Search results for "ASTIGMATISM"
showing 10 items of 91 documents
A genome-wide association study of corneal astigmatism: The CREAM Consortium
2018
Contains fulltext : 191261.pdf (Publisher’s version ) (Open Access) Purpose: To identify genes and genetic markers associated with corneal astigmatism. Methods: A meta-analysis of genome-wide association studies (GWASs) of corneal astigmatism undertaken for 14 European ancestry (n=22,250) and 8 Asian ancestry (n=9,120) cohorts was performed by the Consortium for Refractive Error and Myopia. Cases were defined as having >0.75 diopters of corneal astigmatism. Subsequent gene-based and gene-set analyses of the meta-analyzed results of European ancestry cohorts were performed using VEGAS2 and MAGMA software. Additionally, estimates of single nucleotide polymorphism (SNP)-based heritability for …
2019
Purpose Myopia is increasing worldwide and possibly linked to education. In this study, we analyse the association of myopia and education in the U.S. and investigate its age-dependency. Methods We conducted a secondary data analysis using the public use files from the cross-sectional study National Health and Nutrition Examination Survey of the period from 1999 to 2008. 19,756 participants aged 20 to 85 years were included with data on education and ophthalmic parameters (distance visual acuity, objective refraction and keratometry). Spherical equivalent, astigmatism, corneal power and corneal astigmatism were evaluated for an association with education using linear regression analysis wit…
Anisometropia of ocular refractive and biometric measures among 66- to 79-year-old female twins
2016
Purpose To examine the prevalence of anisometropia of spherical refraction (AnisoSR), astigmatism (AnisoAST) and spherical equivalent (AnisoSE) and their associations with spherical refraction (SR), refractive astigmatism (AST), spherical equivalent (SE) and interocular differences of ocular biometric parameters among elderly female twins. Methods Refraction of 117 monozygotic (MZ) and 116 dizygotic (DZ) female twin subjects aged 66–79 years was assessed with an auto-refractor (Topcon AT) and controlled by subjective refraction. Corneal refraction, anterior chamber depth and axial length were measured with a Zeiss IOL Master. Participants with eyes operated for cataract or glaucoma were exc…
Corneal and Refractive Astigmatism in Adults: A Power Vectors Analysis
2009
Purpose. In this article, we examine the relationship between corneal and refractive astigmatism (including with the rule, against-the-rule, and oblique astigmatism) in an adult population using power vectors. Methods. Refractive and keratometric measures of astigmatism were conducted on right eyes of 105 white subjects aged 18 to 59 years. We performed a linear regression of refractive astigmatic error on corneal astigmatism, using the J0 and J45 components of the astigmatism. Results. We obtained a statistically significant regression relationship between the corneal (C) and refractive (R) astigmatism for both J0 and J45 components, namely, RJ0 = 1.07 × CJ0 − 0.28; and RJ45 = 1.46 × CJ45 …
Contrast sensitivity and glare disability by halogen light after monofocal and multifocal lens implantation
2000
BACKGROUND—Standard examination of contrast sensitivity under conditions of glare disability is performed with incandescent light. A new halogen glare test that simulates glare as seen with oncoming vehicle headlights was used to measure glare disability in patients implanted with multifocal and monofocal intraocular lenses (IOLs). METHODS—28 patients with an average age of 69 years (SD 12 years) were implanted with a monofocal IOL (SI-40NB, Allergan) and 28 patients with an average of 66 years (12 years) were implanted with a refractive multifocal IOL (Array-SA-40N, Allergan). All patients were followed for 5 months postoperatively. Contrast sensitivity at four spatial frequencies (3, 6, 1…
Repeatability assessment of biometric measurements with different refractive states and age using a swept-source biometer
2018
Background We aim to assess if refractive error or age may influence the repeatability of measurements using a swept-source biometer. Methods A total of 61 subjects were evaluated with IOLMaster 700 acquiring measurements of axial length (AL), central corneal thickness (CCT), white-to-white distance (WTW), anterior aqueous depth (AQD), lens thickness (LT), and keratometry (K) readings. Repeatability was evaluated classifying the sample according to the refractive state and age by the calculation of the within-subject standard deviation (Sw), coefficient of repeatability, and intraclass correlation coefficient. Results Very similar Sw was acquired among groups for AL, CCT, and WTW. Differenc…
Distribution of Anterior Chamber Angle Width and Correlation With Age, Refraction, and Anterior Chamber Depth—The Gutenberg Health Study
2016
PURPOSE Scheimpflug imaging allows quantitative analysis of the width of the anterior chamber angle. We report the population-based distribution of the anterior chamber angle width using this noncontact imaging technique and investigate associated factors. METHODS A population-based cross-sectional study was carried out in Germany. A comprehensive ophthalmologic examination including refraction, biometry, and Scheimpflug imaging was performed. Automated measurement of the anterior chamber angle was performed in each anterior chamber quadrant. Exclusion criteria were previous ocular surgery or inadequate image quality. Association analyses were carried out to determine independently associat…
Intrasubject repeatability of corneal power, thickness, and wavefront aberrations with a new version of a dual rotating Scheimpflug–Placido system
2014
Purpose To determine the intrasubject repeatability of a recently introduced dual-camera rotating Scheimpflug–Placido imaging system (Galilei G4) in determining corneal thickness, power, and wavefront aberrations in young healthy subjects. Setting University of Valencia, Valencia, Spain. Design Prospective evaluation of diagnostic technology. Methods The study comprised right eyes of 25 subjects aged 20 to 40 years with a spherical equivalent ranging from −4.25 to +1.00 diopters. The central corneal thickness, thinnest point value and location, anterior and posterior surface curvatures, total corneal power, and corneal wavefront aberrations were measured for distance vision using the dual S…
The effect of aberrations on objectively assessed image quality and depth of focus
2017
The effects of aberrations on image quality and the objectively assessed depth of focus (DoF) were studied. Aberrometry data from 80 young subjects with a range of refractive errors was used for computing the visual Strehl ratio based on the optical transfer function (VSOTF), and then, through-focus simulations were performed in order to calculate the objective DoF (using two different relative thresholds of 50% and 80%; and two different pupil diameters) and the image quality (the peak VSOTF). Both lower order astigmatism and higher order aberration (HOA) terms up to the fifth radial order were considered. The results revealed that, of the HOAs, the comatic terms (third and fifth order) ex…
Corneoscleral contact lenses for visual rehabilitation after keratoplasty surgery.
2019
Abstract Purpose To report the use of corneoscleral lenses (CSL) in keratoconus patients who were unsatisfied with their visual outcomes after keratoplasty surgery. Methods Eleven consecutive cases with unsatisfactory vision with spectacles, due to irregular astigmatism, preferred to try CSL before SL due to handling or economic issues. An eye examination included refraction and visual acuity assessment, anterior eye biomicroscopy, ocular fundus examination, corneal topographic analysis, endothelial-cell count (ECC) and evaluation of corneal biomechanical parameters (corneal resistance factor, CRF; corneal hysteresis, CH; corneal-compensated intraocular pressure, IOPcc). The fitting process…