Search results for "Accelerator"
showing 10 items of 1507 documents
Study of energy response and resolution of the ATLAS barrel calorimeter to hadrons of energies from 20 to 350 GeV
2010
A fully instrumented slice of the ATLAS detector was exposed to test beams from the SPS (Super Proton Synchrotron) at CERN in 2004. In this paper, the results of the measurements of the response of the barrel calorimeter to hadrons with energies in the range 20 to 350 GeV and beam impact points and angles corresponding to pseudorapidity values in the range 0.2-0.65 are reported. The results are compared to the predictions of a simulation program using the Geant 4 toolkit.
Search for Higgs boson production in trilepton and like-charge electron-muon final states with the D0 detector
2013
We present a search for Higgs bosons in multilepton final states in pp-bar collisions at sqrt(s)=1.96 TeV recorded with the D0 detector at the Fermilab Tevatron Collider, using the full Run II data set with integrated luminosities of up to 9.7 fb-1. The multilepton states considered are two electron plus muon, electron with two muons, muon with two hadronic tau leptons, and like-charge electron-muon pairs. These channels directly probe the HVV (V=W,Z) coupling of the Higgs boson in production and decay. The muon with two hadronic tau lepton channel is also sensitive to H to tau lepton pair decays. Upper limits at the 95% C.L on the rate of standard model Higgs boson production are derived i…
Particle Production in the Color Class Condensate: from electron-proton DIS to proton-nucleus collisions
2013
We study single inclusive hadron production in proton-proton and proton-nucleus collisions in the CGC framework. The parameters in the calculation are obtained by fitting electron-proton deep inelastic scattering data. The obtained dipole-proton amplitude is generalized to dipole-nucleus scattering without any additional nuclear parameters other than the Woods-Saxon distribution. We show that it is possible to use an initial condition without an anomalous dimension and still obtain a good description of the HERA inclusive cross section and LHC single particle production measurements. We argue that one must consistently use the proton transverse area as measured by a high virtuality probe in…
Measurement of the $W$ boson mass with the D0 detector
2012
We give a detailed description of the measurement of the $W$ boson mass, $M_W$, performed on an integrated luminosity of 4.3 fb$^{-1}$, which is based on similar techniques as used for our previous measurement done on an independent data set of 1 fb$^{-1}$ of data. The data were collected using the D0 detector at the Fermilab Tevatron Collider. This data set yields $1.68\times 10^6$ $W\rightarrow e\nu$ candidate events. We measure the mass using the transverse mass, electron transverse momentum, and missing transverse energy distributions. The $M_W$ measurements using the transverse mass and the electron transverse momentum distributions are the most precise of these three and are combined …
The beam and detector for the NA48 neutral kaon CP violation experiment at CERN
2007
The beam and detector, used for the NA48 experiment, devoted to the measurement of Re (ε{lunate}′ / ε{lunate}), and for the NA48/1 experiment on rare KS and neutral hyperon decays, are described. © 2007 Elsevier B.V. All rights reserved.
Search for lepton flavor violating decays τ±→l± ω
2008
A search for lepton flavor violating decays of a {tau} to a lighter-mass charged lepton and an {omega} vector meson is performed using 384.1 fb{sup -1} of e{sup +}e{sup -} annihilation data collected with the BABAR detector at the Stanford Linear Accelerator Center PEP-II storage ring. No signal is found, and the upper limits on the branching ratios are determined to be {beta}({tau}{sup {+-}} {yields} e{sup {+-}}{omega}) < 1.1 x 10{sup -7} and {beta}({tau}{sup {+-}} {yields} {mu}{sup {+-}}{omega}) < 1.0 x 10{sup -7} at 90% confidence level.
A collision timing monitor for SuperKEKB
2017
Abstract The analysis of beamstrahlung radiation, emitted from a beam of charged particles due to the electromagnetic interaction with a second beam of charged particles, provides a diagnostic tool that can be used to monitor beam–beam collisions in a e + e − storage ring. In this paper we show that the beamstrahlung time profile is related to the timing of the collisions and the length of the beams, and how its measurement can be used to monitor and optimize collisions at the interaction point of the SuperKEKB collider. The method has a unique passive monitor capability, since it allows to monitor the timing of the collision without disturbing (scanning) the beam–beam timing, which needs t…
Electron and Photon Identification in the D0 Experiment
2013
The electron and photon reconstruction and identification algorithms used by the D0 Collaboration at the Fermilab Tevatron collider are described. The determination of the electron energy scale and resolution is presented. Studies of the performance of the electron and photon reconstruction and identification are summarized.
Performance and characterization of the FinEstBeAMS beamline at the MAX IV Laboratory
2021
European Regional Development Fund (grant No. TK-141 HiTechDevices 2014-2020.4.01.15-0011 to University of Tartu; grant No. MAX-TEENUS 2014-2020.4.01.20-0278 to University of Tartu; grant No. Eesti Kiirekanal SLOFY11156T/1 to University of Tartu); Estonian Research Council (grant No. PRG-629 to University of Tartu); Jane & Aatos Erkko Foundation (grant No. SOFUS); Business Finland (grant No. 1464/31/2019); Academy of Finland (grant No. 319042; grant No. 326461; grant No. 326406; grant No. 320165); University of Oulu; University of Turku; Tampere University; University of Tartu.
A short-orbit spectrometer for low-energy pion detection in electroproduction experiments at MAMI
2017
A new Short-Orbit Spectrometer (SOS) has been constructed and installed within the experimental facility of the A1 collaboration at Mainz Microtron (MAMI), with the goal to detect low-energy pions. It is equipped with a Browne-Buechner magnet and a detector system consisting of two helium-ethane based drift chambers and a scintillator telescope made of five layers. The detector system allows detection of pions in the momentum range of 50 - 147 MeV/c, which corresponds to 8.7 - 63 MeV kinetic energy. The spectrometer can be placed at a distance range of 54 - 66 cm from the target center. Two collimators are available for the measurements, one having 1.8 msr aperture and the other having 7 ms…