Search results for "Aberrometry"

showing 6 items of 26 documents

Implantable collamer lens and femtosecond laser for myopia: comparison using an adaptive optics visual simulator.

2014

Purpose: To compare optical and visual quality of implantable collamer lens (ICL) implantation and femtosecond laser in situ keratomileusis (F-LASIK) for myopia. Methods: The CRX1 adaptive optics visual simulator (Imagine Eyes, Orsay, France) was used to simulate the wavefront aberration pattern after the two surgical procedures for -3-diopter (D) and -6-D myopia. Visual acuity at different contrasts and contrast sensitivities at 10, 20, and 25 cycles/degree (cpd) were measured for 3-mm and 5-mm pupils. The modulation transfer function (MTF) and point spread function (PSF) were calculated for 5-mm pupils. Results: F-LASIK MTF was worse than ICL MTF, which was close to diffraction-limited MT…

Point spread functionAdultLaser de excimerPhakic Intraocular LensesVisual acuityVisual acuitymedicine.medical_treatmentKeratomileusis Laser In SituLentes intraoculares; Sensibilidade de contrasteVisual AcuityCeratomileuse assistida por excimer laser in situ/métodosKeratomileusisPhakic intraocular lensMyopia/surgeryPupilKeratomileusis laser in situ/methodsContrast SensitivityYoung Adultlcsh:OphthalmologyLens Implantation IntraocularOptical transfer functionmedicineMyopiaHumansComputer SimulationContrast sensitivityAdaptive opticsSimulationPhysicsLasers excimer/therapeutic useAcuidade visualAberrometryAccommodation OcularGeneral MedicineOphthalmologyTreatment Outcomelcsh:RE1-994Lenses intraocularMiopia/cirurgiaOptometrySpatial frequencymedicine.symptomArquivos brasileiros de oftalmologia
researchProduct

Myopic astigmatism correction: comparison of a Toric Implantable Collamer Lens and a bioptics technique by an adaptive optics visual simulator.

2013

Purpose To compare the optical and visual quality of a simulated Toric Implantable Collamer Lens (TICL) and a bioptics technique to treat high myopic astigmatism. Methods An adaptive optics visual simulator was used to simulate the vision after TICL implantation and a bioptics procedure from the wavefront aberration pattern for moderate and high-myopic astigmatism. Visual acuity (VA) at different contrasts and contrast sensitivity (CS) at 10, 20 and 25 cycles degree−1 were measured for 3 and 5-mm pupils. Modulation Transfer Function (MTF) and Point Spread Function (PSF) were calculated for a 5-mm pupil. Results At a 3-mm pupil we only found statistically significant differences in VA betwee…

Point spread functionAdultMalePhakic Intraocular LensesVisual acuityCorneal Wavefront AberrationAdolescentVisual AcuityAstigmatismPupilContrast SensitivityYoung AdultBioptics (surgery)Lens Implantation IntraocularOptical transfer functionmedicineMyopiaHumansAdaptive opticsSimulationMathematicsAberrometryAstigmatismmedicine.diseaseSensory SystemsOphthalmologyFemaleSpatial frequencymedicine.symptomOptometryOphthalmicphysiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)
researchProduct

Optical Characterization Method for Tilted or Decentered Intraocular Lenses

2016

Purpose To test and validate a method for measuring the optical quality and optical power of monofocal intraocular lenses (IOLs) in the presence of a tilt or a decentration as well as its optical power. Methods The experimental system consists of an artificial eye (wet-cell) and a commercial aberrometer with a Shack-Hartmann sensor. Optical image quality parameters such as point spread function (PSF), modulation transfer function (MTF), and the simulations of the retinal image of an extended object are computed from the in vitro wavefront data of an IOL. Repeatability and reproducibility of the system are tested. Mathematical and ray-tracing simulations are used to ascertain the precision a…

Point spread functionOptics and PhotonicsAccuracy and precisionMaterials sciencePseudophakiaOptical powerArtificial Lens Implant Migration01 natural sciences010309 optics03 medical and health sciences0302 clinical medicineOpticsLens Implantation IntraocularOptical transfer function0103 physical sciencesHumansLenses IntraocularWavefrontReproducibilitybusiness.industryAberrometryReproducibility of ResultsRepeatabilityModels TheoreticalOphthalmologyTilt (optics)030221 ophthalmology & optometrybusinessOptometryOptometry and Vision Science
researchProduct

Wavefront Recovery: Shack-Hartmann Aberrometry vs PhaseLift Using a Single Binary Amplitude Modulating Mask

2019

We investigate whether a wavefront can be recovered by using a single mask rotated in four different positions. Results show that PhaseLift can recover the wavefront from intensity measurements using such a kind of modulation.

Point spread functionWavefrontPhysicsInterferometryAmplitudeOpticsModulationbusiness.industryAberrometrySpatial frequencybusinessIntensity (physics)Imaging and Applied Optics 2019 (COSI, IS, MATH, pcAOP)
researchProduct

Trifocal toric intraocular lenses in eyes with low amount of corneal astigmatism.

2020

Aim To evaluate the refractive and visual outcomes following cataract surgery and implantation of a trifocal toric intraocular lens (IOL) in eyes with low degrees of corneal astigmatism. Methods Twenty-six eyes of 22 patients who underwent implantation a trifocal toric IOL (FineVision PODFT, PhysIOL s.a., Liege, Belgium) were enrolled. Phacoemulsification with femtosecond laser, capsular tension ring insertion and intraoperative aberrometry were performed in all cases. All IOLs used showed a cylinder power of 1.00 D. Main outcome measures were refractive error and corrected-distance visual acuity (CDVA) and uncorrected-distance visual acuity (UDVA) values. Eyes were evaluated at 4mo post-su…

Refractive errormedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentintraocular lensIntraocular lensAstigmatismtoriclcsh:OphthalmologyClinical ResearchOphthalmologyAberrometrymedicinetrifocalbusiness.industryPhacoemulsificationCataract surgerymedicine.diseaseeye diseasesOphthalmologyastigmatismcataractlcsh:RE1-994phacoemulsificationsense organsmedicine.symptombusinessCorneal astigmatismInternational journal of ophthalmology
researchProduct

In vitro optical performance of nonrotational symmetric and refractive-diffractive aspheric multifocal intraocular lenses: impact of tilt and decentr…

2012

Purpose To evaluate the optical quality of Acrysof Restor SN6AD1 refractive–diffractive +3.00 D and Lentis Mplus LS-312 nonrotational symmetric +3.00 D aspheric multifocal intraocular lenses (IOLs) and analyze the effect of tilt and decentration. Setting University of Valencia, Valencia, and University of Murcia, Murcia, Spain. Design Experimental study. Methods An artificial model eye was used to measure wavefront aberrations of both IOL models. The modulation transfer function (MTF) and point-spread function (PSF) were calculated for a 5.0 mm pupil and under 5 situations: centered, 0.2 mm and 0.4 mm decentered, and 2 degrees and 4 degrees tilted. Results The refractive–diffractive IOL had…

WavefrontPhysicsLenses IntraocularOptics and Photonicsbusiness.industryAberrometryMultifocal intraocular lensModels TheoreticalArtificial Lens Implant MigrationProsthesis DesignRefraction OcularRefractionSensory SystemsCycles per degreeOphthalmologyOpticsTilt (optics)Optical transfer functionAberrometryOptometryHumansSurgerySpatial frequencybusinessJournal of cataract and refractive surgery
researchProduct