Search results for "Acetochlor"
showing 3 items of 3 documents
Particle size distributions of currently used pesticides in a rural atmosphere of France
2013
This work presents first data on the particle size distributions of current-used pesticides in the atmosphere. Ambient air samples were collected using a cascade impactor distributed into four size fractions in a rural site of Centre Region (France). Most pesticides were accumulated in the fine (0.1-1 mu m) particle size fraction such as cyprodinil, pendimethalin, fenpropidin, fenpropimorph and spiroxamine. Other pesticides such as acetochlor and metolachlor presented a bimodal distribution with maximum concentrations in the ultrafine (0.03-0.1 mu m) coarse (1-10 mu m) and in the ultrafine fine size ranges, respectively. No pesticides were detected in the size fraction >10 mu m. (C) 2013 El…
Utilization of long duration high-volume sampling coupled to SPME-GC-MS/MS for the assessment of airborne pesticides variability in an urban area (St…
2016
Atmospheric samples have been collected between 14 March and 12 September 2012 on a 2-week basis (15 days of sampling and exchange of traps each 7 days) in Strasbourg (east of France) for the analysis of 43 pesticides. Samples (particle and gas phases) were separately extracted using Accelerated Solvent Extraction (ASE) and pre-concentrated by Solid Phase Micro-Extraction (SPME) before analysis by gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). Four SPME consecutive injections at distinct temperatures were made in order to increase the sensitivity of detection for the all monitored pesticides. Currently used detected pesticides can be grouped in four classes; those used i…
Assessment of two extraction methods to determine pesticides in soils, sediments and sludges. Application to the Túria River Basin.
2014
Pressurized liquid extraction (PLE) and Quick, Easy, Cheap, Effective, Rugged and Safe (QuEChERS) extraction methods were optimized for the simultaneous determination of 50 pesticides in sediment, soils and sewage sludge. For QuEChERS development, several buffers and dispersive solid-phase extraction clean-up (dSPE) sorbents were tested. In the PLE method, several parameters affecting the extraction efficiency, such as organic solvent, amount of sample, cell size, temperature, pressure, static time, number of cycles and % of flush, as well as sorbent used for the on-line clean up, were also evaluated. PLE and QuEChERS were assessed and compared in obtained recoveries (33-89% versus 25-120%)…