Influence of radiation defects on tritium release parameters from Li2O
1998
Abstract The study of the influence of radiation defects on tritium release behavior from polycrystalline Li2O was performed by simultaneous measurements of the luminescence emission and tritium release. It was found that the radiation defects in Li2O introduced by electron irradiation cause the retention of tritium. It is thought that the tritium recovery is affected by the formation of a Li–T bond, which is tolerant of high temperatures. The retardation of tritium decreases with increasing absorbed dose in the dose range from 50 to 140 MGy. The aggregation of radiation defects at high irradiation doses is considered to be responsible for the decrease of the interaction of tritium with rad…
Dose calculation in biological samples in a mixed neutron-gamma field at the TRIGA reactor of the University of Mainz
2010
To establish Boron Neutron Capture Therapy (BNCT) for non-resectable liver metastases and for in vitro experiments at the TRIGA Mark II reactor at the University of Mainz, Germany, it is necessary to have a reliable dose monitoring system. The in vitro experiments are used to determine the relative biological effectiveness (RBE) of liver and cancer cells in our mixed neutron and gamma fi eld. We work with alanine detectors in combination with Monte Carlo simulations, where we can measure and characterize the dose. To verify our calculations we perform neutron fl ux measurements using gold foil activation and pin-diodes . Material and methods . When L- α -alanine is irradiated with ionizing …
EPR DOSIMETRY IN A MIXED NEUTRON AND GAMMA RADIATION FIELD
2004
Suitability of Electron Paramagnetic Resonance (EPR) spectroscopy for criticality dosimetry was evaluated for tooth enamel, mannose and alanine pellets during the 'international intercomparison of criticality dosimetry techniques' at the SILENE reactor held in Valduc in June 2002, France. These three materials were irradiated in neutron and gamma-ray fields of various relative intensities and spectral distributions in order to evaluate their neutron sensitivity. The neutron response was found to be around 10% for tooth enamel, 45% for mannose and between 40 and 90% for alanine pellets according their type. According to the IAEA recommendations on the early estimate of criticality accident a…
Biodistribution and post-therapy dosimetric analysis of [177Lu]Lu-DOTAZOL in patients with osteoblastic metastases: first results
2019
Abstract Background Preclinical biodistribution and dosimetric analysis of [177Lu]Lu-DOTAZOL suggest the bisphosphonate zoledronate as a promising new radiopharmaceutical for therapy of bone metastases. We evaluated biodistribution and normal organ absorbed doses resulting from therapeutic doses of [177Lu]Lu-DOTAZOL in patients with metastatic skeletal disease. Method Four patients with metastatic skeletal disease (age range, 64–83 years) secondary to metastatic castration-resistant prostate carcinoma or bronchial carcinoma were treated with a mean dose of 5968 ± 64 MBq (161.3 mCi) of [177Lu]Lu-DOTAZOL. Biodistribution was assessed with serial planar whole body scintigraphy at 20 min and 3,…
Study of CT/MRI mutual information based registration applied in brachytherapy
2016
The present work aims to include magnetic resonance imaging (MRI) in a Medical Image-based Graphical platfOrm - Brachytherapy module (AMIGOBrachy) which coupled to the Monte Carlo N-Particle (MCNP6) code allows absorbed dose calculations. Computed tomography (CT) and MRI images were registered using mutual information algorithms to improve tissue segmentation potentially leading to a more accurate treatment planning system.
Impact of the Tiloop Bra mesh in CT images and dose delivery in breast radiotherapy
2012
A new titanized breast mesh, TiLOOP Bra, is currently available for implantation in patients who require radiotherapy. The purpose of this work is to study the dosimetric effect of the presence of a TiLOOP Bra mesh on breast radiation treatment and radiographic imaging. The dosimetric effects have been measured for three X‐ray energies: 1.25 MeV, 6 MV and 18 MV, using radiochromic films placed at three different depths. These depths are representative of mesh location in breast during the radiotherapy treatment and hence, are of interest in this study. In order to assess the disturbance in a radiographic image, different computed tomographic (CT) studies of the mesh have been performed. The…
2014
Background and purpose: A substantial reduction of uncertainties in clinical brachytherapy should result in improved outcome in terms of increased local control and reduced side effects. Types of uncertainties have to be identified, grouped, and quantified. Methods: A detailed literature review was performed to identify uncertainty components and their relative importance to the combined overall uncertainty. Results: Very few components (e.g., source strength and afterloader timer) are independent of clinical disease site and location of administered dose. While the influence of medium on dose calculation can be substantial for low energy sources or non-deeply seated implants, the influence…
Commissioning and quality assurance procedures for the HDR Valencia skin applicators
2016
The Valencia applicators (Nucletron, an Elekta company, Elekta AB, Stockholm, Sweden) are cup-shaped tungsten applicators with a flattening filter used to collimate the radiation produced by a high-dose-rate (HDR) 192 Ir source, and provide a homogeneous absorbed dose at a given depth. This beam quality provides a good option for the treatment of skin lesions at shallow depth (3-4 mm). The user must perform commissioning and periodic testing of these applicators to guarantee the proper and safe delivery of the intended absorbed dose, as recommended in the standards in radiation oncology. In this study, based on AAPM and GEC-ESTRO guidelines for brachytherapy units and our experience, a set …
On-Line Characterization of Gamma Radiation Effects on Single-Ended Raman Based Distributed Fiber Optic Sensor
2016
We report distributed temperature measurements based on Raman scattering performed during steady state $\gamma $ -ray irradiation at a dose rate of 1 kGy( ${\rm SiO}_{2}$ )/h and up to a total ionizing dose (TID) of $\sim 0.1\ \hbox{MGy}$ . We characterize on-line the evolution of the performances of a single-ended Raman distributed temperature sensor (RDTS) during the $\gamma $ -ray exposure of different classes of commercial multimode fibers (MMFs) acting as the sensing element. RDTS is influenced by the radiation-induced attenuation (RIA) phenomena leading to both large errors in the temperature measurements and a diminution of the useful sensing length. The amplitude of the radiation-in…
A study of Type B uncertainties associated with the photoelectric effect in low-energy Monte Carlo simulations
2021
The goal of this manuscript is to estimate Type B uncertainties in absorbed-dose calculations arising from the different implementations in current state-of-the-art Monte Carlo codes of low-energy photon cross-sections (<200 keV). Monte Carlo simulations are carried out using three codes widely used in the low-energy domain: PENELOPE-2018, EGSnrc, and MCNP. Mass energy-absorption coefficients for water, air, graphite, and their respective ratios; absorbed dose; and photon-fluence spectra are considered. Benchmark simulations using similar cross-sections have been performed. The differences observed between these quantities when different cross-sections are considered are taken to be a go…