Search results for "ARTHROPLASTY"

showing 10 items of 163 documents

The internal calcar septum and its contact with the virtual stem in THR: a computer tomographic evaluation.

2003

The internal calcar septum is a ridge of cortical bone protruding from the inner cortical wall of the proximal femur into the medullary canal. It extends from the lesser trochanter into the femoral neck and narrows the femoral cavity in its dorsal third. This region is essential for THR stability, but the degree of contact between the septum and standard THR implants has never been studied. We obtained CT scans of 50 arthrotic hip joints from patients requiring THR. Virtual stems (50 straight/wedge-shaped and 50 anatomic stems) were placed in CT images of the femora using a PC-based preoperative planning unit. The dimensions of the septum, degree and location of contact between the septum a…

Adultmedicine.medical_specialtyCalcarMedullary cavitybusiness.industryArthroplasty Replacement HipAnatomyRoboticsMiddle Agedmedicine.anatomical_structureLesser TrochanterOrthopedic surgerymedicineImage Processing Computer-AssistedHumansOrthopedics and Sports MedicineSurgeryCortical boneFemurImplantFemurHip ProsthesisbusinessTomography X-Ray ComputedFemoral neckActa orthopaedica Scandinavica
researchProduct

Bilateral synovial chondromatosis of the temporomandibular joint.

2009

Abstract Purpose To report an exceptional case of bilateral synovial chondromatosis (SC) of the temporomandibular joint (TMJ) and discuss diagnostic approaches, treatment options and follow-up data. Patients and methods A 38-year-old woman presented with left preauricular swelling. Initial imaging studies revealed TMJ effusion only. Six years later, synovial calcifications were detected in the left TMJ; the right TMJ space was widened and presented incipient calcium deposits. Open arthrotomy of the left TMJ was performed, with removal of multiple cartilaginous loose bodies and complete synovectomy. Periodic controls proved the asynchronic development of intra-articular bodies in the right T…

Adultmedicine.medical_specialtymedicine.medical_treatmentSynovectomyOsteochondromatosisArthroplastyDiagnosis Differentialstomatognathic systemSynovial chondromatosisFacial PainSynovectomyArthropathyMedicineHumansHearing LossArthrotomymedicine.diagnostic_testTemporomandibular Jointbusiness.industryHeadacheMagnetic resonance imagingTemporomandibular Joint Disordersmedicine.diseaseMagnetic Resonance ImagingSurgeryTemporomandibular jointstomatognathic diseasesmedicine.anatomical_structureOtorhinolaryngologySurgeryChondromatosisFemaleOral SurgerybusinessTomography X-Ray ComputedChondromatosis SynovialJournal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery
researchProduct

Funkcionālo un radioloģisko rezultātu salīdzinājums pacientiem pēc pleca locītavas endoprotezēšanas ar Global Icon™ Stemless un Global Unite® anatomi…

2021

Darba aktualitāte: Pleca locītavas endoprotezēšana ir viena no ķirurģiskās ārstēšanas metodēm osteoartrīta slimībai. Mūsdienu tehnoloģiskās iespējas nodrošina endoprotēžu attīstību un daudzveidību. Aizstājot pacienta dabīgo locītavu ar mākslīgo implantu, svarīgi ir izvēlēties viņa stāvoklim, ikdienas aktivitātēm un prasībām atbilstošāko protēzes veidu, lai sasniegtu labāko pēcoperācijas rezultātu. Darba mērķis: Salīdzināt Global Icon anatomiskās bezkājiņas implanta efektivitāti ar Global Unite implanta ar kājiņu efektivitāti, izvērtējot klīniskos un radioloģiskos rezultātus gadu pēc operācijas. Darba uzdevumi: Veikt CMS rezultātu analīzi pirms operācijas un gadu pēc endoprotezēšanas operāci…

Anatomic total shoulder arthroplastyGlobal IconGlobal UniteConstant-Murley skalaAnatomic stemmless prosthesisMedicīna
researchProduct

Complement split products and proinflammatory cytokines in intraoperatively salvaged unwashed blood during hip replacement: comparison between hepari…

2008

Background and Objectives  The aim of the present study was to investigate the quality of shed blood collected in a new intraoperative autotransfusion system (Sangvia®, AstraTech, Sweden) and to study whether heparin-coated surfaces in the device reduce the production of inflammatory mediators. Material and Methods  The study was randomized and prospective. Twelve total hip arthroplasty patients whose blood was collected with a device having a heparin-coated surface and 12 patients whose blood was collected with a device having a non-heparin-coated surface were included. Venous blood was drawn from the patients preoperatively. Intraoperatively 200 ml salvaged blood was collected and samples…

Arthroplasty Replacement HipBlood Loss SurgicalHip replacement (animal)Proinflammatory cytokineBlood Transfusion AutologousCoated Materials BiocompatibleHumansMedicineInterleukin 6Hip surgeryIntraoperative CarebiologyHeparinbusiness.industryHematologyGeneral MedicineHeparinVenous bloodAnesthesiaComplement C3abiology.proteinCytokinesbusinessAutotransfusionmedicine.drugTotal hip arthroplastyVox Sanguinis
researchProduct

Periacetabular Cortical and Cancellous Bone Mineral Density Loss After Press-Fit Cup Fixation

2012

The impact of total hip arthroplasty on strain adaptive bone remodeling has been extensively analyzed by dual-energy x-ray absorptiometry. In this study, we present a prospective computed tomography-assisted study of periacetabular cortical and cancellous bone mineral density (in milligrams of calcium hydroxyapatite [CaHA] per milliliter, or mgCaHA/mL) changes 10 days and 1, 3, and 7 years after press-fit cup implantation for 38 hips in vivo. Cancellous bone mineral density decreased by O -63% ventral and O -85% dorsal to the cup; cortical bone mineral density, by O -22% ventral and O -18% dorsal to the cup. The presented periacetabular strain adaptive bone mineral density data are the most…

Bone mineralmedicine.diagnostic_testbusiness.industrymedicine.medical_treatmentAnatomyAcetabulumArthroplastyBone remodelingmedicine.anatomical_structuremedicineOrthopedics and Sports MedicineCortical bonebusinessCancellous boneDual-energy X-ray absorptiometryFixation (histology)The Journal of Arthroplasty
researchProduct

Clinical and functional comparison between different surgical approaches to total hip arthroplasty

2012

Clinicalhip arthroplastySettore BIO/09 - Fisiologia
researchProduct

JABB: Moving Towards The Future.

2012

Computer sciencebusiness.industryPrimary stabilityBiomedical EngineeringBiophysicsBioengineeringBiocompatible MaterialsGeneral MedicineData scienceBiomechanical PhenomenaBiomaterialsText miningTotal knee arthroplastyCruciate retainingOriginal ArticlePeriodicals as TopicbusinessTransversal support tibial plateauForecastingJournal of applied biomaterialsfunctional materials
researchProduct

Analysis of different geometrical features to achieve close-to-bone stiffness material properties in medical device: A feasibility numerical study

2021

Background and objective: In orthopedic medical devices, elasto-plastic behavior differences between bone and metallic materials could lead to mechanical issues at the bone-implant interface, as stress shielding. Those issue are mainly related to knee and hip arthroplasty, and they could be responsible for implant failure. To reduce mismatching-related adverse events between bone and prosthesis mechanical properties, modifying the implant's internal geometry varying the bulk stiffness and density could be the right approach. Therefore, this feasibility study aims to assess which in-body gap geometry improves, by reducing, the bulk stiffness. Methods: Using five finite element models, a unia…

Elastic ModulusArthroplasty Replacement HipIn-body gapsFinite Element AnalysisFeasibility StudiesHealth InformaticsStress MechanicalArthroplasty Replacement KneeSoftwareComputer Science ApplicationsMaterial stiffness
researchProduct

In Silico Evaluation of Treatment of Periprosthetic Fractures in Elderly Patients After Hip Arthroplasty

2021

The aim of this study was to investigate the soundness of in silico finite element model (FEM) in the assessment of strain in the femur and in the components fixing the periprosthetic fracture in elderly patients after hip arthroplasty. From a group of 55 patients, aged 27–95, treated due to fractures after hip replacement in 2012–2018, 18 patients were separated out, aged over 85, out of whom 7 had type C fractures, according to the Vancouver classification. These seven patients formed the study group. The fractures were stabilized with a locking compression plate system and wire loops or by replacement of the endoprosthesis stem. The FEM was performed by processing radiological images of …

Elderly patientsPeriprosthetic fractureEndoprosthesisIn silicoHip arthroplastyFinite element model
researchProduct

Biomechanical analysis of the humeral tray positioning in reverse shoulder arthroplasty design

2017

Despite the widespread use of reverse total shoulder arthroplasty, the fundamental effects of implant configuration on certain biomechanical outcomes have not been completely elucidated especially for the most innovative prostheses. Aim of this work is to investigate the behaviour of a new reverse shoulder prosthesis, characterized by a humeral tray with a variable offset, designed to increase the range of motion and to reduce the impingement. The purposes of this study were to evaluate the effect of reverse shoulder implant design parameters on the deltoid muscle forces, required to produce abduction, and on the shoulder range of motion, in order to provide a more systematic understanding …

EngineeringOffset (computer science)medicine.medical_treatmentProsthesisIndustrial and Manufacturing Engineering03 medical and health sciences0302 clinical medicineDeltoid muscleVirtual prototypingmedicineCADReverse engineeringSettore ING-IND/15 - Disegno E Metodi Dell'Ingegneria IndustrialeReverse shoulder prosthesiFEM030222 orthopedicsbusiness.industryWork (physics)030229 sport sciencesArthroplastyFinite element methodTrayModeling and SimulationRange of motionbusinessBiomedical engineeringInternational Journal on Interactive Design and Manufacturing (IJIDeM)
researchProduct