The effect of spherical aberration on visual performance and refractive state for stimuli and tasks typical of night viewing

2018

Purpose: The aim of this work was to examine the impact of Seidel spherical aberration (SA) on optimum refractive state for detecting and discriminating small bright lights on a dark background. Methods: An adaptive-optics system was used to correct ocular aberrations of cyclopleged eyes and then systematically introduce five levels of Seidel SA for a 7-mm diameter pupil: 0, ± 0.18, and ± 0.36 diopters (D) mm−2. For each level of SA, subjects were required to detect one or resolve two points of light (0.54 arc min diameter) on a dark background. Refractive error was measured by adjusting stimulus vergence to minimize detection and resolution thresholds. Two other novel focusing tasks for si…

AdultOptics and PhotonicsOriginal articleCorneal Wavefront AberrationVisual AcuityStarburstDiameter pupilRefraction Ocular050105 experimental psychology03 medical and health sciences0302 clinical medicinelcsh:OphthalmologyError refractivoVisión nocturnaAberración esféricalcsh:QC350-467Humans0501 psychology and cognitive sciencesSpherical aberrationNight visionPhysicsResoluciónRefractive error05 social sciencesMiddle AgedRefractive ErrorsDetecciónDetectionlcsh:RE1-994030221 ophthalmology & optometryResolutionHumanitieslcsh:Optics. LightPhotic StimulationOptometryJournal of Optometry
researchProduct

Changes of the eye optics after iris constriction☆

2010

Purpose: To evaluate the possible change in the optics of the human eye after iris constriction. Methods: Ocular aberrations were measured under natural viewing conditions in 26 eyes. The measured eyes fixated on a dim target while the contralateral eye was either occluded (so the measured eye had a large pupil) or highly illuminated (so the measured eye had a small pupil). The measured eyes fixated to a dim target placed 0.5 D beyond the subject’s far point. Zernike values obtained in both situations were compared within the same pupil diameter corresponding to the one obtained under the high illumination condition. Results: Significant variation in some aberration coefficients were found …

genetic structuresComputer scienceIrisAberraciones ocularesOcular aberrationsConstrictionOpticslcsh:OphthalmologyAberración esféricamedicinelcsh:QC350-467Spherical aberrationÓptica del ojoIris (anatomy)skin and connective tissue diseasesurogenital systembusiness.industryeye diseasesSpherical aberrationmedicine.anatomical_structurelcsh:RE1-994Eye opticsHuman eyeOriginal Articlesense organsbusinesslcsh:Optics. LightOptometry
researchProduct

Interocular differences in visual quality due to ocular aberrations and scattering in a patient with post-traumatic anisocoria: A case report

2012

AbstractA 41-year-old patient with visual disturbances after an ocular trauma in right eye three years before was carefully analyzed and discussed. No corneal or intraocular sequelae were present. Only a significant anisocoria could be observed. Right eye (RE) achieved a best spectacle-corrected visual acuity (BSCVA) of 0.05 LogMAR with a refraction of +0.50 sphere and −1.25 cylinder. Left eye (LE) achieved a BSCVA of 0.0 LogMAR with a refraction of +0.75 sphere and −1.00 cylinder. In photopic conditions pupil diameter was 4.96mm for RE and 3.02mm for LE whereas in scotopic conditions, these values were 7.45mm and 6.71mm, respectively. More significant levels of higher-order corneal and ocu…

medicine.medical_specialtyVisual acuitygenetic structuresCase ReportPupilScatteringlcsh:OphthalmologyOphthalmologymedicinelcsh:QC350-467AberraciónScotopic visionPupilaAnisocoriabusiness.industryFunción de dispersión del puntoPupil sizePupilRefractionAnisocoriaPoint spread functioneye diseasesDispersiónlcsh:RE1-994Visual DisturbanceOptometrysense organsmedicine.symptombusinessAberrationlcsh:Optics. LightPhotopic visionOptometryJournal of Optometry