Search results for "Adhesion"

showing 10 items of 1165 documents

Endothelialization of a non-woven silk fibroin net for use in tissue engineering: growth and gene regulation of human endothelial cells

2004

Abstract We have previously shown that a biomaterial consisting of a non-woven fibroin net produced from silk (Bombyx mori) cocoons is an excellent scaffolding material for a wide variety of human cells of different tissue types. Endothelialization must take place for a biomaterial to be successful after implantation. Therefore, primary human endothelial cells and the human endothelial cell lines, HPMEC-ST1.6R and ISO-HAS-1, were examined for adherence and growth patterns on the fibroin nets by confocal laser scanning microscopy after vital staining of the cells and by electron microscopy. Endothelial cells adhered and spread along individual fibers of the nets and did not fill the gaps bet…

Materials scienceAngiogenesisBiophysicsNeovascularization PhysiologicFibroinBiocompatible MaterialsBioengineeringBiomaterialsTissue engineeringBombyx moriMaterials TestingAnimalsHumansCells CulturedTissue EngineeringbiologyfungiEndothelial CellsBiomaterialBombyxbiology.organism_classificationCell biologyFibronectinEndothelial stem cellGene Expression RegulationMechanics of MaterialsCell cultureCeramics and Compositesbiology.proteinFibroinsCell Adhesion MoleculesCell DivisionBiomedical engineeringBiomaterials
researchProduct

Fibronectin-mediated endothelialisation of chitosan porous matrices.

2009

Chitosan (Ch) porous matrices were investigated regarding their ability to be colonized by human microvascular endothelial cells (HPMEC-ST1.6R cell line) and macrovascular endothelial cells namely HUVECs. Specifically we assessed if previous incubation of Ch in a fibronectin (FN) solution was effective in promoting endothelial cell (EC) adhesion to Ch matrices with different degrees of acetylation (DAs). Upon FN physiadsorption, marked differences were found between the two DAs investigated, namely DA 4% and 15%. While cell adhesion was impaired on Ch with DA 15%, ECs were able to not only adhere to Ch with DA 4%, but also to spread and colonize the scaffolds, with retention of the EC pheno…

Materials scienceAngiogenesisCell SurvivalBiophysicsNeovascularization PhysiologicBioengineeringBiocompatible MaterialsCell LineBiomaterialsMaterials TestingHumansCell adhesionCell ProliferationCell SizeChitosanbiologyCell growthEndothelial CellsAdhesionFibronectinsEndothelial stem cellFibronectinBiochemistryMechanics of MaterialsCell cultureCeramics and Compositesbiology.proteinBiophysicsPorosityProtein adsorptionBiomaterials
researchProduct

Vascularization and gene regulation of human endothelial cells growing on porous polyethersulfone (PES) hollow fiber membranes.

2004

Abstract Open-cell hollow fibers made of polyethersulfone (PES) manufactured in the absence of solvents with pore diameters smaller than 100 μm were examined for vascularization by human endothelial cells. The goal of this study was to determine whether the 3-D porous character of the PES surface affected human endothelial cell morphology and functions. Freshly isolated human endothelial cells from the skin (HDMEC), from the lung (HPMEC) and from umbilical cords (HUVEC) and two human endothelial cell lines, HPMEC-ST1.6R and ISO-HAS.c1 were added to PES fibers and cell adherence and growth was followed by confocal laser scanning microscopy. Prior coating of PES with gelatin or fibronectin wa…

Materials scienceAngiogenesisPolymersSurface PropertiesCellBiophysicsCell Culture TechniquesNeovascularization PhysiologicBioengineeringBiocompatible MaterialsBiomaterialsTissue engineeringMaterials TestingmedicineCell AdhesionHumansSulfonesCells CulturedCell ProliferationConfluencybiologyTissue EngineeringEndothelial CellsCell DifferentiationAdhesionbody regionsEndothelial stem cellFibronectinmedicine.anatomical_structureMembraneGene Expression RegulationMechanics of MaterialsCeramics and CompositesBiophysicsbiology.proteinhuman activitiesPorosityBiomedical engineeringBiomaterials
researchProduct

Effect of Nanodiamonds on Structure and Durability of Polyethylene Oxide-Based Nanocomposites

2016

Polymer-based nanocomposites containing nanodiamonds (NDs) are attractive multifunctional materials with a growing range of applications. In this work, in the frame of developing completely biocompatible systems, nanocomposites based on polyethylene oxide (PEO) and different amount of NDs have been formulated through melt mixing and fully characterized. In particular, the reinforcement effect of NDs in PEO has been probed through tensile tests, and the rheological response of PEO-based nanocomposites as a function of the nanoparticles amount has been investigated and discussed. The obtained results show that the presence of well-distributed NDs strengthens the mechanical performance of the …

Materials scienceArticle SubjectNanoparticle02 engineering and technology010402 general chemistry01 natural sciencesDurabilityCrystallinitylcsh:Technology (General)Ultimate tensile strengthGeneral Materials ScienceComposite materialPhotodegradationPolyethylene Oxidechemistry.chemical_classificationNanocompositeNanocompositePolymerAdhesion021001 nanoscience & nanotechnologyAccelerated aging0104 chemical sciencesSettore ING-IND/22 - Scienza E Tecnologia Dei Materialichemistrylcsh:T1-995Materials Science (all)0210 nano-technologyNanodiamondJournal of Nanomaterials
researchProduct

Adhesion and Friction Forces between Spherical Micrometer-Sized Particles

1999

An experimental setup, based on the principles of atomic force microscopy (AFM), was used to measure directly the adhesion and rolling-friction forces between individual silica microspheres of radii between 0.5 and 2.5 \ensuremath{\mu}m. It showed that the linear dependence of the pull-off force on the particle radius is still valid for micron-sized particles. Rolling-friction forces between silica microspheres were measured for the first time by combining AFM methods and optical microscopy: They are $\ensuremath{\sim}100$ times lower than the corresponding adhesion forces.

Materials scienceAtomic force microscopyMeasure (physics)Physics::OpticsGeneral Physics and AstronomyAdhesionMicrospherelaw.inventionMicrometreParticle radiusOptical microscopelawbiological sciencesComposite materialPhysical Review Letters
researchProduct

Software-supported image quantification of angiogenesis in an in vitro culture system: application to studies of biocompatibility

2002

Healing of soft tissue trauma and bone discontinuities following implantation involves acute inflammatory reactions and the formation of blood vessels (angiogenesis). During angiogenesis new capillary vessels arise from the existing vasculature. Endothelial cells (EC) are the major cell type involved in angiogenesis. Corrosion of orthopaedic metallic implant materials (e.g. CoCr alloys) can cause locally high concentrations of heavy metal ions in the peri-implant tissues. Some divalent metal ions (Co2+, Ni2+, Zn2+) lead to the activation of EC in vitro. Upon exposure to these ions. EC release cytokines and chemokines and increase the expression of cell surface adhesion molecules, which repr…

Materials scienceBiocompatibilityEndotheliumAngiogenesisBiophysicsNeovascularization PhysiologicBiocompatible MaterialsBioengineeringInflammationBiomaterialsNeovascularizationAlloysImage Processing Computer-AssistedmedicineHumansCells CulturedCell adhesion moleculeMicrocirculationCobaltFluoresceinsIn vitromedicine.anatomical_structureMechanics of MaterialsCeramics and CompositesBiophysicsEndothelium Vascularmedicine.symptomWound healingSoftwareBiomedical engineeringBiomaterials
researchProduct

New generation super alloy candidates for medical applications: Corrosion behavior, cation release and biological evaluation

2014

Three super alloy candidates (X1 CrNiMoMnW 24-22-6-3-2 N, NiCr21 MoNbFe 8-3-5 AlTi, CoNiCr 35-20 Mo 10 BTi) for a prolonged contact with skin are evaluated in comparison with two reference austenitic stainless steels 316L and 904L. Several electrochemical parameters were measured and determined (E(oc), E(corr), i(corr), b(a), b(c), E(b), R(p), E(crev) and coulometric analysis) in order to compare the corrosion behavior. The cation release evaluation and in vitro biological characterization also were performed. In terms of corrosion, the results reveal that the 904L steels presented the best behavior followed by the super austenitic steel X1 CrNiMoMnW 24-22-6-3-2 N. For the other two super a…

Materials scienceBiocompatible MaterialsBioengineeringElectrochemistryCell LineCorrosionBiomaterialsCoulometryMiceCationsMaterials TestingAlloysElectrochemistryHuman Umbilical Vein Endothelial CellsAnimalsHumansNichromeCorrosion behaviorCell ProliferationAusteniteTumor Necrosis Factor-alphaExtraction (chemistry)MetallurgyIntercellular Adhesion Molecule-1Stainless SteelCorrosionSuperalloyMetalsMechanics of MaterialsHeLa CellsMaterials Science and Engineering: C
researchProduct

Modification of human platelet adhesion on biomaterial surfaces by protein preadsorption under static and flow conditions.

2004

Biomaterial-induced thrombosis remains one of the main complications of vascular implant devices. Preadsorbed proteins on the biomaterial/blood interface will modify the adhesion and activation of platelets (PTLs) during the initial contact-phase. Our results clearly show that PTL-adherence on biomaterials is influenced not only by protein preadsorption, but also by flow conditions. The covalent coating of TCPS and glass by phosphorylcholine (PC) induces a significant decrease of PTL adhesion but leads to a slight, but nevertheless significant activation of PTL, which was detected by the induction of P-selectin expression using FACS analysis. Methodologically, the visualization of PTL adhes…

Materials scienceBiomedical EngineeringBiophysicschemistry.chemical_elementBioengineeringBiocompatible MaterialsCalciumIn Vitro TechniquesBiomaterialsBlood cellPlatelet AdhesivenessIn vivoMaterials TestingmedicineHumansPlateletPhosphorylcholineBiomaterialThrombosisAdhesionBlood ProteinsFlow CytometryPlatelet ActivationBiomechanical PhenomenaBlood Vessel ProsthesisP-Selectinmedicine.anatomical_structurechemistryembryonic structuresImmunologyHemorheologyBiophysicsAdsorptionProtein adsorptionJournal of materials science. Materials in medicine
researchProduct

Repair bond strength of bulk fill composites after different adhesion protocols

2019

Background Repairs in composite resin restorations are common procedures in clinical practice. Many surface treatment options have been proposed to improve the adhesion between the old and new composite. The objective of this study was to evaluate the microtensile bond strength of repairs performed on aged bulk fill and conventional composites after different adhesion protocols. Material and methods First, 84 specimens (8x8x4 mm3) of a microhybrid composite and a high-viscosity bulk fill composite were prepared and aged. Afterward, they received a mechanical surface treatment by means of abrasion with a diamond bur, followed by division into six groups according to the adhesion protocol emp…

Materials scienceBond strengthAbrasion (mechanical)Research0206 medical engineeringComposite numberBulk fill030206 dentistry02 engineering and technologyAdhesion:CIENCIAS MÉDICAS [UNESCO]020601 biomedical engineeringSilaneOperative Dentistry and Endodontics03 medical and health scienceschemistry.chemical_compound0302 clinical medicinechemistryUNESCO::CIENCIAS MÉDICASAdhesiveComposite materialGeneral DentistryPhosphoric acid
researchProduct

Comparison of the friction and wear properties of titanium and oxidised titanium in dry sliding against sintered high speed steel HS18-0-1 and agains…

2005

Abstract The paper presents the results of conformal pin-on-disc tribological tests concerning the hard oxidised zone, α-Ti(O), created at the surface of a titanium specimens sliding against the sintered and hardened up to 850 HV30, Grade T1 high speed steel (HS18-0-1) counterspecimens. Comparison with the results obtained for the tests performed against hardened up to 620 HV30 C45 carbon steel counterspecimens has been done. Testing was carried out at room temperature and at unlubricated conditions. After tests the structures and compositions of the worn surfaces and wear debris were a subject of LOM, SEM observations and X-ray microanalyses. In comparison with the baseline—the Ti/T1 HSS c…

Materials scienceCarbon steelMetallurgyAbrasiveMetals and Alloyschemistry.chemical_elementAdhesionengineering.materialTribologyIndustrial and Manufacturing EngineeringComputer Science ApplicationsWear resistancechemistryModeling and SimulationCeramics and CompositesengineeringComposite materialA titaniumTitaniumHigh-speed steelJournal of Materials Processing Technology
researchProduct