective review.SubjectsSix patients enrolled in the phase III teprotumumab clinical trial (OPTIC, NCT03298867) with act…

genetic structuresEye disease030209 endocrinology & metabolismAntibodies Monoclonal HumanizedExtraocular muscles03 medical and health sciencesCellular and Molecular Neuroscience0302 clinical medicineOrbital fatmedicineHumansInflammationAutoimmune diseaseDiplopiabusiness.industryTeprotumumabThyroidmedicine.diseaseeye diseasesSensory SystemsGraves OphthalmopathyOphthalmologymedicine.anatomical_structureOculomotor Muscles030221 ophthalmology & optometrysense organsmedicine.symptomNuclear medicinebusinessOrbitOrbit (anatomy)medicine.drugBritish Journal of Ophthalmology
researchProduct

Validation of a spectral light scattering method to differentiate large from small particles in intraocular lenses

2017

A psychophysical approach has been designed to measure straylight from intraocular lenses (IOLs) in vitro. This approach uses a clinical straylight meter (C-Quant) and an observer's eye as optical detector. Based on this, we introduced a method for study of straylight-wavelength dependency for IOLs. This dependency can be used to distinguish between 2 types of scattering particles (small and large) as defined by Mie theory. Validation was performed using a turbidity standard and scattering filters. Several IOLs were analyzed to identify potential scattering sources. Large particles were found to predominate in scattering from the studied lenses. This was confirmed by straylight-angular depe…

genetic structuresForward scatterOptical detectorMie scattering01 natural sciencesLight scatteringArticle010309 optics03 medical and health sciencessymbols.namesake0302 clinical medicineOptics0103 physical sciencesJournal ArticleSmall particlesRayleigh scatteringPhysicsScatteringbusiness.industryequipment and suppliesAtomic and Molecular Physics and Opticseye diseasesIntraocular lenses030221 ophthalmology & optometrysymbolssense organsbusinessBiotechnologyBiomedical Optics Express
researchProduct

Subjective photic phenomena with refractive multifocal and monofocal intraocular lenses. results of a multicenter questionnaire.

2001

Abstract Purpose To compare the incidence and severity of photic phenomena after the implantation of the Array® (Allergan) refractive multifocal intraocular lens (MIOL) and a monofocal IOL. Setting Multicenter study at Kiel, Mainz, Karlsruhe, and Bremerhaven, Germany. Methods The study comprised 231 randomly selected patients from 4 study centers. The patients had had uneventful phacoemulsification with implantation of a refractive MIOL (n = 138) or a monofocal IOL (n = 93). By questionnaire, patients were asked whether they experienced light sensations postoperatively (light streaks, halos, flare, flashes, or glare) that had not been noticed preoperatively. Additional questions evaluated w…

genetic structuresLightmedicine.medical_treatmentEye diseaseVision DisordersIntraocular lensGlareVision disorderLens Implantation IntraocularSurveys and QuestionnairesmedicineHumansLenses IntraocularPhacoemulsificationbusiness.industryIncidenceGlare (vision)PhacoemulsificationMultifocal intraocular lensCataract surgerymedicine.diseaseeye diseasesSensory SystemsOphthalmologyMulticenter studyOptometrySurgerysense organsmedicine.symptombusinessJournal of cataract and refractive surgery
researchProduct

Tear production and intraocular pressure values in clinically normal eyes of whooper swans (Cygnus cygnus)

2018

The objective of this study was to determine the normal range of tear production and values of intraocular pressure (IOP) in clinically normal eyes of whooper swans (Cygnus cygnus). A total of 86 birds: 81 cygnets (6-10 weeks old) and 5 moulting – adult swans (3-6 years old) were examined in this study. Both eyes of all birds underwent a complete ophthalmic examination, including evaluation of tear production with the phenol red thread test (PRTT) and the assessment of the IOP by rebound tonometry, employing the TonoVet® device. The mean ± standard deviation of PRTT values were as follows: all cygnets (81) 22.59±3.48 mm/15s, male cygnets (45) 22.64±3.54 mm/15s, female cygnets (36) 22.53±3.4…

genetic structuresQL1-991Intraocular pressurePhenol red thread testEye Intraocular pressure Phenol red thread test Tear production Whooper swanWhooper swanOriginal Articlesense organsTear productionEyeZoologyeye diseasesOpen Veterinary Journal
researchProduct

Modulation transfer function in refractive-diffractive multifocal intraocular lenses in vitro

2007

Purpose: The optical quality of two types of multifocal, hybrid refractive-diffractive, intraocular lenses (IOL) is analyzed in vitro. Following the EN-ISO international standard, the IOLs’ modulation transfer functions (MTF) are determined for both distance and near vision. The behaviour of these curves when the pupil size varies is studied. Methods: The IOLs analyzed were: AcrySoft ResTor SN60D3 (Alcon) and Tecnis ZM900 (AMO). The MTF was calculated from the cross line-spread function recorded with the OPAL Vector System (Image Science Ltd. Oxford) by using fast Fourier transform techniques. The artificial eye model used simulates in vivo conditions of the anterior chamber including an ar…

genetic structuresbusiness.industryImage qualityStrehl ratioMultifocal intraocular lenseye diseasesPupilOptical qualityOphthalmologyOpticsIntraocular lensesOptical transfer functionMedicinesense organsImaging sciencebusinessActa Ophthalmologica Scandinavica
researchProduct

Computed Tomography in Orbital Lesions

1981

Lesions in the orbits are characterized by unilateral or bilateral proptosis and/or disorders of ocular motion. Before the advent of computed tomography diagnosis was made on the basis of conventional radiological studies of the skull and the orbits as well as with ultrasonog-raphy, fluorescence angiography, phlebography of the ophthalmic vein, and arteriograms of the internal and external carotid arteries. The introduction of CT has brought about a correspondingdecline in the use of invasive procedures (Wende et al. 1977).

genetic structuresmedicine.diagnostic_testFluorescence angiographybusiness.industryCarotid arteriesComputed tomographyLacrimal glandExtraocular muscleseye diseasesSkullmedicine.anatomical_structureOptic nervemedicineVeinNuclear medicinebusiness
researchProduct

Multifokale Intraokularlinsen

2001

Modern cataract surgery has developed tremendously during the past 10-15 years. Improved surgical techniques, as well as improved implant materials and designs, have enlarged patient profiles and indications for cataract surgery. This also created much higher expectations from the patients' site. The loss of accommodation is loss of quality of life for presbyopic and especially young pseudophakic patients. Therefore cataract surgery with multifocal IOL implantation is not only of academic interest, but reflects demands and expectations of our patients. Multifocal IOLs have been implanted since 1986, starting with 2-3 zone refractive and diffractive designs. Due to surgical techniques of tha…

genetic structuresmedicine.diagnostic_testbusiness.industrymedicine.medical_treatmentEye diseaseGlare (vision)Intraocular lensCataract surgeryCorneal topographymedicine.diseaseAphakiaeye diseasesOphthalmologymedicineOptometryMultifocal IOLssense organsImplantbusinessDer Ophthalmologe
researchProduct

Visual and refractive outcomes in hyperopic pseudophakic patients implanted with a trifocal intraocular lens

2019

José F Alfonso,1,2 Andrés Fernández-Vega-Cueto,1 Belén Alfonso-Bartolozzi,1 Ignacio Rodríguez-Uña,1 Robert Montés-Micó3 1Corneal and Lens Surgery Department, Fernández-Vega Ophthalmological Institute, Oviedo, Spain; 2Surgery Department, School of Medicine, University of Oviedo, Oviedo, Spain; 3Optics and Optometry and Vision Sciences Department, Faculty of Physics, University of Valencia, Valencia, SpainCorrespondence: José F AlfonsoInstituto Oftalmológico Fernández-Vega, Avda. Dres. Fernández-Vega 114, Oviedo 33012, SpainTel +34 985 245533Fax +34 98…

hyperopiagenetic structurescataractphacoemulsificationtrifocal intraocular lensClinical Ophthalmologysense organseye diseasesOriginal Research
researchProduct