Search results for "Absorption"
showing 10 items of 2701 documents
Many-body approach to low-energy pion-nucleus scattering
1993
Abstract We have extrapolated for low-energy pions ( T π = 0–50 MeV) the results for the pion-nucleus optical potential previously developed for pionic atoms. The evaluation is done using microscopic many-body techniques which allow us to separate the different contributions to the imaginary part of the potential and relate them to the different reaction channels: quasielastic and absorption. Elastic differential, reaction, absorption and quasielastic cross sections are evaluated for different nuclei and energies and contrasted with experiments. The agreement with data for the different channels, energies and nuclei is rather good with some isolated discrepancies.
Dependency of Energy-, Position- and Depth of Interaction Resolution on Scintillation Crystal Coating and Geometry
2008
Options for optimizing the energy and spatial resolution of gamma-ray imaging detectors based on thick, monolithic crystals shaped like flat-topped pyramids were studied. Monte Carlo simulations were made of the scintillation light transport for evaluating the effect of four parameters on the energy resolution, the spatial resolutions, and the depth of interaction (DOI) resolution of the gamma-ray imaging detector. These four parameters are: the reflectivity of the surface coating; the scatter mean free path; the absorption mean free path of the scintillation light; and the angle that defines the inclination of the sides of the pyramidal frustum. In real detectors, the values for the mean f…
Beta decay studies with total absorption spectroscopy and the Lucrecia spectrometer at ISOLDE
2017
26 pags., 21 figs., tab. -- Open Access funded by Creative Commons Atribution Licence 3.0
β-decay study of150Er,152Yb, and156Yb: Candidates for a monoenergetic neutrino beam facility
2011
The beta decays of ^{150}Er, ^{152}Yb, and ^{156}Yb nuclei are investigated using the total absorption spectroscopy technique. These nuclei can be considered possible candidates for forming the beam of a monoenergetic neutrino beam facility based on the electron capture (EC) decay of radioactive nuclei. Our measurements confirm that for the cases studied, the EC decay proceeds mainly to a single state in the daughter nucleus.
Radiation resistance and optical properties of lead fluoride Cherenkov crystals
1998
Abstract Optical properties of large size lead fluoride (PbF 2 ) crystals of three different manufacturers and their degradation caused by 60 Co γ-radiation have been investigated. Transmission losses have been systematically studied at absorbed energy doses between 0.1 and 7 kGy. Several radiation induced absorption bands have been observed. Optical bleaching with light of wavelengths ≳365 nm has been found very effective to restore the original characteristics even after repeated irradiations. This observation together with the high density and the ultraviolet extended transmission make PbF 2 an excellent choice for high rate and high resolution e.m. calorimetry.
Luminescent detectors of ionising radiation
2003
Abstract At present in slow neutron imaging an active layer of an imaging plate IP contains a mixture of storage phosphors, usually BaFBr:Eu 2+ used for imaging of X-rays, and a neutron converter material, usually Gd 2 O 3 , LiF. A novel Li-containing luminescent material perspective for a direct neutron conversion and storage is discussed. Irradiation of LiBaF 3 crystals results in generation of Frenkel defect pairs and creation of F-type centres responsible for three absorption bands in UV-and visible spectral region. Because photo-stimulation in each of these absorption bands leads to bleaching of induced absorption, the F-type colour centres are convenient for storage of radiation dose.…
Determination of helium number densities in high-frequency electrodeless plasma
2010
Abstract The number densities of He first excited states 2 3 S 1 , 2 1 S 0 , 2 3 P 0,1,2 , and 2 1 P 0 were measured by absorption and self-absorption methods. The emission lines in the range 290–730 nm were used to determine the number densities of He metastable and resonant states of inductively coupled high-frequency electrodeless lamps filled with helium at pressure 0.1 Torr. The obtained number densities of helium metastable levels 2 3 S 1 and 2 1 S 0 are 2×10 12 and 3×10 11 cm −3 , respectively. For the 2 3 P 0,1,2 and 2 1 P 0 levels the determined number densities are ten times smaller than that of the metastable levels. Values of number densities from measurements using both method…
Photonuclear reactions at intermediate energies
2008
Starting from basic couplings of the photons to mesons, nucleons and isobars a microscopic manybody theory is developped which allows one to evaluate different photonuclear reactions at intermediate energies. The theory is applied to obtain the total photonuclear cross section and the separation between γ absorption and (γ, π) reaction channels.
TAS measurements for reactor physics and nuclear structure
2011
In this contribution we will present recent total absorption measurements of the beta decay of neutron‐rich nuclei performed at the IGISOL facility of the Univ. of Jyvaskyla. In the measurements the JYFL Penning Trap was used as a high resolution isobaric separator. The total absorption technique will be described and the impact of recent results in the fields of reactor physics (decay heat calculations) and nuclear structure will be discussed.
Physics at MAMI
2008
The Mainz Microtron MAMI has delivered a high quality electron beam with maximum energy of 880MeV for many years. Recently the MAMI C stage with its maximum energy of 1.5GeV was put into operation successfully and is delivering beam routinely now. The A1 collaboration is doing electron scattering experiments with a “Three Spectrometer Setup”. A first experiment using the MAMI C beam to measure the “Recoil polarisation and beam-recoil double polarisation of eta electroproduction on the proton in the region of the S11(1535) resonance” has been finished. A new, very compact magnetic spectrometer (KaoS) suitable especially for the detection of kaons is being installed now. The A2 collaboration …