Search results for "ASTIGMATISM"

showing 10 items of 91 documents

A new approach based on Machine Learning for predicting corneal curvature (K1) and astigmatism in patients with keratoconus after intracorneal ring i…

2014

Keratoconus (KC) is the most common type of corneal ectasia. A corneal transplantation was the treatment of choice until the last decade. However, intra-corneal ring implantation has become more and more common, and it is commonly used to treat KC thus avoiding a corneal transplantation. This work proposes a new approach based on Machine Learning to predict the vision gain of KC patients after ring implantation. That vision gain is assessed by means of the corneal curvature and the astigmatism. Different models were proposed; the best results were achieved by an artificial neural network based on the Multilayer Perceptron. The error provided by the best model was 0.97D of corneal curvature …

AdultMaleKeratoconusgenetic structuresComputer sciencemedicine.medical_treatmentHealth InformaticsAstigmatismMachine learningcomputer.software_genreKeratoconusCorneal TransplantationMachine LearningYoung AdultCorneal ectasiaIntracorneal ringsArtificial IntelligenceProsthesis FittingmedicineHumansIn patientCorneal transplantationAgedRing (mathematics)Corneal curvaturebusiness.industryCorneal TopographyAstigmatismProstheses and ImplantsMiddle AgedDecision Support Systems ClinicalPrognosismedicine.diseaseeye diseasesComputer Science ApplicationsPatient Outcome AssessmentTreatment OutcomeFemalesense organsArtificial intelligencebusinesscomputerLENGUAJES Y SISTEMAS INFORMATICOSSoftware
researchProduct

Biaxial Microincision versus Coaxial Small-Incision Clear Cornea Cataract Surgery

2005

Objective To compare clinical outcomes of biaxial microincision (1.5 mm) and coaxial small-incision (2.75 mm) clear cornea cataract surgery. Design Randomized controlled clinical trial. Participants Seventy eyes of 70 patients were examined at a German university eye hospital. Intervention The 70 patients (70 eyes) were assigned randomly (1:1) to a biaxial or conventional coaxial incision group. Both groups underwent phacoemulsification using pulsed ultrasound energy with variable duty cycles, followed by microincision intraocular lens implantation. Main Outcome Measures Best-corrected visual acuity (BCVA), astigmatism, laser flare photometry value, effective phacoemulsification time (EPT),…

AdultMaleMicrosurgerymedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityCell CountIntraocular lensAstigmatismCorneaLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesDioptreAgedAged 80 and overPhacoemulsificationbusiness.industryEndothelium CornealAstigmatismPhacoemulsificationMiddle AgedCataract surgerymedicine.diseaseOphthalmologyFemalemedicine.symptomCoaxialbusinessSurgical incisionOphthalmology
researchProduct

Prevalence of cataract after collagen copolymer phakic intraocular lens implantation for myopia, hyperopia, and astigmatism

2015

Purpose To evaluate the prevalence of cataract after Implantable Collamer Lens phakic intraocular lens (pIOL) implantation with different models at different ages and for different refractive powers. Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Design Retrospective nonrandomized clinical study. Methods The pIOL (models V4, V4b, or V4c) was implanted in all cases. Results The study included 3420 eyes (1898 patients). The mean patient age at surgery was 31.2 years ± 6.4 (SD) (range 18 to 50 years) and the mean spherical refractive error, −7.27 ± 5.24 diopters (D) (range −26.5 to 12.5 D). Twenty-one eyes (0.61%) of 15 patients had pIOL explantation (all model V4) because c…

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyAdolescentgenetic structuresPolymersmedicine.medical_treatmentVisual AcuityAstigmatismMyopia/hyperopiaPhakic intraocular lensCataractLens Implantation IntraocularCataractsOlder patientsPatient ageOphthalmologyMyopiaPrevalencemedicineHumansDevice RemovalDioptreRetrospective Studiesbusiness.industryAstigmatismMiddle AgedCataract surgerymedicine.diseaseeye diseasesSensory SystemsOphthalmologyHyperopiaSpainFemaleSurgeryCollagensense organsbusinessFollow-Up StudiesJournal of Cataract and Refractive Surgery
researchProduct

Iris-fixated toric phakic intraocular lens for myopic astigmatism

2011

Purpose To evaluate the efficacy, predictability, safety, stability, and complications of the Artiflex toric iris-fixated phakic intraocular lens (pIOL) for myopic astigmatism. Setting Private practice surgery centers, Valencia and Terrassa, Spain. Design Cohort study. Methods At 12 months, refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, complications, pIOL misalignment, and endothelial cell count (ECC) were evaluated. Indices of success and misalignment were calculated using vector analysis. Results The study enrolled 42 eyes in 25 patients aged 21 to 39 years. The mean spherical equivalent decreased from −8.85 diopters (D) ± 2.71 (SD) to −0.37 ± 0.46 D, with …

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyVisual acuitygenetic structuresVisual AcuityIrisAstigmatismRefraction OcularPhakic intraocular lensCohort StudiesMyopic astigmatismYoung AdultPostoperative ComplicationsLens Implantation IntraocularOphthalmologyMyopiamedicineHumansIris (anatomy)Dioptremedicine.diagnostic_testbusiness.industrySuture TechniquesAstigmatismCorneal TopographyCorneal topographymedicine.diseaseeye diseasesSensory SystemsOphthalmologyTreatment Outcomemedicine.anatomical_structurePrivate practiceFemaleSurgerymedicine.symptombusinessFollow-Up StudiesJournal of Cataract and Refractive Surgery
researchProduct

An alternative clinical routine for subjective refraction based on power vectors with trial frames.

2016

PURPOSE Subjective refraction determines the final point of refractive error assessment in most clinical environments and its foundations have remained unchanged for decades. The purpose of this paper is to compare the results obtained when monocular subjective refraction is assessed in trial frames by a new clinical procedure based on a pure power vector interpretation with conventional clinical refraction procedures. METHODS An alternative clinical routine is described that uses power vector interpretation with implementation in trial frames. Refractive error is determined in terms of: (i) the spherical equivalent (M component), and (ii) a pair of Jackson Crossed Cylinder lenses oriented …

AdultMaleRefractive errorCorrelation coefficientAdolescentVisual AcuityAstigmatismRefraction Ocular01 natural sciences010309 optics03 medical and health sciencesYoung Adult0302 clinical medicineOptics0103 physical sciencesmedicineHumansPhoropterMathematicsMonocularbusiness.industryOrientation (computer vision)Vision TestsEquipment Designmedicine.diseaseRefractive ErrorsSubjective refractionRefractionSensory SystemsOphthalmologyEyeglasses030221 ophthalmology & optometryFemalebusinessAlgorithmOptometryOphthalmicphysiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)
researchProduct

Postoperative astigmatism and rotational stability after Artisan toric phakic intraocular lens implantation

2003

Abstract Purpose To evaluate deviations in the axis (intended versus achieved) and postoperative astigmatism after implantation of an Artisan toric phakic intraocular lens (IOL). Setting University Eye Hospital, Mainz, Germany. Methods This prospective study comprised 29 eyes with high ametropia and astigmatism. All eyes had uneventful implantation of a toric phakic IOL through a superior scleral tunnel incision at 12 o’clock. After a minimum of 6 months, the uncorrected visual acuity (UCVA), best correct visual acuity, refraction, and astigmatism were analyzed in all eyes. A multivariate analysis of postoperative astigmatism was performed. Results After a follow-up of at least 6 months, 95…

AdultMaleRefractive errorVisual acuityRotationgenetic structuresmedicine.medical_treatmentEmmetropiaIntraocular lensPhakic intraocular lensLens Implantation IntraocularmedicineHumansPostoperative PeriodProspective StudiesDioptreLenses Intraocularbusiness.industryAstigmatismEquipment DesignMiddle AgedRefractive Errorsmedicine.diseaseeye diseasesSensory SystemsRefractive Surgical ProceduresToric lensOphthalmologyMeridian (perimetry visual field)OptometryFemaleSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Prevalence of corneal astigmatism before cataract surgery.

2008

To analyze the prevalence and presentation patterns of corneal astigmatism in cataract surgery candidates.University of Valencia, Valencia, Spain.Refractive and keratometric values were measured before surgery in patients having cataract extraction. Descriptive statistics of refractive and keratometric cylinder data were analyzed and correlated by age ranges.Refractive and keratometric data from 4,540 eyes of 2,415 patients (mean age 60.59 years +/- 9.87 [SD]; range 32 to 87 years) differed significantly when the patients were divided into 10-year subsets. There was a trend toward less negative corneal astigmatism values, except the steepest corneal radius and the J(45) vector component, in…

AdultMaleRefractive errormedicine.medical_specialtygenetic structuresmedicine.medical_treatmentEye diseaseIntraocular lensCataract ExtractionAstigmatismCorneal DiseasesVision disorderAge DistributionCorneaOphthalmologymedicinePrevalenceHumansProspective StudiesAgedAged 80 and overbusiness.industryAstigmatismCataract surgeryMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologymedicine.anatomical_structureSpainOptometrySurgeryFemalesense organsmedicine.symptombusinessCorneal astigmatismJournal of cataract and refractive surgery
researchProduct

Characterization of the effect of intracorneal ring segment in corneal ectasia after laser refractive surgery

2018

Purpose: To evaluate the visual, refractive, topographic, pachymetric, and biomechanical outcomes after intracorneal ring segment implantation in corneas with post-LASIK ectasia. Methods: Retrospective longitudinal study enrolling 26 eyes of 22 patients with post-LASIK ectasia and undergoing intracorneal ring segment implantation (KeraRing®, Mediphacos) using a 60-kHz femtosecond laser (IntraLase®, IntraLase Corp.) for corneal tunnelization. Visual, refractive, anterior, and posterior corneal topographic (Pentacam HR, Oculus), pachymetric, and corneal biomechanical changes (Ocular response Analyzer, Reichert) were evaluated during a 12-month follow-up. Vector analysis of astigmatic changes …

AdultMaleReoperationmedicine.medical_specialtyCorneal ectasiagenetic structuresCorneal Surgery Lasermedicine.medical_treatmentVisual AcuityAstigmatismProsthesis DesignRefraction OcularCorneal Diseaseslaw.inventionCorneaCorneal ectasiaPostoperative ComplicationsLens Implantation IntraocularlawIntracorneal ring segmentEctasiaOphthalmologyRefractive surgerymedicineHumansPost-LASIK ectasiaPentacam hrIntracorneal ring segmentRetrospective StudiesÓpticaPost-LASIK ectasiabusiness.industryCorneal TopographyGeneral MedicineMiddle Agedmedicine.diseaseLasereye diseasesOphthalmologyFemalesense organsbusinessDilatation PathologicFollow-Up StudiesEuropean Journal of Ophthalmology
researchProduct

Influence of different types of astigmatism on visual acuity

2016

[EN] Purpose To investigate the change in visual acuity (VA) produced by different types of astigmatism (on the basis of the refractive power and position of the principal meridians) on normal accommodating eyes. Methods The lens induced method was employed to simulate a set of 28 astigmatic blur conditions on different healthy emmetropic eyes. Additionally, 24 values of spherical defocus were also simulated on the same eyes for comparison. VA was measured in each case and the results, expressed in logMAR units, were represented against of the modulus of the dioptric power vector (blur strength). Results LogMAR VA varies in a linear fashion with increasing astigmatic blur, being the slope o…

AdultMaleVisual acuityVisual acuityAstigmatismoEstado de acomodaciónAstigmatismAgudeza visual03 medical and health sciences0302 clinical medicinelcsh:Ophthalmologymedicinelcsh:QC350-467HumansAgudeza visualAccommodation OcularAstigmatismmedicine.diseaseEyeglassesReadingEjelcsh:RE1-994Defecto esféricoFISICA APLICADA030221 ophthalmology & optometryOptometryAccommodation stateOriginal ArticleFemalemedicine.symptomSpherical defocusAxisPsychologylcsh:Optics. Light030217 neurology & neurosurgeryOptometry
researchProduct

Human eyes do not need monochromatic aberrations for dynamic accommodation

2017

Purpose To determine if human accommodation uses the eye's own monochromatic aberrations to track dynamic accommodative stimuli. Methods Wavefront aberrations were measured while subjects monocularly viewed a monochromatic Maltese cross moving sinusoidally around 2D of accommodative demand with 1D amplitude at 0.2 Hz. The amplitude and phase (delay) of the accommodation response were compared to the actual vergence of the stimulus to obtain gain and temporal phase, calculated from wavefront aberrations recorded over time during experimental trials. The tested conditions were as follows: Correction of all the subject's aberrations except defocus (C); Correction of all the subject's aberratio…

AdultMaledirectional cuesgenetic structuresVisual AcuityRefraction Ocular01 natural sciencesdynamic accommodation010309 opticsYoung Adult03 medical and health sciences0302 clinical medicineOpticsmonochromatic aberrations0103 physical sciencesHumansWavefrontPhysicsdefocusbusiness.industryAccommodation OcularAstigmatismOriginal ArticlesConvergence Oculareye diseasesSensory SystemsOphthalmologySpherical aberrationAmplitude030221 ophthalmology & optometryFemaleOriginal Articlesense organsMonochromatic colorbusinessAccommodationPhotic StimulationOptometryOphthalmic and Physiological Optics
researchProduct