Search results for "ASTIGMATISM"
showing 10 items of 91 documents
A new approach based on Machine Learning for predicting corneal curvature (K1) and astigmatism in patients with keratoconus after intracorneal ring i…
2014
Keratoconus (KC) is the most common type of corneal ectasia. A corneal transplantation was the treatment of choice until the last decade. However, intra-corneal ring implantation has become more and more common, and it is commonly used to treat KC thus avoiding a corneal transplantation. This work proposes a new approach based on Machine Learning to predict the vision gain of KC patients after ring implantation. That vision gain is assessed by means of the corneal curvature and the astigmatism. Different models were proposed; the best results were achieved by an artificial neural network based on the Multilayer Perceptron. The error provided by the best model was 0.97D of corneal curvature …
Biaxial Microincision versus Coaxial Small-Incision Clear Cornea Cataract Surgery
2005
Objective To compare clinical outcomes of biaxial microincision (1.5 mm) and coaxial small-incision (2.75 mm) clear cornea cataract surgery. Design Randomized controlled clinical trial. Participants Seventy eyes of 70 patients were examined at a German university eye hospital. Intervention The 70 patients (70 eyes) were assigned randomly (1:1) to a biaxial or conventional coaxial incision group. Both groups underwent phacoemulsification using pulsed ultrasound energy with variable duty cycles, followed by microincision intraocular lens implantation. Main Outcome Measures Best-corrected visual acuity (BCVA), astigmatism, laser flare photometry value, effective phacoemulsification time (EPT),…
Prevalence of cataract after collagen copolymer phakic intraocular lens implantation for myopia, hyperopia, and astigmatism
2015
Purpose To evaluate the prevalence of cataract after Implantable Collamer Lens phakic intraocular lens (pIOL) implantation with different models at different ages and for different refractive powers. Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Retrospective nonrandomized clinical study. Methods The pIOL (models V4, V4b, or V4c) was implanted in all cases. Results The study included 3420 eyes (1898 patients). The mean patient age at surgery was 31.2 years ± 6.4 (SD) (range 18 to 50 years) and the mean spherical refractive error, −7.27 ± 5.24 diopters (D) (range −26.5 to 12.5 D). Twenty-one eyes (0.61%) of 15 patients had pIOL explantation (all model V4) because c…
Iris-fixated toric phakic intraocular lens for myopic astigmatism
2011
Purpose To evaluate the efficacy, predictability, safety, stability, and complications of the Artiflex toric iris-fixated phakic intraocular lens (pIOL) for myopic astigmatism. Setting Private practice surgery centers, Valencia and Terrassa, Spain. Design Cohort study. Methods At 12 months, refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, complications, pIOL misalignment, and endothelial cell count (ECC) were evaluated. Indices of success and misalignment were calculated using vector analysis. Results The study enrolled 42 eyes in 25 patients aged 21 to 39 years. The mean spherical equivalent decreased from −8.85 diopters (D) ± 2.71 (SD) to −0.37 ± 0.46 D, with …
An alternative clinical routine for subjective refraction based on power vectors with trial frames.
2016
PURPOSE Subjective refraction determines the final point of refractive error assessment in most clinical environments and its foundations have remained unchanged for decades. The purpose of this paper is to compare the results obtained when monocular subjective refraction is assessed in trial frames by a new clinical procedure based on a pure power vector interpretation with conventional clinical refraction procedures. METHODS An alternative clinical routine is described that uses power vector interpretation with implementation in trial frames. Refractive error is determined in terms of: (i) the spherical equivalent (M component), and (ii) a pair of Jackson Crossed Cylinder lenses oriented …
Postoperative astigmatism and rotational stability after Artisan toric phakic intraocular lens implantation
2003
Abstract Purpose To evaluate deviations in the axis (intended versus achieved) and postoperative astigmatism after implantation of an Artisan toric phakic intraocular lens (IOL). Setting University Eye Hospital, Mainz, Germany. Methods This prospective study comprised 29 eyes with high ametropia and astigmatism. All eyes had uneventful implantation of a toric phakic IOL through a superior scleral tunnel incision at 12 o’clock. After a minimum of 6 months, the uncorrected visual acuity (UCVA), best correct visual acuity, refraction, and astigmatism were analyzed in all eyes. A multivariate analysis of postoperative astigmatism was performed. Results After a follow-up of at least 6 months, 95…
Prevalence of corneal astigmatism before cataract surgery.
2008
To analyze the prevalence and presentation patterns of corneal astigmatism in cataract surgery candidates.University of Valencia, Valencia, Spain.Refractive and keratometric values were measured before surgery in patients having cataract extraction. Descriptive statistics of refractive and keratometric cylinder data were analyzed and correlated by age ranges.Refractive and keratometric data from 4,540 eyes of 2,415 patients (mean age 60.59 years +/- 9.87 [SD]; range 32 to 87 years) differed significantly when the patients were divided into 10-year subsets. There was a trend toward less negative corneal astigmatism values, except the steepest corneal radius and the J(45) vector component, in…
Characterization of the effect of intracorneal ring segment in corneal ectasia after laser refractive surgery
2018
Purpose: To evaluate the visual, refractive, topographic, pachymetric, and biomechanical outcomes after intracorneal ring segment implantation in corneas with post-LASIK ectasia. Methods: Retrospective longitudinal study enrolling 26 eyes of 22 patients with post-LASIK ectasia and undergoing intracorneal ring segment implantation (KeraRing®, Mediphacos) using a 60-kHz femtosecond laser (IntraLase®, IntraLase Corp.) for corneal tunnelization. Visual, refractive, anterior, and posterior corneal topographic (Pentacam HR, Oculus), pachymetric, and corneal biomechanical changes (Ocular response Analyzer, Reichert) were evaluated during a 12-month follow-up. Vector analysis of astigmatic changes …
Influence of different types of astigmatism on visual acuity
2016
[EN] Purpose To investigate the change in visual acuity (VA) produced by different types of astigmatism (on the basis of the refractive power and position of the principal meridians) on normal accommodating eyes. Methods The lens induced method was employed to simulate a set of 28 astigmatic blur conditions on different healthy emmetropic eyes. Additionally, 24 values of spherical defocus were also simulated on the same eyes for comparison. VA was measured in each case and the results, expressed in logMAR units, were represented against of the modulus of the dioptric power vector (blur strength). Results LogMAR VA varies in a linear fashion with increasing astigmatic blur, being the slope o…
Human eyes do not need monochromatic aberrations for dynamic accommodation
2017
Purpose To determine if human accommodation uses the eye's own monochromatic aberrations to track dynamic accommodative stimuli. Methods Wavefront aberrations were measured while subjects monocularly viewed a monochromatic Maltese cross moving sinusoidally around 2D of accommodative demand with 1D amplitude at 0.2 Hz. The amplitude and phase (delay) of the accommodation response were compared to the actual vergence of the stimulus to obtain gain and temporal phase, calculated from wavefront aberrations recorded over time during experimental trials. The tested conditions were as follows: Correction of all the subject's aberrations except defocus (C); Correction of all the subject's aberratio…