Search results for "Accuracy"
showing 10 items of 277 documents
The exact finite‐difference scheme for vector boundary‐value problems with piece‐wise constant coefficients
1998
We will consider the exact finite‐difference scheme for solving the system of differential equations of second order with piece‐wise constant coefficients. It is well‐known, that the presence of large parameters at first order derivatives or small parameters at second order derivatives in the system of hydrodynamics and magnetohydrodynamics (MHD) equations (large Reynolds, Hartmann and others numbers) causes additional difficulties for the applications of general classical numerical methods. Thus, important to work out special methods of solution, the so‐called uniform converging computational methods. This gives a basis for the development of special monotone finite vector‐difference schem…
Accuracy and Safety of Ultrasound-Guided Core Needle Biopsy of Soft Tissue Tumors in an Outpatient Setting: A Sarcoma Center Analysis of 392 Consecut…
2021
Simple Summary In patients with unclear soft tissue lesions, treatment planning largely depends on histology. Core needle biopsy is the diagnostic standard in these cases. The aim of this retrospective study was to investigate accuracy and safety of ultrasound guided core needle biopsy at a tertiary referral center. We show that ultrasound guided biopsy was feasible as a one stop shop procedure in an outpatient setting in 87.6% of the cases. The rate of conclusive biopsies was 88.5%. After surgical resection, the dignity, tumor type and histopathological grading of the biopsy matched one of the resection specimens in 97.2%, 92.7% and 92.5% of the cases, respectively. Major complications occ…
Diagnóstico etilógico de la disfunción ventricular izquierda con tomografia computerizada: comparación con coronariografía y cardiorresonancia
2012
[EN] Introduction and objectives To evaluate the capability of multidetector computed tomography to diagnose the coronary etiology of left ventricular dysfunction compared with using invasive coronary angiography and magnetic resonance. Methods Forty consecutive patients with left ventricular dysfunction of uncertain etiology underwent invasive coronary angiography and contrast magnetic resonance. All patients were evaluated with multidetector computed tomography including coronary calcium presence and score, noninvasive coronary angiography, and myocardial tissue assessment. Results The sensitivity and specificity of the presence of coronary calcium to identify left ventricular dysfunction…
Improving diagnostic accuracy of MDCT coronary angiography in patients with mild heart rhythm irregularities using ECG editing
2006
OBJECTIVE. The objective of our study was to compare diagnostic accuracy of MDCT coronary angiography in a population of patients with mild heart rhythm irregularities before and after editing the ECG. SUBJECTS AND METHODS. Thirty-eight patients who underwent MDCT coronary angiography and conventional coronary angiography were enrolled in the study. The inclusion criterion was the presence of mild heart rhythm irregularities (i.e., premature beats; atrial fibrillation; mistriggering; or low heart rate, defined as 40 beats per minute or less) during the scan. All patients underwent MDCT with the following parameters: 16 detectors; collimation, 0.75 mm; gantry rotation time, 375 msec; 120 kV;…
INFLUENCE OF INTRA-CORONARY ENHANCEMENT ON DIAGNOSTIC ACCURACY WITH 64-SLICE CT CORONARY ANGIOGRAPHY
2008
We assessed the effect of intra-coronary attenuation on diagnostic accuracy using 64-slice computed tomography coronary angiography (CT-CA). We enrolled 170 patients with suspected coronary artery disease who underwent conventional coronary angiography (CA) and 64-slice CT-CA (100 ml of Iomeprol 400 mg I/ml at 4 ml/s). The study population was divided into two groups (85 patients each based on median attenuation of 326 HU) based on mean arterial attenuation; group 1 with low attenuation and group 2 with high attenuation. Diagnostic accuracy for the detection of significant coronary artery stenosis was determined for both groups using CA as reference standard. Overall, 163 significant stenos…
Diagnostic accuracy of adding copeptin to cardiac troponin for non-ST-elevation myocardial infarction: A systematic review and meta-analysis.
2018
Introduction This study aimed to determine the diagnostic accuracy of adding copeptin to cardiac troponin (cTn) on admission to the emergency department (ED) for non-ST elevation myocardial infarction (NSTEMI) compared to cTn alone. Materials and methods A literature search of MEDLINE, EMBASE, and the Cochrane Library was performed (search date: April 13, 2018). Primary studies were included if they accurately reported on patients with symptoms suggestive of acute myocardial infarction and measured both cTn alone and cTn with copeptin upon admission to the ED. The patients with evidence of ST elevation myocardial infarction were excluded. To assess the risk of bias for the included studies,…
New optical paper sensor for in situ measurement of hydrogen sulphide in waters and atmospheres
2016
A novel and low-cost colorimetric sensor for the determination of hydrogen sulphide in environmental samples has been developed. This sensor is based on the immobilization of the reagent N,N-Dimethyl-p-phenylenediamine and FeCl3 in paper support, in which the H2S is adsorbed in order to give rise to the formation of methylene blue as reaction product. The sensor has been applied to determine H2S in water and air samples. Two different sampling systems for H2S caption from the air have been assayed: active and passive sampling. The analytical properties of the different systems have been obtained and compared. The analytical signals, corresponding to the methylene blue, have been obtained me…
A new flow cell design for chemiluminiscence analysis.
2001
The present study proposes a new flow cell called a bundle cell for chemiluminescence analysis. The results obtained were compared with those achieved by manual and automated batch procedures and flow manifolds with different cells: an common quartz flow cell, a helix cell and the most used spiral cell. Figures of merit such as limit of detection, sensitivity, accuracy and precision for the Cr(III) determination were established with light emission produced by catalysed Cr(III) luminol oxidation by hydrogen peroxide in a basic aqueous solution. An improvement in sensitivity about 50% as compared with the spiral cell and even larger with respect to the other flow cells tested was observed. T…
Addition of thiourea and hydrochloric acid: Accurate nanogram level analysis of mercury in humic-rich natural waters by inductively coupled plasma ma…
2020
Abstract An analytical method was developed for the direct determination of total mercury in natural waters at low ng L−1 level by inductively coupled plasma mass spectrometry (ICP-MS). The presented method overcomes previously observed problems relating to poor spike recoveries by adding 0.12% thiourea in addition to 3% HCl to all samples and standards. The sample preparation is fast and easy to perform by the developed method since it requires only the addition of HCl and thiourea to the water samples. A very low instrument detection limit (0.4 ng L−1) was obtained without time-consuming preconcentration procedures. The accuracy and precision of the developed method were found excellent b…
Copper, iron and zinc determinations in human milk using FAAS with microwave digestion
2000
Abstract A method for determining copper, iron and zinc in human milk was optimized and validated. It includes microwave mineralization of the sample and measuring the elements by flame atomic absorption spectroscopy (FAAS). Only 2 ml of milk is needed, and the method is free of matrix interferences. The values obtained for the detection limits (0.07; 0.07; 0.11 μg/ml milk, for copper, iron and zinc) precision of the method, intra-assay (2.9; 5.2; 6.1%RSD for copper, iron and zinc) and accuracy, evaluated using recovery assays (98.8; 100.4; 95.9% for copper, iron and zinc) show that the method is useful for the purpose mentioned. Moreover, the method is rapid and simple, and the determinati…