Search results for "Aging"

showing 10 items of 10496 documents

Magnesium and Type 2 Diabetes: An Update

2015

The link between magnesium (Mg) deficiency and type 2 diabetes mellitus is well known. Type 2 diabetes is frequently associated with both extracellular and intracellular Mg deficits. A chronic latent Mg deficit or an overt clinical hypomagnesaemia is common in subjects with type 2 diabetes, especially in those with poorly controlled glycemic profiles. Insulin and glucose are important regulators of Mg metabolism. Intracellular Mg plays a key role in regulating insulin action, insulin-mediated-glucose-uptake and vascular tone. Reduced intracellular Mg concentrations result in a defective tyrosine-kinase activity, postreceptorial impairment in insulin action and worsening of insulin resistanc…

medicine.medical_specialtySettore MED/09 - Medicina InternaDiabetes riskbusiness.industryInsulinmedicine.medical_treatmentType 2 Diabetes MellitusType 2 diabetesmedicine.diseaseInsulin resistanceEndocrinologyInternal medicineDiabetes mellitusmedicineMetabolic syndromebusinessMagnesium Diabetes Metabolic syndrome Hypertension Insulin resistance Inflammation Aging Endothelium Hypomagnesaemia MetabolismGlycemicInternational Journal of Diabetes and Clinical Research
researchProduct

SIUMB guidelines and recommendations for the correct use of ultrasound in the management of patients with focal liver disease

2019

The present document describes the SIUMB (Italian Society of Ultrasound in Medicine and Biology) guidelines for the use of ultrasound in the management of focal liver disease. The aim of the paper is to provide a clinical practice guideline for Italian physicians who are approaching the ultrasound study of a focal liver lesion. In particular, these guidelines provide simple indications, recommendations and general practice advices for the correct use of contrast-enhanced ultrasound (CEUS) in this scenario. They represent the SIUMB position of the ultrasound role in the diagnostic flow charts of the principal focal liver lesions, and are in agreement with other, previously published national…

medicine.medical_specialtySettore MED/09 - Medicina InternaHepatocellular carcinomaContrast enhanced ultrasoundCholangiocellular carcinoma; Contrast enhanced ultrasound; Focal nodular hyperplasia; Hemangioma; Hepatocellular carcinoma; MetastasisContrast MediaMetastasiCholangiocellular carcinoma030218 nuclear medicine & medical imagingMetastasis03 medical and health sciencesLiver disease0302 clinical medicineFocal nodular hyperplasiaInternal MedicineHumansMedicineRadiology Nuclear Medicine and imagingMedical physicsUltrasonographyUltrasound studybusiness.industryLiver NeoplasmsUltrasoundFocal nodular hyperplasiaGeneral MedicineGuidelinemedicine.diseaseClinical PracticeLiverLiver lesionOriginal Article030211 gastroenterology & hepatologyCholangiocellular carcinoma; Contrast enhanced ultrasound; Focal nodular hyperplasia; Hemangioma; Hepatocellular carcinoma; Metastasis; Contrast Media; Humans; Liver; Liver Neoplasms; UltrasonographybusinessHemangiomaContrast-enhanced ultrasound
researchProduct

Magnesium and hypertension in old age

2021

Hypertension is a complex condition in which various actors and mechanisms combine, resulting in cardiovascular and cerebrovascular complications that today represent the most frequent causes of mortality, morbidity, disability, and health expenses worldwide. In the last decades, there has been an exceptional amount of experimental, epidemiological, and clinical studies confirming a close relationship between magnesium deficit and high blood pressure. Multiple mechanisms may help to explain the bulk of evidence supporting a protective effect of magnesium against hypertension and its complications. Hypertension increases sharply with advancing age, hence older persons are those most affected…

medicine.medical_specialtySettore MED/09 - Medicina InternaMagnesium supplementationchemistry.chemical_elementBlood Pressurelcsh:TX341-641Review030204 cardiovascular system & hematologyHypertension riskAging Cardiovascular disease03 medical and health sciences0302 clinical medicineInsulin resistancecardiovascular diseaseMagnesium deficiency (medicine)EpidemiologymedicineHumansMagnesium030212 general & internal medicineMicronutrientsIonIntensive care medicineAgedAged 80 and overNutrition and Dieteticsbusiness.industryMagnesiumagingInsulin resistanceFeeding Behaviormedicine.diseaseDietBlood pressurechemistryClose relationshipDietary SupplementsHypertensionionsbusinessMagnesium Deficiencylcsh:Nutrition. Foods and food supplyFood ScienceSupplement
researchProduct

Inverse association between type 2 diabetes and aortic root dimension in hypertensive patients

2017

Background Some data support the concept that aortic root diameter (ARD) in hypertension may be regarded as a marker of subclinical organ damage. The impact of type 2 diabetes mellitus (DM) on cardiac structure and function is known, although the relationship between DM and ARD is not clear. The aim of our study was to evaluate the influence of DM on ARD in hypertensive patients. Methods We enrolled 1693 hypertensive patients (aged 63.7 ± 9.6 years). The population was divided into two groups: the first one with DM (n = 747) and the second one without DM (n = 946). ARD was measured by echocardiography at level of Valsalva's sinuses using echocardiography M-mode tracings. It was considered a…

medicine.medical_specialtySettore MED/09 - Medicina InternaPopulationType 2 diabetes030204 cardiovascular system & hematologyDoppler imagingType 2 diabeteSettore MED/13 - Endocrinologia03 medical and health sciences0302 clinical medicineBayesian multivariate linear regressionInternal medicinemedicine030212 general & internal medicineeducationSubclinical infectionBody surface areaeducation.field_of_studybusiness.industryConfoundingType 2 Diabetes Mellitusmedicine.diseaseCardiovascular riskSettore MED/11 - Malattie Dell'Apparato CardiovascolareEndocrinologyEchocardiographyHypertensionCardiologyCardiology and Cardiovascular MedicinebusinessAortic root diameter
researchProduct

The Interplay between Magnesium and Testosterone in Modulating Physical Function in Men

2014

The role of nutritional status as determinant of successful aging is very well recognized. There is recent evidence that nutrition may exert its beneficial effects through the modulation of the hormonal anabolic milieu. Under-nutrition and anabolic hormonal deficiency frequently coexist in older individuals determining an increased risk of mobility impairment and adverse outcomes. Mineral dietary assessment has received attention as key component of the nutritional modulation of anabolic status and physical performance. There is evidence that several minerals, including magnesium, exert a positive influence on Insulin-like Growth Factor-1 (IGF-1) secretion in both sexes, and Testosterone (T…

medicine.medical_specialtySettore MED/09 - Medicina Internalcsh:RC648-665Successful agingAnabolismEndocrine and Autonomic Systemsbusiness.industryEndocrinology Diabetes and MetabolismPhysiologyTestosterone (patch)Review ArticlePhysical functionmedicine.diseaselcsh:Diseases of the endocrine glands. Clinical endocrinologyMalnutritionEndocrinologyIncreased riskEndocrinologymagnesium testosterone menInternal medicinemedicineObservational studybusinessHormoneInternational Journal of Endocrinology
researchProduct

Anteil des frühen systolischen Flussanstiegs am antegrad fließenden Gesamtvolumen bei Phasenkontrast-Flussmessungen in Atemanhaltetechnik

2005

Purpose To evaluate the contribution of early systole for the assessment of antegrade aortic flow volume by breath-hold velocity-encoded magnetic resonance (MR) flow measurements. Materials and methods Expiratory breath-hold fast low-angle shot (FLASH) phase-contrast flow measurements (temporal resolution tRes 61 msec, shared phases) perpendicular to the proximal ascending aorta and short axis true fast imaging with steady-state precession (TrueFISP) cine MR ventriculometry (tRes 34.5 msec) were performed in ten healthy male volunteers on a 1.5 T MR system (Sonata, Siemens Medical Solutions). Antegrade aortic flow volume (AFV) and left ventricular stroke volume (LV-SV) were evaluated using …

medicine.medical_specialtyShort axisVentricular functionmedicine.diagnostic_testbusiness.industryPhase contrast microscopySignificant differenceMagnetic resonance imagingBlood flowlaw.inventionSurgeryVolume (thermodynamics)Flow (mathematics)Paired sampleslawmedicine.arteryAscending aortaLeft ventricular Stroke volumeMedicineRadiology Nuclear Medicine and imagingSystolebusinessNuclear medicineRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Multi-spectral skin imaging by a consumer photo-camera

2010

The possibilities to perform multi-band spectral imaging by means of a consumer color camera without external filters have been studied. Images at up to 6 spectral bands may be extracted from a single color image after appropriate signal processing. The proposed technique was tested in pilot measurements of in-vivo skin hemoglobin maps and laser-excited autofluorescence images.

medicine.medical_specialtySignal processingMaterials sciencebusiness.industryColor imagePhysics::Medical PhysicsHyperspectral imagingSpectral bandsLaserSpectral imaginglaw.inventionImaging spectroscopyAutofluorescenceOpticslawComputer Science::Computer Vision and Pattern RecognitionmedicinebusinessSPIE Proceedings
researchProduct

High Dynamic Range Spectral Imaging Pipeline For Multispectral Filter Array Cameras

2017

Spectral filter arrays imaging exhibits a strong similarity with color filter arrays. This permits us to embed this technology in practical vision systems with little adaptation of the existing solutions. In this communication, we define an imaging pipeline that permits high dynamic range (HDR)-spectral imaging, which is extended from color filter arrays. We propose an implementation of this pipeline on a prototype sensor and evaluate the quality of our implementation results on real data with objective metrics and visual examples. We demonstrate that we reduce noise, and, in particular we solve the problem of noise generated by the lack of energy balance. Data are provided to the community…

medicine.medical_specialtySimilarity (geometry)Computer sciencePipeline (computing)Multispectral imageComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONspectral imaging02 engineering and technology[ SPI.SIGNAL ] Engineering Sciences [physics]/Signal and Image processinglcsh:Chemical technology01 natural sciencesBiochemistryArticleAnalytical Chemistry010309 optics[SPI]Engineering Sciences [physics]Color gel0103 physical sciences[ INFO.INFO-TI ] Computer Science [cs]/Image Processing0202 electrical engineering electronic engineering information engineeringmedicine[ SPI ] Engineering Sciences [physics]Computer visionlcsh:TP1-1185Electrical and Electronic EngineeringInstrumentationHigh dynamic rangeComputingMilieux_MISCELLANEOUSbusiness.industryhigh dynamic rangespectral filter arraysAtomic and Molecular Physics and Opticsspectral imaging; spectral filter arrays; high dynamic range; image databaseSpectral imagingNoiseFilter (video)[INFO.INFO-TI]Computer Science [cs]/Image Processing [eess.IV]020201 artificial intelligence & image processingArtificial intelligencebusiness[SPI.SIGNAL]Engineering Sciences [physics]/Signal and Image processingimage database
researchProduct

Mo2021 Predicting Polyp Histology - Development and Validation of an International Simple Endoscopic Classification of Small Colorectal Polyps Using …

2017

medicine.medical_specialtySimple (abstract algebra)business.industryGastroenterologymedicineRadiology Nuclear Medicine and imagingHistologyRadiologybusinessGastrointestinal Endoscopy
researchProduct

Sentinel Node Identification in Melanoma: Current Clinical Impact, New Emerging SPECT Radiotracers and Technological Advancements. An Update of the L…

2020

Background: Melanoma is the most lethal skin cancer with a mortality rate of 262 cases per 100.000 cases. The sentinel lymph node (SLN) is the first lymph node draining the tumor. SLN biopsy is a widely accepted procedure in the clinical setting since it provides important prognostic information, which helps patient management, and avoids the side effects of complete lymph node dissection. The rationale of identifying and removing the SLN relies on the low probability of subsequent metastatic nodes in case of a negative histological exam performed in the SLN. Discussion: Recently, new analytical approaches, based on the evaluation of scintigraphic images are also exploring the possibility …

medicine.medical_specialtySingle Photon Emission Computed Tomography Computed TomographySkin NeoplasmsSentinel lymph nodeSingle-photon emission computed tomographySentinel lymph node biopsyhybrid imagingBiopsymedicineHumansRadiology Nuclear Medicine and imagingsentinel lymph node biopsyMelanomaLymph nodePharmacology99mTc-Tilmanoceptmedicine.diagnostic_testbusiness.industryMelanomaSPECT/CTSentinel nodePrognosismedicine.disease99mTc-colloids; 99mTc-Tilmanocept; Hybrid imaging; Melanoma; Sentinel lymph node biopsy; SPECT/CT; Humans; Lymphoscintigraphy; Melanoma; Prognosis; Radiopharmaceuticals; Sentinel Lymph Node; Single Photon Emission Computed Tomography Computed Tomography; Skin NeoplasmsDissectionHybrid imagingmedicine.anatomical_structure99mTc-colloidsRadiologyRadiopharmaceuticalsSentinel Lymph NodeSkin cancerbusinessLymphoscintigraphyCurrent Radiopharmaceuticals
researchProduct