Search results for "Absorption"
showing 10 items of 2701 documents
Indirect Determination of Cyanide by Atomic Absorption Spectrometry
1995
Abstract Two methods for determination of cyanide by atomic absorption spectrometry (AAS) are developed. Both methods are based on the formation of an ion association compound between a metal complex, (Ag(CN)2 − or Cu(CN)3 2-), and a quaternary ammonium ion (benzyldimethylhexadecylammonium ion). The ion association compound is extracted into isomethylbutylketone (IBMK) and the metal is determined by AAS directly in extract. The method based on the formation of silver cyanide complex provides a reproducibility of 2.5%, a recovery of 99% and a detection limit of 1.7 μg/L while the method based on the formation of copper complex gives a reproducibility of 6%, a recovery of 93% and a detection …
Some observations on the sensitivity of flow-injection techniques for atomic absorption spectrophotometry
1989
Abstract Different strategies for coupling flow-injection manifolds to atomic absorption spectrometers in order to obtain better sensitivity are compared. Using a T-connector interface, different carriers and flow compensation solvents have been assayed in an attempt to improve the sensitivity of flow-injection analysis. Manganese and copper determinations in sewage sludge have been used as a test system and the analytical parameters of both batch and flow-injection methods are compared.
Vapor-phase introduction of alkyltin compounds in atomic absorption spectrophotometry
1990
Abstract Different systems for the introduction of alkyltin compounds in atomic absorption spectrophotometry using the vapor-phase introduction approach have been compared. Samples and standards were introduced in both quartz cell and flame atomizer using a vertical and a horizontal reactor. The better sensitivity was obtained with the quartz cell and the horizontal reactor.
Resolution of overlapped non-absorbing and absorbing solutes using either an absorption null-balance detection window or multivariate deconvolution a…
2004
Abstract Non-absorbing alkyl ether sulfates (AES) can be separated using anthraquinone-2-carboxylic acid (AQCA) as a probe; however, absorbing alkyl benzene sulfonates (ABS), if present, interfere indirect detection of most AES oligomers. Overcoming of this interference, as well as the simultaneous characterisation and evaluation of AES, fatty acids and ABS, was accomplished by using a diode-array detector and the procedures here discussed. First, it was shown that ABS can be made undetectable by using a 9 nm wide and 227 nm centred charge-absorptivity null-balance detection window (NBDW), where its contribution to the absorbance cancels the dilution effects that its presence induces on the…
Methylmercury and inorganic mercury determination in fish by cold vapour generation atomic absorption spectrometry
2000
Abstract Given that organic mercury is more dangerous than the inorganic form and that it is converted into methylmercury by biological methylation, we have studied and optimized a simple method for measuring both organic and inorganic mercury contents in fish, using a spectroscopic vapour generation technique, with a sequential reduction of the digested sample with stannous chloride and sodium tetrahydroborate. Prior to applying the method the sample was subjected to alkaline wet digestion. Due to the matrix interferences calibration curves with matrix addition were needed for mercury determinations. The analytical parameters of the method were: linearity from 10 to 200 ng of Hg in the red…
Arsenic content of Spanish cows' milk determined by dry ashing hydride generation atomic absorption spectrometry.
1994
SummaryThe arsenic content of cows' milk consumed in Spain was determined. A procedure using dry ashing hydride generation atomic absorption spectrometry was developed for the purpose. Experimental conditions for the destruction of organic matter were established and an interference study was carried out. The method developed has a detection limit of 0·1 ng/g, a relative SD of 5%, and a recovery (mean ± CSI) of 100 ± 4%. The accuracy of the method was checked by analysis of a certified sample of IAEA milk powder (mean ± CSI: certified, 4·85 ± 0·32 ng/g; found, 5·04 ± 0·81 ng/g). The proposed procedure was used to analyse cows' milk samples. The extremely low arsenic levels found do not pres…
Active alkaline traps to determine acidic-gas ratios in volcanic plumes: Sampling techniques and analytical methods
2014
In situ measurements have been the basis for monitoring volcanic gas emissions for many years and—being complemented by remote sensing techniques—still play an important role to date. Con- cerning in situ techniques for sampling a dilute plume, an increase in accuracy and a reduction of detection limits are still necessary for most gases (e.g., CO2, SO2, HCl, HF, HBr, HI). In this work, the Raschig-Tube tech- nique (RT) is modified and utilized for application on volcanic plumes. The theoretical and experimental absorption properties of the RT and the Drechsel bottle (DB) setups are characterized and both are applied simultaneously to the well-established Filter packs technique (FP) in the …
On-line bi-directional electrostacking for As speciation/preconcentration using electrothermal atomic absorption spectrometry.
2006
A method using bi-directional electrostacking (BDES) in a flow system is presented for As preconcentration and speciation analysis. Some parameters such as electrostacking time and applied voltage, support buffers and their concentrations were investigated. Boric acid plus sodium hydroxide at 0.1mol/l concentration was selected as support buffer to improve the pre-concentration factor (PF) for As(V). An analytical range from 2.0 to 50.0mugl(-1), and 0.35mugl(-1) as limit of detection, when applied 750V for 20min, were achieved. Under these conditions, a pre-concentration factor of 4.8 was obtained. The proposed method was applied to determine As(V) in mineral water and natural water samples…
Enhanced nanoscopy of individual CsPbBr3 perovskite nanocrystals using dielectric sub-micrometric antennas
2020
We demonstrate an efficient, simple, and low-cost approach for enhanced nanoscopy in individual green emitting perovskite (CsPbBr3) nanocrystals via TiO2 dielectric nanoantenna. The observed three- to five-fold emission enhancement is attributed to near-field effects and emission steering promoted by the coupling between the perovskite nanocrystals and the dielectric sub-micrometric antennas. The dark-field scattering configuration is then exploited for surface-enhanced absorption measurements, showing a large increase in detection sensitivity, leading to the detection of individual nanocrystals. Due to the broadband spectral response of the Mie sub-micrometric antennas, the method can be e…
Congenital secretory diarrhoea caused by activating germline mutations in GUCY2C
2016
Objective Congenital sodium diarrhoea (CSD) refers to a form of secretory diarrhoea with intrauterine onset and high faecal losses of sodium without congenital malformations. The molecular basis for CSD remains unknown. We clinically characterised a cohort of infants with CSD and set out to identify disease-causing mutations by genome-wide genetic testing. Design We performed whole-exome sequencing and chromosomal microarray analyses in 4 unrelated patients, followed by confirmatory Sanger sequencing of the likely disease-causing mutations in patients and in their family members, followed by functional studies. Results We identified novel de novo missense mutations in GUCY2C, the gene encod…