Predicting risk and outcomes for frail older adults: a protocol for an umbrella review of available frailty screening tools

2015

REVIEW QUESTION / OBJECTIVE  The aim of this systematic review is to comprehensively search the available literature and to summarize the best available evidence from systematic reviews in relation to published screening tools to identify pre-frailty and frailty in older adults, that is: (i) to determine their psychometric proprieties; (ii) to assess their capacity to detect pre-frail and frail conditions against established methods; and (iii) to evaluate their predictive ability. More specifically, the review will focus on the following questions: - What is the reliability and validity of existing screening tools that assess pre-frailty/frailty in older patients? - How sensitive and specif…

RiskResearch designGerontologyreliability and validitymedicine.medical_specialtyPsychometricsPsychometricsInstitutionalisationFrail ElderlyfrailtymedicineHumansMass ScreeningGeriatric AssessmentGeneral NursingMass screeningAgedAged 80 and overGeriatricsbusiness.industryscreeningpredictive abilityReproducibility of ResultsCognitionGeneral MedicineMental healthfrail elderlydiagnostic test accuracyReview Literature as TopicSystematic reviewpre-frailtyResearch Designbusiness
researchProduct

Comparative in vitro study of the accuracy of impression techniques for dental implants: Direct technique with an elastomeric impression material ver…

2019

Background The aim of this study was to compare a conventional technique (elastomeric impression material - EIM) and a digital technique (scanner digital model – SDM) on a six-analog master model (MM) to determine which was the most exact. Material and Methods Twenty impressions were taken of a master model (EIM) and twenty scanned impressions (SDM) (True Definition). A coordinate measuring machine (CMM) was used to measure the distances between adjacent analogues (1-2, 2-3, 3-4, 4-5, 5-6), intermittently positioned analogues (1-4, 3-6) and the most distal (1-6). Reference values were established from the master model, which were compared with the two impression techniques. The significance…

ScannerDental Impression TechniqueIn Vitro TechniquesCoordinate-measuring machine03 medical and health sciences0302 clinical medicineIn vitro study030212 general & internal medicineGeneral DentistryMathematicsConventional techniqueDental ImplantsIntraoral scannerResearchDental Impression Materials030206 dentistryDirect Technique:CIENCIAS MÉDICAS [UNESCO]Models DentalImpressionOtorhinolaryngologyElastomersDimensional Measurement AccuracyReference valuesUNESCO::CIENCIAS MÉDICASComputer-Aided DesignSurgeryOral SurgeryBiomedical engineeringMedicina oral, patologia oral y cirugia bucal
researchProduct

The use of vineyard spectral signatures to identify table grape cultivars

2021

Vineyards have characteristic responses to sunlight. The reflectance values at the different wavelengths are typical of vegetation and define its spectral signature. The aim of this work was to determine the spectral signatures of table grape vineyards located in the production area of Robinvale (Victoria, Australia) in order to identify cultivars in the vineyard. Spectral signatures were detected from images in eight bands from the Worldview 3 platform. Spectral signatures for a representative number of plots were extracted using satellite reflectance images for each cultivar. Spectral signatures were also collected in the field, from the same cultivars, with a FieldSpec® HandHeld 2 portab…

Settore AGR/03 - Arboricoltura Generale E Coltivazioni ArboreeHorticultureClassification accuracy Satellite imagery Spectral characteristics SpectroradiometerSpectral signatureTable grapeEnvironmental scienceCultivarHorticultureVineyardActa Horticulturae
researchProduct

Off-line scan path planning for robotic NDT

2018

This work presents computer-aided scan path generation for robotic non-destructive testing of complex shaped test-pieces. Off-line programmed scan path was used to robotically inspect an aluminium fixed leading edge skin panel of an aircraft wing by means of swept frequency eddy currents method. Eddy currents probe was deployed by means of a six-axis robotic arm KUKA KR5 arc. Reverse engineering of the test-piece was carried out to reconstruct CAD model of its surface. Positioning accuracy of the performed continuous scan was measured with a laser tracker in accordance with ISO 9283:1998 and is reported in the paper. The positional uncertainty of the NDT scan calculated as the standard devi…

Settore ING-IND/14 - Progettazione Meccanica E Costruzione Di MacchineEddy current NDTTKRoboticsReverse engineeringQCOff-line path planningPath accuracy
researchProduct

Some Numerical Remarks on a Meshless Approximation Method

2016

In this paper we consider sources of enhancement for the Smoothed Particle Hydrodynamics method in approximating a function and its derivatives. It is well known that the standard formulation is usually poor when scattered data distribution is considered or when the approximation near the boundary occurs. In this paper studies on the accuracy are provided and assessed with gridded and scattered data distribution in the problem domain. The improvements of the method are addressed and supporting numerical experiments are included.

Settore ING-IND/26 - Teoria Dello Sviluppo Dei Processi ChimiciDistribution (number theory)accuracyBoundary (topology)010103 numerical & computational mathematicsFunction (mathematics)01 natural sciences010101 applied mathematicsSmoothed-particle hydrodynamicsSettore MAT/08 - Analisi NumericaSettore ING-IND/31 - ElettrotecnicaProblem domainkernel functionApplied mathematicsmeshless methoderror norm0101 mathematicsAlgorithmMathematics
researchProduct

Computer assisted diagnosis (CAD) in mammography. Comparison of diagnostic accuracy of a new algorithm (Cyclopus(R), Medicad) with two commercial sys…

2008

The study compares the diagnostic accuracy (correct identification of cancer) of a new computer-assisted diagnosis (CAD) system (Cyclopus) with two other commercial systems (R2 and CADx). Cyclopus was tested on a set of 120 mammograms on which the two compared commercial systems had been previously tested. The set consisted of mammograms reported as negative, preceding 31 interval cancers reviewed as screening error or minimal sign, and of 89 verified negative controls randomly selected from the same screening database. Cyclopus sensitivity was 74.1% (R2=54.8%; CADx=41.9%) and was higher for interval cancers reviewed as screening error (90.9%; R2=54.5%; CADx=81.8%) compared with those revie…

Settore ING-INF/05 - Sistemi Di Elaborazione Delle Informazionimedicine.medical_specialtymedicine.diagnostic_testbusiness.industryBreast carcinomaSettore FIS/01 - Fisica SperimentaleCADDiagnostic accuracyBreast NeoplasmsGeneral MedicineSensitivity and SpecificitySettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Predictive Value of TestsmedicineComputer-assisted diagnosiMammographyHumansRadiology Nuclear Medicine and imagingMedical physicsFemaleRadiologyDiagnosis Computer-AssistedbusinessAlgorithmsMammography
researchProduct

Some numerical modelings beyond the mesh

2015

In recent years meshless methods have gained much attention in several application areas of science. These methods benefit of savings due to the elimination of meshing process and are suite to handle changes in the geometry of the domain of interest. Further advantages come from the ease of implementation, which makes computer codes very flexible. We present some numerical experiences lying in the meshless framework dealing with domain and boundary-type methods.

Settore MAT/08 - Analisi NumericaMFSnumerical accuracySPH
researchProduct

An Instrument-Assisted coracoid pain test: an exploratory diagnostic accuracy study

2022

The coracoid pain test (CPT) could contribute to the diagnosis of frozen shoulder (FS) with palpation. However, due to assessor performance these values might be unreliable. Therefore, the aim was to explore the diagnostic accuracy of an instrument-assisted CPT and two alternative approaches (pain severity and side comparison) for assistance in the diagnosis of FS. Patients with FS and healthy age-matched controls were recruited. All participants underwent the instrument-assisted CPT on both shoulders with a pressure algometer. Sensitivity, specificity, and likelihood ratios were determined for the three approaches. In total, 35 patients with FS and 35 healthy participants were included. Th…

ShoulderFisioteràpiaFerides i lesions TractamentHealth Toxicology and MutagenesisPublic Health Environmental and Occupational HealthPainSensitivity and Specificityfrozen shoulder; diagnostic test accuracy; coracoid pain test; diagnostic testsExtremitatsChemistryCross-Sectional StudiesDiagnòsticBursitisHumansHuman medicineBiology
researchProduct

Rapid parameter determination of discrete damped sinusoidal oscillations

2020

We present different computational approaches for the rapid extraction of the signal parameters of discretely sampled damped sinusoidal signals. We compare time- and frequency-domain-based computational approaches in terms of their accuracy and precision and computational time required in estimating the frequencies of such signals, and observe a general trade-off between precision and speed. Our motivation is precise and rapid analysis of damped sinusoidal signals as these become relevant in view of the recent experimental developments in cavity-enhanced polarimetry and ellipsometry, where the relevant time scales and frequencies are typically within the ∼1 − 10 µs and ∼1 − 100 MHz ranges, …

Signal Processing (eess.SP)Accuracy and precisionPhysics - Instrumentation and DetectorsAcousticsPolarimetryFOS: Physical sciences02 engineering and technologyApplied Physics (physics.app-ph)01 natural sciencesSignal010309 opticssymbols.namesakeOptics0103 physical sciencesFOS: Electrical engineering electronic engineering information engineeringElectrical Engineering and Systems Science - Signal ProcessingPhysicsbusiness.industrySpectral densityInstrumentation and Detectors (physics.ins-det)Physics - Applied Physics021001 nanoscience & nanotechnologyAtomic and Molecular Physics and OpticsMicrosecondFourier transformsymbols0210 nano-technologybusinessMatrix methodOptics (physics.optics)Physics - Optics
researchProduct

Rapid parameter estimation of discrete decaying signals using autoencoder networks

2021

Machine learning: science and technology 2(4), 045024 (2021). doi:10.1088/2632-2153/ac1eea

Signal Processing (eess.SP)FOS: Computer and information sciencesAccuracy and precisionComputer Science - Machine LearningComputer scienceddc:621.3FOS: Physical sciences01 natural sciencesSignalMachine Learning (cs.LG)010309 opticsExponential growthArtificial Intelligence0103 physical sciencesFOS: Electrical engineering electronic engineering information engineeringLimit (mathematics)Neural and Evolutionary Computing (cs.NE)Electrical Engineering and Systems Science - Signal Processing010306 general physicsSignal processingArtificial neural networkEstimation theoryComputer Science - Neural and Evolutionary ComputingAutoencoder621.3Human-Computer InteractionPhysics - Data Analysis Statistics and ProbabilityAlgorithmSoftwareData Analysis Statistics and Probability (physics.data-an)Machine Learning: Science and Technology
researchProduct