Is clinical experience important for obtaining the primary stability of dental implants with aggressive threads? An ex vivo study
2018
GECKILI, ONUR/0000-0002-7852-3915; dayan, suleyman cagatay/0000-0003-3081-9618; Bilhan, Hakan/0000-0003-1787-3003 WOS:000460131200015 PubMed ID: 30818319 Background: The aim of this study was to investigate the clinicians' experience on maintaining the primary stability of implants with aggressive threads belonging to a novel dental implant system. Material and Methods: Three hundred implants with aggressive threads were inserted in fresh bovine ribs mimicking Type IV bone by five clinicians which were classified according to their previous experience of total number of implant insertion. An independent examiner measured the primary stability of all implants after insertion by using resonan…
Is the re-use of sterilized implant abutments safe enough? (Implant abutment safety)
2019
Background: The reuse of implant healing abutments is common in dental practice. Effective elimination of bacteria and viruses is accomplished by conventional sterilization. The aim of this work was to explore the eventual survival of microorganisms on sterilized healing abutments and to rule out the presence of transmissible organic material after standard procedures. Material and Methods: A total of 55 healing abutments previously used in patients will be washed and sterilized in a steam autoclave at 121oC for 15 min. Each healing abutment will be cultured in Brain Heart Infusion broth (BHI) under strict aseptic conditions. Besides, two control groups will be included: one of 3 unused hea…
Definitive Abutments Placed at Implant Insertion and Never Removed: Is It an Effective Approach? A Systematic Review and Meta-Analysis of Randomized …
2017
Purpose To assess whether repeated abutment disconnections and reconnections have any impact on peri-implant bone resorption and soft tissue healing. Materials and Methods Electronic and manual searches were conducted for English-language articles published up to March 2017 that identified a relation between repeated disconnections of implant abutments (PA group) and prosthetic or implant failures, complications, marginal bone loss (MBL), soft tissue healing, and esthetic evaluation (pink esthetic score [PES]) after at least 1 year of function compared with implants receiving a final abutment at the time of implant placement (DA group). Results Fourteen articles (535 patients with 994 impla…
Microbial Leakage at the Implant-Abutment Connection Due to Implant Insertion Maneuvers: Cross-Sectional Study 5 Years Postloading in Healthy Patient…
2015
The aim of this study was to test if stress on the prosthetic connection during insertion maneuvers can induce micro-warping at the implant connection. From September 2011 to July 2013, patients with implants loaded for at least 5 years that were placed with 2 different insertion implant mounters—MP (conventional) and ME (mountless)—were selected from all of those who had received dental implant therapy in the past and were attending routine check-up or spontaneous visits during the study period. Samples were obtained from inside the connection and the abutment surface using absorbent sterile paper tips. Quantitative real-time polymerase chain reaction was performed for total bacterial coun…
Modelling the Electromechanical Impedance Method for the Prediction of the Biomechanical Behavior of Dental Implant Stability
2015
Abstract We propose the electromechanical impedance (EMI) technique to assess the stability of dental implants. The technique consists of bonding a piezoelectric transducer to the element to be monitored. Conventionally, electromechanical admittance is used to diagnose structural damage. In this study, we created a 3D finite element model to mimic a transducer bonded to the abutment of a dental implant placed in a host bone site. We simulated the healing after surgery by changing the Young's modulus of the bone-implant interface. The results show that as the Young's modulus of the interface increases, the electromechanical characteristic of the transducer changes.