Search results for "ARTICLES"
showing 10 items of 9626 documents
Single Event Transients and Pulse Quenching Effects in Bandgap Reference Topologies for Space Applications
2016
An architectural performance comparison of bandgap voltage reference variants, designed in a $0.18~\mu \text {m}$ CMOS process, is performed with respect to single event transients. These are commonly induced in microelectronics in the space radiation environment. Heavy ion tests (Silicon, Krypton, Xenon) are used to explore the analog single-event transients and have revealed pulse quenching mechanisms in analogue circuits. The different topologies are compared, in terms of cross-section, pulse duration and pulse amplitude. The measured results, and the explanations behind the findings, reveal important guidelines for designing analog integrated circuits, which are intended for space appli…
CNO and pep solar neutrino measurements and perspectives in Borexino
2015
International audience; The detection of neutrinos emitted in the CNO reactions in the Sun is one of the ambitious goals of Borexino Phase-II. A measurement of CNO neutrinos would be a milestone in astrophysics, and would allow to solve serious issues in current solar models. A precise measurement of the rate of neutrinos from the pep reaction would allow to investigate neutrino oscillations in the MSW transition region. The pep and CNO solar neutrino physics, the measurement in Borexino Phase-I and the perspectives for the new phase are reviewed in this proceeding.
Measurement of Solar pp-neutrino flux with Borexino: results and implications
2015
International audience; Measurement of the Solar pp-neutrino flux completed the measurement of Solar neutrino fluxes from the pp-chain of reactions in Borexino experiment. The result is in agreement with the prediction of the Standard Solar Model and the MSW/LMA oscillation scenario. A comparison of the total neutrino flux from the Sun with Solar luminosity in photons provides a test of the stability of the Sun on the 10(5) years time scale, and sets a strong limit on the power production by the unknown energy sources in the Sun.
Multi-resolution anisotropy studies of ultrahigh-energy cosmic rays detected at the Pierre Auger Observatory
2017
We report a multi-resolution search for anisotropies in the arrival directions of cosmic rays detected at the Pierre Auger Observatory with local zenith angles up to $80^\circ$ and energies in excess of 4 EeV ($4 \times 10^{18}$ eV). This search is conducted by measuring the angular power spectrum and performing a needlet wavelet analysis in two independent energy ranges. Both analyses are complementary since the angular power spectrum achieves a better performance in identifying large-scale patterns while the needlet wavelet analysis, considering the parameters used in this work, presents a higher efficiency in detecting smaller-scale anisotropies, potentially providing directional informa…
Enhanced pulmonary delivery of Salmeterol Xinafoate (SX) by mucoadhesive microparticles
2016
Excitation Transfer Engineering in Ce-Doped Oxide Crystalline Scintillators by Codoping with Alkali-Earth Ions
2018
This work has been supported by the European Social Fund Measure No. 09.3.3-LMT-K-712 activity Improvement of Researchers Qualification by Implementing the World-Class R&D Projects, and by grant #14.W03.31.0004 of the Russian Federation Government. Authors are grateful to CERN Crystal Clear Collaboration and COST Action TD1401 "Fast Advanced Scintillator Timing (FAST)" for support of collaboration.
Search for Electron Antineutrino Appearance in a Long-baseline Muon Antineutrino Beam
2020
Electron antineutrino appearance is measured by the T2K experiment in an accelerator-produced antineutrino beam, using additional neutrino beam operation to constrain parameters of the Pontecorvo-Maki-Nakagawa-Sakata (PMNS) mixing matrix. T2K observes 15 candidate electron antineutrino events with a background expectation of 9.3 events. Including information from the kinematic distribution of observed events, the hypothesis of no electron antineutrino appearance is disfavored with a significance of 2.40 σ and no discrepancy between data and PMNS predictions is found. A complementary analysis that introduces an additional free parameter which allows non-PMNS values of electron neutrino and a…
Design and implementation of the AMIGA embedded system for data acquisition
2021
The successful installation, commissioning, and operation of the Pierre Auger Observatory would not have been possible without the strong commitment and effort from the technical and admin-istrative staff in Malargtie. We are very grateful to the following agencies and organizations for financial support: Comision Nacional de Energla Atomica, Agencia Nacional de Promocion Cientffica y Tec-nologica (ANPCyT) , Consejo Nacional de Investigaciones Cientfficas y Tecnicas (CONICET) , Gobierno de la Provincia de Mendoza, Municipalidad de Malargtie, NDM Holdings and Valle Las Leilas, in gratitude for their continuing cooperation over land access, Argentina; the Australian Research Council; Conselho…
Calibration of the underground muon detector of the Pierre Auger Observatory
2021
To obtain direct measurements of the muon content of extensive air showers with energy above $10^{16.5}$ eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 $\mathrm{m^2}$-modules, each segmented into 64 scintillators coupled to silicon photomultipliers (SiPMs). Direct access to the shower muon content allows for the study of both of the composition of primary cosmic rays and of high-energy hadronic interactions in the forward direction. As the muon density can vary between tens of muons per m$^2$ close to the intersection of the shower axis with the ground to much less than one per m$^2$ when far away, the necessary bro…
Cardiolipin content controls mitochondrial coupling and energetic efficiency in muscle
2020
Decreasing mitochondrial energy-production efficiency in skeletal muscle can confer protection against diet-induced obesity.