Cost analysis of the facilities deterioration in wastewater treatment plants: A dynamic approach
2019
Abstract The implementation of the Directive 91/271 / CEE resulted in the proliferation of new Wastewater Treatment Plants (WWTPs) all around Europe. These facilities, which are compound by a wide range of assets (civil works, electromechanical equipment, pipelines, etc.), are ageing and deteriorating having an impact on the efficiency of the process. It is founded that repairs and corrective maintenance costs have increased in the last years, due to the deterioration process. Therefore, the aim of the present study is to focus on the cost effects of the deterioration process of the facilities in different wastewater treatment technologies. The analysis of these impacts will allow the opera…
The fouling phenomenon in membrane bioreactors: Assessment of different strategies for energy saving
2013
Abstract Membrane fouling represents one of the major issues for a membrane bioreactor (MBR). Membrane fouling and high aeration requirements (for inducing shear stress to limit fouling) make MBR operation economically demanding due to high energy costs. Although several studies on MBR fouling have been performed, comprehensive knowledge on how to reduce membrane fouling and consequently save energy is still lacking. An integrated mathematical model for MBR is applied to a University of Cape Town membrane bioreactor with the final aim to reduce the energy costs. In particular, the influence of the aeration intensity, the duration of filtration/backwashing cycles, and the number of membrane …
Expert control of DO in the aerobic reactor of an activated sludge process
2001
Abstract An expert control structure is proposed for the control of dissolved oxygen (DO) in a Nitrification Denitrification Biological Excess Phosphorus Removal (NDBEPR) plant to account for the several processes that are influenced by the DO concentration in the aerator. In the scheme a supervisory fuzzy controller determines the set point of an inner DO control loop where an Adaptive Robust Generic Model Control (ARGMC) controller is used. The fuzzy supervisory control has a hierarchical structure. Off-line measurements of biological parameters of influent and effluent streams can be used to periodically update the set points of the fuzzy controllers. The complete control scheme has been…
DSC: software tool for simulation-based design of control strategies applied to wastewater treatment plants.
2011
This paper presents a computer tool called DSC (Simulation based Controllers Design) that enables an easy design of control systems and strategies applied to wastewater treatment plants. Although the control systems are developed and evaluated by simulation, this tool aims to facilitate the direct implementation of the designed control system to the PC of the full-scale WWTP (wastewater treatment plants). The designed control system can be programmed in a dedicated control application and can be connected to either the simulation software or the SCADA of the plant. To this end, the developed DSC incorporates an OPC server (OLE for process control) which facilitates an open-standard communic…
SCREENING OF CHEMICAL SPILL RISKS TO MUNICIPAL SEWAGE TREA TMENT PLANTS
1994
Seven operational mishaps were specified on the basis of a questionnaire on wastewater treatment plants, some of them large. In this study a process was developed for screening the chemical spill risks to municipal biological sewage treatment plant. Data on wastewater treatment processes, potential spill sources and chemical properties were combined to determine the threshold chemical quantities which may inhibit the removal of carbonaceous material, prevent nitrification and methanogenesis, cause sludge contamination or lead to the aeration capacity being exceeded. Two sewage treatment plants and eleven industrial sites were chosen for field studies. The influence of spill duration and mai…
Energy saving in the aeration process by fuzzy logic control
1998
An aeration fuzzy logic based control system has been developed and tested in the main aerobic reactor of a BARDENPHO process pilot plant. This system has been compared with two ordinary aeration process controllers: one- and two-aeration-level on/off controllers. Energy savings of about 40% over the one-level on/off controller and a more stable closed-loop response have been obtained. Thus, an improvement of about 60% in average deviation can be accomplished by the use of an AFLBC.
Removal and fate of endocrine disruptors chemicals under lab-scalepostreatment stage. Removal assessment using light, oxygen and microalgae
2013
[EN] The aim of this study was to assess the effect of light, oxygen and microalgae on micropollutants removal. The studied micropollutants were 4-(1,1,3,3-tetramethylbutyl)phenol (OP), technical-nonylphenol (t-NP), 4-n-nonylphenol (4-NP), Bisphenol-A (BPA). In order to study the effect of the three variables on the micropollutants removal, a factorial design was developed. The experiments were carried out in four batch reactors which treated the effluent of an anaerobic membrane bioreactor. The gas chromatography mass spectrometry was used for the measurement of the micropollutants. The results showed that light, oxygen and microalgae affected differently to the degradation ratios of each …
Weathering of gasification and grate bottom ash in anaerobic conditions
2009
Abstract The effect of anaerobic conditions on weathering of gasification and grate bottom ash were studied in laboratory lysimeters. The two parallel lysimeters containing the same ash were run in anaerobic conditions for 322 days, after which one was aerated for 132 days. The lysimeters were watered throughout the study and the quality of leachates and changes in the binding of elements into ash were observed. The results show that organic carbon content and initial moisture of ashes are the key parameters affecting the weathering of ashes. In the grate ash the biodegradation of organic carbon produced enough CO 2 to regulate pH. In contrast the dry gasification ash, containing little org…
A supervisory control system for optimising nitrogen removal and aeration energy consumption in wastewater treatment plants
2002
A fuzzy logic supervisory control system for optimising nitrogen removal and aeration energy consumption has been developed. This control system allows optimising and controlling the dissolved oxygen (DO) concentration in the aerobic reactors, the blowers discharge pressure and the effluent ammonia and nitrate concentrations. DO is controlled by adjusting control valve opening and blower discharge pressure is controlled by modifying rotational speed of the blowers. Optimum nitrification/denitrification is achieved by modifying the DO set point in the last aerobic reactor and the internal recirculation. This system has been tested by simulation in a Bardenpho process using the Activated Slud…
Nitrous oxide from integrated fixed-film activated sludge membrane bioreactor: Assessing the influence of operational variables
2017
The influence of the main operational variables on N2O emissions from an Integrated Fixed Film Activated Sludge University of Cape Town membrane Bioreactor pilot plant was studied. Nine operational cycles (total duration: 340 days) were investigated by varying the value of the mixed liquor sludge retention time (SRT) (Cycles 1â3), the feeding ratio between carbon and nitrogen (C/N) (Cycles 4â6) and simultaneously the hydraulic retention time (HRT) and the SRT (Cycles 7â9). Results show a huge variability of the N2O concentration in liquid and off-gas samples (ranged from 10â1μg N2O-N Lâ1to 103μg N2O-N Lâ1). The maximum N2O concentration (1228 μg N2O-N Lâ1) in the off-gas sa…