Search results for "Accelerator"
showing 10 items of 1507 documents
On-line yields obtained with the ISOLDE RILIS
2003
The ISOLDE resonance ionization laser ion source (RILIS) allows to ionize efficiently and selectively many metallic elements. In recent yield surveys and on-line experiments with the ISOLDE RILIS we observed 23–34 Mg, 26–34 Al, 98–132 Cd, 149 Tb, 155–177 Yb, 179–200 Tl, 183–215 Pb and 188–218 Bi. The obtained yields are presented together with measured release parameters which allow to extrapolate the release efficiency towards more exotic (short-lived) nuclides of the same elements. 2002 Elsevier Science B.V. All rights reserved.
Optical spectroscopy using mass-separated beams: Nuclear properties of unstable indium and tin isotopes
1987
Abstract Collinear fast-beam laser-spectroscopy has been used to measure the hyperfine structure and isotope shift of several indium and tin isotopes. The related experimental techniques are described, including the preparation of mass-separated beams of neutron-deficient indium and tin isotopes at the GSI on-line mass separator following fusion-evaporation reactions. The deviation of the observed dependence of the charge radii upon the neutron number from the expected behaviour is briefly discussed.
The REX-ISOLDE project
1998
Abstract REX-ISOLDE [1] is an experiment at ISOLDE/CERN with a twofold aim: (i) to demonstrate a novel efficient scheme for the acceleration of radioactive ions from the online mass separator ISOLDE to energies around the Coulomb barrier. (ii) to perform first nuclear physics experiments by studying the structure of the neutron-rich (N = 20, N = 28) nuclei by Coulomb excitation and neutron transfer reactions. An overview on the different components of the radioactive beam accelerator is given with special emphasis on the separation possibilities and ion number capabilities of the system.
Cooling and bunching of ion beams for collinear laser spectroscopy
2003
A greatly increased sensitivity in collinear laser spectroscopy experiments has been achieved by the application of new on-line ion cooling and bunching techniques. Cooling of a low-energy ion beam to low emittance and low velocity spread is shown to increase the peak efficiency while bunching the beam results in highly efficient background suppression.
Ultrafast Dynamics of Magnetic Domain Structures Probed by Coherent Free-Electron Laser Light
2013
Synchrotron radiation news 26(6), 27 - 32 (2013). doi:10.1080/08940886.2013.850384
Untersuchung der Feldelektronenemission und ihrer Temperaturabh�ngigkeit bei Stromst�rken zwischen 10?14 und 10?19 A
1964
The field emission of a tungsten point cathode at very low emission currents was investigated by means of a secondary emission multiplier. The validity of the Fowler-Nordheim equation was experimentally confirmed within the range from 10−8 to 10−19 A. The dependence of the total emission current on temperature and electrical field strength was measured in the transition region between thermionic and field emission. A comparison is drawn with the theory ofMurphy andGood.
Effect of double frequency heating on the lead afterglow beam currents of an electron cyclotron resonance ion source
2017
International audience; The effect of double frequency heating on the performance of the CERN GTS-LHC 14.5 GHz ElectronCyclotron Resonance (ECR) ion source in afterglow mode is reported. The source of the secondary microwave frequency was operated both in pulsed and continuous wave (CW) modes within the range of 12–18 GHz. The results demonstrate that the addition of the secondary frequency can significantly impact the extracted beam currents and the temporal stability of the beam during the afterglow discharge. For example, up to a factor of 2.6 increase was achieved for 208Pb35+ and a factor of 3.1 for 208Pb37+ compared to single frequency afterglow currents. It is shown that these effect…
Atom beam emersion from hot cavity laser ion sources
2020
Abstract Ion sources exploiting laser resonance ionization offer efficient and element-selective radioactive ion beam production at the leading isotope separation on-line facilities worldwide. Most commonly, laser resonance ionization takes place inside a resistively heated atomizer tube directly coupled to the production target, where the element of interest is evaporated and provided as atomic vapor. While naturally the majority of atoms is ionized inside this hot cavity, a fraction of the neutrals effuses towards the high voltage beam extraction system of the subsequent mass separator. We report on several systematic investigations on this phenomenon regarding its significance and implic…
Development of economic MeV-ion microbeam technology at Chiang Mai University
2017
Abstract Developing high technologies but in economic manners is necessary and also feasible for developing countries. At Chiang Mai University, Thailand, we have developed MeV-ion microbeam technology based on a 1.7-MV Tandetron tandem accelerator with our limited resources in a cost-effective manner. Instead of using expensive and technically complex electrostatic or magnetic quadrupole focusing lens systems, we have developed cheap MeV-ion microbeams using programmed L-shaped blade aperture and capillary techniques for MeV ion beam lithography or writing and mapping. The programmed L-shaped blade micro-aperture system consists of a pair of L-shaped movable aperture pieces which are contr…
Enhancing the extraction of laser-ionized beams from an arc discharge ion source volume
2018
© 2018 The Author(s) The Versatile Arc Discharge and Laser Ion Source (VADLIS) is a recently established ion source for the CERN-ISOLDE radioactive ion beam facility. It offers either electron-impact ionization (VADIS-mode) or resonance laser ionization (RILIS-mode). The choice of operating mode depends on the element of interest or the required beam purity. Particle-in-cell simulations using the VSim software show that the ion extraction efficiency of the VADLIS in RILIS-mode can be improved if it is equipped with an insulated extractor plate, to which an optimal voltage can be applied. This enables optimization of the RILIS-mode ion extraction independently of the electron density. Experi…