Search results for "Aberrations"

showing 10 items of 192 documents

A pilot study on the differences in wavefront aberrations between two ethnic groups of young generally myopic subjects

2008

A comparative population-based cross-sectional study design was used to examine the prevalence of wavefront patterns in two different ethnic groups, and the relationship of these patterns with ocular biometrics and gender. The Shin–Nippon SRW5000 open field autorefractor, the Wavefront Analysis Supported Customized Ablation (WASCA) wavefront analyser and the IOLMaster were used to determine wavefront aberrations, mean spherical equivalent (SE) refractive error and axial length (AL). Seventy-four eyes from 74 young healthy subjects (44 British Asians, 30 Caucasians; 36 men, 38 women; mean age 22.51 ± 3.89 years) with mean SE averaging )1.90 ± 2.76 D (range )10.88 to +2.19 D) were examined. R…

WavefrontRefractive erroreducation.field_of_studyPopulationComa (optics)medicine.diseaseSensory SystemsPearson product-moment correlation coefficient03 medical and health sciencesOphthalmologysymbols.namesakeAberrations of the eye0302 clinical medicineAutorefractorStatisticsLinear regression030221 ophthalmology & optometrymedicinesymbolsOptometryeducation030217 neurology & neurosurgeryOptometryMathematicsOphthalmic and Physiological Optics
researchProduct

Depth-of-Field of the Accommodating Eye

2014

Our eyes project information from a three-dimensional world to a basically two-dimensional surface, corresponding to the photoreceptor plane in the retina. In theory, only one plane or surface of world can be in focus at one time. However, the eye exhibits a certain tolerance to out-of-focus images, a feature that is known as depth-of-focus (DOF). The corresponding distance range in which the objects are seen “clearly” is known as depth-of-field (DOFi). Although DOF and DOFi refer to an interval of distances or a dioptric range in the image and object space, respectively, both parameters define a similar concept and are usually interchangeable. This article will mainly refer to DOFi because…

accommodationAdultMaleCorneal Wavefront Aberrationdepth-of-fieldComputer scienceaccommodative lagRefraction OcularLegibilityadaptive opticsYoung AdultPsychometric functionHumansComputer visionDepth of fieldaccommodation responseDioptreWavefrontDepth Perceptiondepth-of-focusbusiness.industryAccommodation OcularPupilOriginal ArticlesOphthalmologyFar pointaberrationsFemaleArtificial intelligencespherical aberrationDepth perceptionbusinessAccommodationOptometryOptometry and Vision Science
researchProduct

Crystalline lens response to different optical signals

2016

Es bien sabido que el ojo es capaz de cambiar su potencia con el fin de enfocar a objetos ubicados a diferentes distancias. El cambio en enfoque del ojo humano se denomina acomodación y es vital para el rendimiento visual del mismo ya que la acomodación tiene una contribución esencial para dicho rendimiento. La calidad de la imagen retiniana también influye en el rendimiento visual del ojo humano así como en la resolución de las imágenes formadas en la retina. La calidad de la imagen retiniana se describe en términos de aberraciones oculares. El objetivo de esta Tesis fue investigar la respuesta del cristalino a diferentes señales ópticas. Para lograr el objetivo del estudio se utilizaron l…

accommodationUNESCO::CIENCIAS DE LA VIDAocular aberrations:CIENCIAS DE LA VIDA [UNESCO]adaptive optics
researchProduct

Light vergence detection in monocular and monochromatic accommodation

2017

El ojo proyecta información desde el mundo tridimensional a la retina, la cual es una superficie bidimensional. Por este motivo, teóricamente sólo objetos que se encuentren en el plano conjugado a la retina pueden ser enfocados de forma correcta y, por tanto, objetos que se encuentren por delante o por detrás del plano conjugado, serán percibidos como imágenes borrosas. Por suerte, la acomodación ocular permite al ojo joven ver objetos situados a diferentes distancias de forma nítida. Este sistema de autoenfoque se consigue gracias al cambio de potencia dióptrica experimentado por el ojo como consecuencia del cambio en la morfología del cristalino. Debido a la alta frecuencia temporal de la…

accommodationUNESCO::FÍSICA::Óptica:FÍSICA::Óptica [UNESCO]aberrationslight vergencetrial and errordynamic accommodationcues for accommodationadaptive optics
researchProduct

Ortokeratoloģijas lēcas dizaina ietekme uz acs aksiālā garuma izmaiņām.

2020

Maģistra darbs ir uzrakstīts angļu valodā uz 59 lapaspusēm. Tas satur 24 attēlus, 3 tabulas un 85 literatūras atsauces. Pētījuma mērķis bija novērtēt miopijas kontroles ortokeratoloģijas lēcu formas un optiskās zonas platuma ietekmi uz miopijas progresijas mazināšanu. Darbā tika analizēti 12 bērnu ar augstu miopijas pakāpi ortokeratoloģijas rezultāti, iegūti kopā no 19 acīm. Tika salīdzinātas acs aksiālā garuma izmaiņas, bērniem nēsājot parastas ortokeratoloģijas lēcas un lietojot specializētās miopijas kontroles ortokeratoloģijas lēcas. Rezultāti parādīja, ka specializētās ortokerotoloģijas lēcas daudz efektīvāk samazina acs aksiālā garuma palielināšanos nekā parastās lēcas. Atslēgas vārdi…

after orthokeratology corneal topographysurface corneal aberrationsmyopia control lensesFizikacustom orthokeratology lenses
researchProduct

Genetic and Molecular Characterization of The Human Osteosarcoma 3AB-OS Cancer Stem Cell Line: A Possible Model For Studying Osteosarcoma Origin and …

2013

Finding new treatments targeting cancer stem cells (CSCs) within a tumor seems to be critical to halt cancer and improve patient survival. Osteosarcoma is an aggressive tumor affecting adolescents, for which there is no second-line chemotherapy. Uncovering new molecular mechanisms underlying the development of osteosarcoma and origin of CSCs is crucial to identify new possible therapeutic strategies. Here, we aimed to characterize genetically and molecularly the human osteosarcoma 3AB-OS CSC line, previously selected from MG63 cells and which proved to have both in vitro and in vivo features of CSCs. Classic cytogenetic studies demonstrated that 3AB-OS cells have hypertriploid karyotype wit…

cancer stem cellsPhysiologyClinical Biochemistrymedicine.disease_causePolymerase Chain ReactionOsteosarcoma cancer stem cellSettore BIO/10 - BiochimicaChromosomes HumanGene Regulatory NetworksCopy-number variationOligonucleotide Array Sequence AnalysisGeneticsComparative Genomic HybridizationOsteosarcomabiologychromosomal aberrationGene Expression Regulation NeoplasticPhenotypemiRNAsNeoplastic Stem CellsOsteosarcomaMitosisBone NeoplasmsHMGA2Cancer stem cellCell Line TumormicroRNABiomarkers Tumorgene expression profilingmedicineHumansOsteosarcoma cancer stem cells; karyotype; chromosomal aberrations; gene expression profiling; miRNAsCell LineageGenetic Predisposition to DiseaseRNA MessengerCell NucleusChromosome AberrationsPloidiesModels GeneticComputational BiologyCancerCell Biologymedicine.diseasekaryotypeMicroRNAsKaryotypingbiology.proteinCancer researchCarcinogenesisComparative genomic hybridization
researchProduct

Langer-Giedion syndrome with interstitial 8q-deletion.

1982

We describe a 12-year-old girl with Langer-Giedion syndrome (tricho-rhino-phalangeal syndrome type II) who also had vertebral malformations. Chromosome analysis identified an interstitial del(8q): 46,XX,del(8)(pter leads to q22::q234 leads to qter) as a cause of this syndrome.

congenital hereditary and neonatal diseases and abnormalitiesmedicine.medical_specialtyChromosome DisordersNoseBone and BonesLanger–Giedion syndromeFingersChromosome analysisInternal medicineIntellectual Disabilityotorhinolaryngologic diseasesMedicineHumansAbnormalities MultipleChildGenetics (clinical)Chromosome AberrationsChromosomes Human 6-12 and XSyndrome typebusiness.industryAnatomySyndromemedicine.diseaseSpineChromosome BandingEndocrinologyKaryotypingFemaleChromosome DeletionbusinessAmerican journal of medical genetics
researchProduct

Ortokeratoloģijas ietekme uz ceturtās kārtas aberācijām.

2020

Maģistra darbs ir uzrakstīts angļu valodā uz 36 lapaspusēm. Tas satur 7 attēlus, 7 formulas, 7 tabulas, 3 grafikus un 38 literatūras atsauces. Darba mērķis bija novērtēt radzenes sagitālā augstuma un leņķa, kā arī ceturtās kārtas aberāciju izmaiņas pēc ortokeratoloģijas lēcu lietošanas. Pētījumā tika analizēti radzenes topogrāfijas dati, iegūti no 30 acīm, trīs mēnešus lietojot ortokeratoloģijas lēcas. Rezultāti neuzrādīja būtiskas izmaiņas ceturtās kārtas aberāciju lielumos. Modificējot ortokeratoloģijas lēcu parametrus, ir iespējams saglabāt labu redzes asumu un skotopisko redzi pēc ortokeratoloģijas lēcu lietošanas.

contact lenses with inverse geometryIV order aberrationsvisual acuityBaker’s FormulaorthokeratologyFizika
researchProduct

Acs optiskās kvalitātes ietekme uz kontrastjutību un redzes asumu

2017

Darbs ir uzrakstīts angļu valodā uz 50 lapaspusēm, satur 37 figūras, 1 tabula un 41 literatūras avotus. Pētījuma mērķis bija novērtēt redzes kvalitāti dalībniekiem ar dažādām izmaiņām acs optiskajās vidēs. Augsta kontrasta redzes asums, mezopiskais redzes asums un kontrastjutība ir labi parametri acs optiskās kvalitātes novērtēšanai. Mezopiskais redzes asums ir ar augstu jutību, lai atklātu dalībniekus ar nelielas pakāpes apduļķojumiem acs optiskajās vidēs (agrīna katarakta). Kontrastjutības tests ir jutīgs uz izmaiņām acs optiskajās vidēs dalībniekiem ar ortokeratoloģijas lēcām. Augsta kontrasta redzes asums ir pietiekami jutīgs uz cita veida izmaiņām acs struktūrās

contrast sensitivitydisability glarevisual acuityhigher order aberrationsOptometrijamesopic visual acuity
researchProduct

Koriģētais redzes asums, kontrastjutība un aberācijas keratokonusa pacientiem atkarībā no virsotnes atrašanās vietas

2018

Promocijas darbs ir uzrakstīts angļu valodā uz 29 lappusēm. Tajā ir 17 attēli, 2 tabulas un 26 atsauces. Mērķis. Novērtēt keratokonusa virsotnes radītās izmaiņas redzes asumā, kontrastjutībā un aberācijās. Metode. Noteikts redzes asums un kontrastjutība piecās dažādās frekvencēs ar FrACT programmu, lietojot briļļu un kontaktlēcu korekciju. Noteikts zīlītes diametra mērījums un topogrāfiskā karte ar Keratronu un Optikon. Rezultāti. Salīdzinot pacientus ar keratokonusa virsotni centrā un perifērijā, redzes asums ir statistiski nozīmīgi lielāks pacientiem ar keratokonusa virsotni centrā ar alfa=10% līmeni. Kontrastjutība ir statistiski nozīmīgi atšķirīga pacientiem, kuri lieto brilles un cietā…

contrast sensitivityvisual acuityapex position of the conuskeratoconusaberrationsOptometrija
researchProduct